Superconductor Science and Technology

Sensitivity of high temperature superconducting Josephson detectors at millimetre-wave band

Jianfang Chen, Y. Kurigata, Huabing Wang, Koji Nakajima, Takashi Yamashita, Peiheng Wu

Published Nov 5, 2003• 8 citations
Publisher

Abstract

Sensitivity of high temperature superconducting (HTS) Josephson detectors at millimetre-wave band has been studied in detail. YBCO grain boundary Josephson junctions with the normal-state resistance ( R N ) around 1 Ω and I C R N product of less than 2 mV have been fabricated for this study, where I C is the critical current of the junction. A Gunn oscillator at the frequency of 98 GHz together with a set of calibrated attenuators with a total attenuation of 90 dB are used as a signal source. A quasi-optical system, which consists of a wideband planar log-periodic antenna encompassing the junction, parabolic mirrors and a hyperhemispherical silicon lens, has been used as an effective coupling system. Sensitivity increases with I C R N . Using a junction with I C R N of 300 µV, a sensitivity of about 9000 V W −1 has been obtained, which is higher than that of the Schottky diode detectors at the same frequency band and demonstrates that the HTS Josephson detectors are very sensitive at millimetre-wave band.

DOI
10.1088/0953-2048/16/12/015

Related papers

Dynamic Range of High Temperature Superconducting Josephson Detecting Systems at Millimeter-Wave Band

J. Chen, P. Wu, Kiyotaka Nakajima +1 more

YBCO grain boundary Josephson junctions (GBJJ's), with the normal-state resistance (R/sub N/) around 1 /spl Omega/ and I/sub C/R/sub N/ product of less than 2 mV at 45 K, where I/sub C/ is the critical current of the junction, are used to study the dynamic range of high temperature superconducting (HTS) Josephson detecting systems at millimeter-wave band. A compact pulse tube cryocooler (PTC), or a liquid helium cryostat (LHC), or a liquid nitrogen cryostat (LNC) provides the necessary low temperature environment for the operation, while Gunn oscillators together with doubler generate signals at the frequencies of 50, 98, 196 GHz whose amplitude can be adjusted by a series of calibrated attenuators. By changing the junction parameters, operating frequencies, and the cryocooler or cryostat, we have carefully looked at the dynamic range of the system. For a measuring channel bandwidth of 1 Hz, the dynamic range is around 38 dB which is determined basically by the preamplifier. This indicates that the PTC does not introduce excess noise compared with other kinds of cryostats such as LHC's or LNC's. A measuring channel bandwidth up to 1 MHz can be helpful if fast measurements are needed.

IEEE Transactions on Applied Superconductivity•Jun 1, 2005•6 citations

Wideband frequency metrology using high temperature superconducting Josephson junctions

Jian Chen, Y. Kurigata, Huabing Wang +3 more

We have studied the responses of high temperature superconducting (HTS) Josephson junctions to monochromatic and polychromatic electromagnetic irradiations from 50 GHz to 4.25 THz. The highest operating frequency and the maximum value of normalized response are shown to be proportional to the I/sub C/R/sub N/ product of the junction, where I/sub C/ and R/sub N/ are the critical current and normal resistance of the junction, respectively. Using a junction with I/sub C/R/sub N/ of 330 /spl mu/V, direct detections of monochromatic irradiations from 76 GHz to 3.1 THz have been obtained, indicating that fast detectors can be realized to cover around 50 : 1 frequency band by operating only one junction at one temperature. Also reported are the superposition of polychromatic signals, as well as some possible applications of the system.

