Absolute calibration of an analog InSb detector based on multimode spatial correlation of correlated photons

Xia Maopeng, Jianjun Li, Gao Dongyang, Youbo Hu, Sheng Wen-Yang, Pang Wei-Wei, Zheng Xiao-Bing

Published Jan 1, 2015• 1 citation
Publisher

Abstract

Absolute calibration can be realized by means of correlation photon which is generated by the parametric down conversion. The main difficulty lies in obtaining correlation information about photon flux when this method is applied to analog detector calibration process. A novel method of processing the photocurrent on the basis of detecting multimode spatial correlation is proposed. By converting the charge quantity contained in the photocurrent detected in a certain time interval into the photon counting, and by using double channels balance detection and measuring mean photon counts of each model to correct the dual channels fluctuations, the high accuracy calibration of quantum efficiency can be achieved. The photon fluxes of two channels are balanced by inserting an adjustable attenuator in one optical path. The cross section of pumping beam is comparable to the detection area to ensure three-wave colinearity, and the coherent area of the correlation photons is obtained by measuring pump beam waist and lens focus length. With the known detection area, coherence time and coherence area, the average photon number of each mode is computed. This process should be performed under the average photon number of each mode as a reference which could be used for the proportional scaling of equivalent photons of two channels. Based on this new approach, the absolute power responsivity of an InSb detector is calibrated at 3390 nm with correlated photon pairs at 631 and 3390 nm. The calibration procedure and experiments are described and the uncertainty of this method is analyzed. The results show a relative combination uncertainty of about 7.785% for this calibration method, which agrees well with the result independently obtained in the national photoelectronic metrology laboratory within a relative difference of about 3.6%. This result verifies that the quantum efficiency of an analog detector can be calibrated by the correlated photon method, which has potential applications in highly accurate radiometric calibration without external standards.

DOI
10.7498/aps.64.240601

Related papers

Quantum efficiency calibration of opto-electronic detector by means of correlated photons method

李健军 Jian-jun LI, 郑小兵 Xiaobing Zheng, Yunjun Lu +2 more

A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal.An absolute calibration system of detector quantum efficiency is performed.And its principle and experimental setup are introduced.A continuouswave (CW) ultraviolet (351 nm), diode-pumped, frequency-doubled, and solid-state laser is used to pump BBO crystal.The quantum efficiencies of the photomultiplier at 633, 702, and 789 nm are measured respectively.The coincidence peaks are observed using coincidence circuit.Some measurement factors including the filter bandwidth of trigger channel, the detector position alignment and polarization of the pump light are analyzed.The uncertainties of this calibration method are also analyzed, and the relative uncertainties of total calibration are less than 5.8%.The accuracy of this method could be improved in the future.

Chinese Optics Letters•Jan 1, 2008•5 citations

Investigation of absolute measurement in quantum efficiency of photoelectric detectors by means of correlated photons

Yu Feng, Xiaobing Zheng, Yanli Qiao +1 more

There are two general methods for radiometric calibration of detectors. One is based on radiometric sources and the other is based on detectors. Because two methods need to establish primary standard of high precision and transfer chain of standard, the precision of standard will be reduced by extension of the chain. An absolute calibration of quantum efficiency of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal. Generation mechanism of SPDC is interpreted with theories of quantum mechanics and classical theories. The theory of calibration based correlated photons are demonstrated. The project for proof of principle of absolute calibration of quantum efficiency of radiometric detectors is given in this paper. Comparing with traditional methods, the advantages of it are pointed out. A scheme using to calibrate quantum efficiency of infrared detectors is described here. The measurement of spatial and spectral response of detectors is mentioned too.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 23, 2006•0 citations

Measurement of the Quantum Efficiency of Analog Detectors in the Parametric Down-Conversion Field

T. I. Novikova, A.A. Leontyev, G. Kh. Kitaeva

Approaches to the standard-free calibration of the quantum efficiency of a wide class of analog detectors based on the measurement of statistical characteristics of fields generated by parametric down-conversion are analyzed. General expressions are obtained for the noise reduction factor of the difference photocurrent and for the covariance of photocurrents in the signal and idler channels that take into account the possibility of strong fluctuations in the amplitudes of single-photon response functions of the detectors used. It is shown that the measurement of the noise reduction factor of the difference photocurrent using detectors that cannot operate in the photon counting mode is on its own insufficient to directly characterize the level of two-mode squeezing in the down-conversion field and to determine the quantum efficiency of photosensitive elements without additional calibration procedures. A method to determine the quantum efficiency of such detectors based on measuring the dependence of the normalized covariance of photocurrents on the parametric gain is proposed.

Journal of Experimental and Theoretical Physics Letters•Sep 1, 2022•3 citations

Detection of multimode spatial correlation in PDC and application to the absolute calibration of a CCD camera

G. Brida, Ivo Pietro Degiovanni, Marco Genovese +2 more

We propose and demonstrate experimentally a new method based on the spatial entanglement for the absolute calibration of analog detectors. The idea consists on measuring the sub-shot-noise intensity correlation between two branches of parametric down conversion, containing many pairwise correlated spatial modes. We calibrate a scientific CCD camera and a preliminary evaluation of the uncertainty indicates the metrological interest of the method.

arXiv:1005.2937•Optics Express•Sep 14, 2010•73 citations

Modified Klyshko method for an analog detector calibration

Pavel A. Prudkovskii, Daniil A. Safronenkov, G. Kh. Kitaeva

We extend the absolute quantum efficiency (QE) calibration method, previously used only for photon counters, to analog detectors with a high dispersion of single-photon responses. Our approach is demonstrated on a reference-free measurement of a photomultiplier tube (PMT) cathode QE with 4% relative uncertainty. It involves not only measuring the biphoton field correlation function, but also a special approximation of the distribution of detector readings in order to determine the average number of photoelectrons and the average charge corresponding to a single photoelectron. Results of the calibration were verified in an independent experiment; the numbers of incident photons detected by the PMT and a single-photon counter are in good agreement.