IEEE Transactions on Applied Superconductivity•Jun 1, 2003•21 citations

Submillimeter-wave mixing and noise in HTS Josephson junctions

Michael A. Tarasov, Е. А. Степанцов, Dmitry S. Golubev +6 more

A Josephson quasioptical detector comprising YBaCuO junction on bicrystal MgO substrate, integrated log-periodic Au antenna, MgO extended hyperhemisphere lens attached to the substrate and 1.4 GHz cold amplifier with cold circulator has been designed, fabricated and experimentally studied. We fabricated several integrated Josephson junctions 1-2 /spl mu/m wide which at 4.2 K demonstrate RSJ IV curves with critical currents 100-300 /spl mu/A and normal resistance of 10-20 /spl Omega/. The noise temperature (T/sub N/) at 4.2 K and 330 GHz measured by a hot/cold load method in fundamental mixing mode with external BWO local oscillator brings T/sub N/=1100 K for the junction shunted by low-inductance resistive shunt and T/sub N/=1400 K without shunting. At bath temperatures of 20-40 K the noise temperature was in the range 1500-3000 K, at 50 K the noise temperature was below 2000 K, and at 60-70 K increased over 3000 K in the frequency range 310-586 GHz. The noise temperatures measured in the self-pumping mode vary between 580-2300 K with dc bias in the range 0.1-0.5 mV. The linewidth of Josephson oscillations has been extracted from a selective detector response and IF noise voltage dependence. The measured excess noise can be attributed to shot noise and multiple Andreev reflection in pinholes with Ss'S structure. We observed small subharmonic steps in IV curve and noise dependencies, which are typical for SNS junctions.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•8 citations

Bandwidth and Noise of Submillimeter Wave Cuprate Bicrystal Josephson Junction Detectors

G. A. Ovsyannikov, I. V. Borisenko, K. Y. Constantinian +8 more

Detectors made from superconducting cuprate YBa/sub 2/Cu/sub 3/O/sub x/ bicrystal Josephson junctions (BJJs) on sapphire and NdGaO/sub 3/ substrates have been fabricated and characterized in the frequency band 200-900 GHz. Junctions on sapphire substrates had a normal state resistance R/sub N//spl ap/15-60 /spl Omega/, and I/sub C/R/sub N/ product up to 2.5 mV at T=4.2 K. Junctions on NdGaO/sub 3/ substrates had lower R/sub N/=1-5 /spl Omega/ and I/sub C/R/sub N/=0.4-0.9 mV at T=77 K. Three types of detecting devices have been investigated in both the broadband and the frequency-selective detection modes. One type was patterned with log-periodic antenna, and two others with Pt-metal double-slot antenna designed for a central frequency f=300 GHz and f=400 GHz, respectively. Measurements at f=320 GHz of the reception bandwidth /spl Delta/f for a device with double-slot antenna gave a quality factor Q=f//spl Delta/f/spl ap/10. A low-noise cooled 1-2 GHz bandwidth amplifier enables a better sensitivity in the self-pumping frequency mixing mode, avoiding the 1/f noise. The dependence of the spectral density of noise on voltage was compared to the data for the Josephson emission linewidth obtained by the selective detector response method. Also discussed are measurements at 500 GHz of the NEP values carried out at different experimental conditions.

IEEE Transactions on Applied Superconductivity•Jun 1, 2005•8 citations

Submillimeter-wave Josephson spectroscopy

Michael A. Tarasov, A. Shul’man, O. Yu. Polyanskii +7 more

A Josephson high-temperature superconducting (HTSC) submillimeter-wave spectrometer is designed, built, and experimentally investigated. The integrated detection structure of the spectrometer includes a YBCO Josephson junction on a bicrystalline boundary, a double-slot or log-periodic antenna, and a low-inductance resistive shunt. The selective detector response and the response at an intermediate frequency of 1.4 GHz are measured under the action of a signal in the frequency range 350–1250 GHz. Three methods of spectroscopy are investigated using this setup: 1) a method of Hilbert spectroscopy with processing of the detector response is implemented; 2) it is found that for a wide Josephson line at intermediate frequency (IF) the response has the same form as the detector response, making it possible to obtain a spectrum and the width of the generation line from IF response measurements; 3) for a narrow Josephson line the IF response corresponds to the regime of conversion with self-pumping. A new method is proposed for calculating the emission spectrum. The method consists of simple shift, summation, and subtraction operations. The advantages of the method are simplicity, high sensitivity, and high resolution.

Journal of Experimental and Theoretical Physics Letters•Sep 1, 1999•4 citations

Josephson spectroscopy at submillimetre waves

Michael A. Tarasov, A. Shul’man, N Solopov +8 more

An HTS Josephson spectrometer has been designed, fabricated and experimentally studied. The spectrometer circuit consists of a YBCO bicrystal Josephson junction integrated with a double-slot or log-periodic antenna, connected in parallel with a gold low-inductance shunt. The selective detector response and RF response at intermediate frequency f IF = 1.4 GHz were measured in the signal frequency range f s = 400-1250 GHz and the linewidth of Josephson oscillations (LJO) was determined by using three different methods. (1) The Hilbert spectroscopy approach was used in the processing of the selective detector response. (2) In case of f IF < LJO the detector and RF responses have similar shapes, allowing the spectrum and LJO to be extracted from the RF response and even processing by modified Hilbert spectroscopy. (3) The RF response at f IF > LJO corresponds to the frequency down-conversion in a self-pumped Josephson mixer mode. For the processing of the RF response in the high f IF limit we suggest a novel method that allows extraction of the signal spectrum by means of simple operations: shifting, summing and subtracting. The advantage of the RF response method is in its simplicity and higher sensitivity that allows it to be proposed for spectroscopy applications.