Optics Letters•Sep 2, 2022•10 citations

Research in absolute calibration of single photon detectors by means of correlated photons

Yu Feng, Xiaobing Zheng, Jianjun Li +1 more

There are two general methods in radiometric calibration of detectors, one is based on radiation sources and the other based on detectors. Because the two methods need to establish a primary standard of high precision and a transfer chain, precision of the standard will be reduced by extension of the chain. A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal, without needing transfer chain. Using 351.1-nm output of a tunable laser to pump 'beta'-barium borate (BBO) crystal, an absolute calibration experimental system of single photon detectors based on correlated photons is performed. The quantum efficiency of photomultiplier (PMT) at 702.2 nm is measured by the setup. Advantages of this method over traditional methods are also pointed out by comparison.

Chinese Optics Letters•Jun 10, 2006•1 citation
Absolute calibration can be realized by means of correlation photon which is generated by the parametric down conversion. The main difficulty lies in obtaining correlation information about photon flux when this method is applied to analog detector calibration process. A novel method of processing the photocurrent on the basis of detecting multimode spatial correlation is proposed. By converting the charge quantity contained in the photocurrent detected in a certain time interval into the photon counting, and by using double channels balance detection and measuring mean photon counts of each model to correct the dual channels fluctuations, the high accuracy calibration of quantum efficiency can be achieved. The photon fluxes of two channels are balanced by inserting an adjustable attenuator in one optical path. The cross section of pumping beam is comparable to the detection area to ensure three-wave colinearity, and the coherent area of the correlation photons is obtained by measuring pump beam waist and lens focus length. With the known detection area, coherence time and coherence area, the average photon number of each mode is computed. This process should be performed under the average photon number of each mode as a reference which could be used for the proportional scaling of equivalent photons of two channels. Based on this new approach, the absolute power responsivity of an InSb detector is calibrated at 3390 nm with correlated photon pairs at 631 and 3390 nm. The calibration procedure and experiments are described and the uncertainty of this method is analyzed. The results show a relative combination uncertainty of about 7.785% for this calibration method, which agrees well with the result independently obtained in the national photoelectronic metrology laboratory within a relative difference of about 3.6%. This result verifies that the quantum efficiency of an analog detector can be calibrated by the correlated photon method, which has potential applications in highly accurate radiometric calibration without external standards.
A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal.An absolute calibration system of detector quantum efficiency is performed.And its principle and experimental setup are introduced.A continuouswave (CW) ultraviolet (351 nm), diode-pumped, frequency-doubled, and solid-state laser is used to pump BBO crystal.The quantum efficiencies of the photomultiplier at 633, 702, and 789 nm are measured respectively.The coincidence peaks are observed using coincidence circuit.Some measurement factors including the filter bandwidth of trigger channel, the detector position alignment and polarization of the pump light are analyzed.The uncertainties of this calibration method are also analyzed, and the relative uncertainties of total calibration are less than 5.8%.The accuracy of this method could be improved in the future.
There are two general methods for radiometric calibration of detectors. One is based on radiometric sources and the other is based on detectors. Because two methods need to establish primary standard of high precision and transfer chain of standard, the precision of standard will be reduced by extension of the chain. An absolute calibration of quantum efficiency of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal. Generation mechanism of SPDC is interpreted with theories of quantum mechanics and classical theories. The theory of calibration based correlated photons are demonstrated. The project for proof of principle of absolute calibration of quantum efficiency of radiometric detectors is given in this paper. Comparing with traditional methods, the advantages of it are pointed out. A scheme using to calibrate quantum efficiency of infrared detectors is described here. The measurement of spatial and spectral response of detectors is mentioned too.
Approaches to the standard-free calibration of the quantum efficiency of a wide class of analog detectors based on the measurement of statistical characteristics of fields generated by parametric down-conversion are analyzed. General expressions are obtained for the noise reduction factor of the difference photocurrent and for the covariance of photocurrents in the signal and idler channels that take into account the possibility of strong fluctuations in the amplitudes of single-photon response functions of the detectors used. It is shown that the measurement of the noise reduction factor of the difference photocurrent using detectors that cannot operate in the photon counting mode is on its own insufficient to directly characterize the level of two-mode squeezing in the down-conversion field and to determine the quantum efficiency of photosensitive elements without additional calibration procedures. A method to determine the quantum efficiency of such detectors based on measuring the dependence of the normalized covariance of photocurrents on the parametric gain is proposed.
We extend the absolute quantum efficiency (QE) calibration method, previously used only for photon counters, to analog detectors with a high dispersion of single-photon responses. Our approach is demonstrated on a reference-free measurement of a photomultiplier tube (PMT) cathode QE with 4% relative uncertainty. It involves not only measuring the biphoton field correlation function, but also a special approximation of the distribution of detector readings in order to determine the average number of photoelectrons and the average charge corresponding to a single photoelectron. Results of the calibration were verified in an independent experiment; the numbers of incident photons detected by the PMT and a single-photon counter are in good agreement.
There are two general methods in radiometric calibration of detectors, one is based on radiation sources and the other based on detectors. Because the two methods need to establish a primary standard of high precision and a transfer chain, precision of the standard will be reduced by extension of the chain. A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal, without needing transfer chain. Using 351.1-nm output of a tunable laser to pump 'beta'-barium borate (BBO) crystal, an absolute calibration experimental system of single photon detectors based on correlated photons is performed. The quantum efficiency of photomultiplier (PMT) at 702.2 nm is measured by the setup. Advantages of this method over traditional methods are also pointed out by comparison.