Superconductor Science and Technology•Nov 1, 1999•4 citations
Sensitivity of high temperature superconducting (HTS) Josephson detectors at millimetre-wave band has been studied in detail. YBCO grain boundary Josephson junctions with the normal-state resistance ( R N ) around 1 Ω and I C R N product of less than 2 mV have been fabricated for this study, where I C is the critical current of the junction. A Gunn oscillator at the frequency of 98 GHz together with a set of calibrated attenuators with a total attenuation of 90 dB are used as a signal source. A quasi-optical system, which consists of a wideband planar log-periodic antenna encompassing the junction, parabolic mirrors and a hyperhemispherical silicon lens, has been used as an effective coupling system. Sensitivity increases with I C R N . Using a junction with I C R N of 300 µV, a sensitivity of about 9000 V W −1 has been obtained, which is higher than that of the Schottky diode detectors at the same frequency band and demonstrates that the HTS Josephson detectors are very sensitive at millimetre-wave band.
YBCO grain boundary Josephson junctions (GBJJ's), with the normal-state resistance (R/sub N/) around 1 /spl Omega/ and I/sub C/R/sub N/ product of less than 2 mV at 45 K, where I/sub C/ is the critical current of the junction, are used to study the dynamic range of high temperature superconducting (HTS) Josephson detecting systems at millimeter-wave band. A compact pulse tube cryocooler (PTC), or a liquid helium cryostat (LHC), or a liquid nitrogen cryostat (LNC) provides the necessary low temperature environment for the operation, while Gunn oscillators together with doubler generate signals at the frequencies of 50, 98, 196 GHz whose amplitude can be adjusted by a series of calibrated attenuators. By changing the junction parameters, operating frequencies, and the cryocooler or cryostat, we have carefully looked at the dynamic range of the system. For a measuring channel bandwidth of 1 Hz, the dynamic range is around 38 dB which is determined basically by the preamplifier. This indicates that the PTC does not introduce excess noise compared with other kinds of cryostats such as LHC's or LNC's. A measuring channel bandwidth up to 1 MHz can be helpful if fast measurements are needed.
We have studied the responses of high temperature superconducting (HTS) Josephson junctions to monochromatic and polychromatic electromagnetic irradiations from 50 GHz to 4.25 THz. The highest operating frequency and the maximum value of normalized response are shown to be proportional to the I/sub C/R/sub N/ product of the junction, where I/sub C/ and R/sub N/ are the critical current and normal resistance of the junction, respectively. Using a junction with I/sub C/R/sub N/ of 330 /spl mu/V, direct detections of monochromatic irradiations from 76 GHz to 3.1 THz have been obtained, indicating that fast detectors can be realized to cover around 50 : 1 frequency band by operating only one junction at one temperature. Also reported are the superposition of polychromatic signals, as well as some possible applications of the system.
A Josephson quasioptical detector comprising YBaCuO junction on bicrystal MgO substrate, integrated log-periodic Au antenna, MgO extended hyperhemisphere lens attached to the substrate and 1.4 GHz cold amplifier with cold circulator has been designed, fabricated and experimentally studied. We fabricated several integrated Josephson junctions 1-2 /spl mu/m wide which at 4.2 K demonstrate RSJ IV curves with critical currents 100-300 /spl mu/A and normal resistance of 10-20 /spl Omega/. The noise temperature (T/sub N/) at 4.2 K and 330 GHz measured by a hot/cold load method in fundamental mixing mode with external BWO local oscillator brings T/sub N/=1100 K for the junction shunted by low-inductance resistive shunt and T/sub N/=1400 K without shunting. At bath temperatures of 20-40 K the noise temperature was in the range 1500-3000 K, at 50 K the noise temperature was below 2000 K, and at 60-70 K increased over 3000 K in the frequency range 310-586 GHz. The noise temperatures measured in the self-pumping mode vary between 580-2300 K with dc bias in the range 0.1-0.5 mV. The linewidth of Josephson oscillations has been extracted from a selective detector response and IF noise voltage dependence. The measured excess noise can be attributed to shot noise and multiple Andreev reflection in pinholes with Ss'S structure. We observed small subharmonic steps in IV curve and noise dependencies, which are typical for SNS junctions.
Detectors made from superconducting cuprate YBa/sub 2/Cu/sub 3/O/sub x/ bicrystal Josephson junctions (BJJs) on sapphire and NdGaO/sub 3/ substrates have been fabricated and characterized in the frequency band 200-900 GHz. Junctions on sapphire substrates had a normal state resistance R/sub N//spl ap/15-60 /spl Omega/, and I/sub C/R/sub N/ product up to 2.5 mV at T=4.2 K. Junctions on NdGaO/sub 3/ substrates had lower R/sub N/=1-5 /spl Omega/ and I/sub C/R/sub N/=0.4-0.9 mV at T=77 K. Three types of detecting devices have been investigated in both the broadband and the frequency-selective detection modes. One type was patterned with log-periodic antenna, and two others with Pt-metal double-slot antenna designed for a central frequency f=300 GHz and f=400 GHz, respectively. Measurements at f=320 GHz of the reception bandwidth /spl Delta/f for a device with double-slot antenna gave a quality factor Q=f//spl Delta/f/spl ap/10. A low-noise cooled 1-2 GHz bandwidth amplifier enables a better sensitivity in the self-pumping frequency mixing mode, avoiding the 1/f noise. The dependence of the spectral density of noise on voltage was compared to the data for the Josephson emission linewidth obtained by the selective detector response method. Also discussed are measurements at 500 GHz of the NEP values carried out at different experimental conditions.
A Josephson high-temperature superconducting (HTSC) submillimeter-wave spectrometer is designed, built, and experimentally investigated. The integrated detection structure of the spectrometer includes a YBCO Josephson junction on a bicrystalline boundary, a double-slot or log-periodic antenna, and a low-inductance resistive shunt. The selective detector response and the response at an intermediate frequency of 1.4 GHz are measured under the action of a signal in the frequency range 350–1250 GHz. Three methods of spectroscopy are investigated using this setup: 1) a method of Hilbert spectroscopy with processing of the detector response is implemented; 2) it is found that for a wide Josephson line at intermediate frequency (IF) the response has the same form as the detector response, making it possible to obtain a spectrum and the width of the generation line from IF response measurements; 3) for a narrow Josephson line the IF response corresponds to the regime of conversion with self-pumping. A new method is proposed for calculating the emission spectrum. The method consists of simple shift, summation, and subtraction operations. The advantages of the method are simplicity, high sensitivity, and high resolution.
An HTS Josephson spectrometer has been designed, fabricated and experimentally studied. The spectrometer circuit consists of a YBCO bicrystal Josephson junction integrated with a double-slot or log-periodic antenna, connected in parallel with a gold low-inductance shunt. The selective detector response and RF response at intermediate frequency f IF = 1.4 GHz were measured in the signal frequency range f s = 400-1250 GHz and the linewidth of Josephson oscillations (LJO) was determined by using three different methods. (1) The Hilbert spectroscopy approach was used in the processing of the selective detector response. (2) In case of f IF < LJO the detector and RF responses have similar shapes, allowing the spectrum and LJO to be extracted from the RF response and even processing by modified Hilbert spectroscopy. (3) The RF response at f IF > LJO corresponds to the frequency down-conversion in a self-pumped Josephson mixer mode. For the processing of the RF response in the high f IF limit we suggest a novel method that allows extraction of the signal spectrum by means of simple operations: shifting, summing and subtracting. The advantage of the RF response method is in its simplicity and higher sensitivity that allows it to be proposed for spectroscopy applications.