Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer

Jixi Lu, Zheng Qian, Jiancheng Fang, Wei Quan

Published Aug 1, 2015• 33 citations
Publisher

Abstract

This paper presents a method to reduce the vapor cell temperature error of the spin-exchange-relaxation-free (SERF) magnetometer. The fluctuation of cell temperature can induce variations of the optical rotation angle, resulting in a scale factor error of the SERF magnetometer. In order to suppress this error, we employ the variation of the probe beam absorption to offset the variation of the optical rotation angle. The theoretical discussion of our method indicates that the scale factor error introduced by the fluctuation of the cell temperature could be suppressed by setting the optical depth close to one. In our experiment, we adjust the probe frequency to obtain various optical depths and then measure the variation of scale factor with respect to the corresponding cell temperature changes. Our experimental results show a good agreement with our theoretical analysis. Under our experimental condition, the error has been reduced significantly compared with those when the probe wavelength is adjusted to maximize the probe signal. The cost of this method is the reduction of the scale factor of the magnetometer. However, according to our analysis, it only has minor effect on the sensitivity under proper operating parameters.

DOI
10.1063/1.4927720

Related papers

Suppression of the Bias Error Induced by Vapor Cell Temperature in a Spin-Exchange Relaxation-Free Gyroscope

Feng Liu, Lihong Duan, Wenfeng Fan +3 more

Bias stability is one of the most important characteristics of a spin-exchange relaxation-free gyroscope (SERFG). The previous research on the SERFG has demonstrated that atomic density fluctuation induced by the vapor cell temperature fluctuations in a SERFG limits its bias stability. In this paper, a steady-state response model of a SERFG dependent on the vapor cell temperature is established, and a method to reduce the vapor cell temperature error of the SERFG is developed. By adjusting the vapor cell temperature, the SERFG can be tuned to a working point where the output signal is insensitive to the cell temperature fluctuation, i.e., the insensitive point, so that the bias error induced by cell temperature fluctuations can be effectively suppressed. The proposed method is verified by experiments, and experimental results are in good agreement with the model. By using the proposed method, SERFG drift was reduced from 0.051 deg/h to 0.028 deg/h without adjusting the wavelength of the probe laser. This study presents a way to improve the SERFG performance, which is of reference value for quantitative error analysis and miniaturization in atomic gyroscopes.

IEEE Sensors Journal•Dec 27, 2021•24 citations

Suppression of thermal coupling noise in the SERF atomic co-magnetometer

Jiasen Ruan, Lihong Duan, Yang Fu +4 more

Heating the alkali metal vapor cell to obtain high atomic density is a prerequisite for realizing the high-precision measurement for spin-exchange relaxation-free (SERF) co-magnetometer. However, the thermo-magnetic and thermo-optical coupling noise caused by the temperature diffusion from the alkali vapor cell is one of the main factors restricting the co-magnetometer performance at present. Here the influence of heating on the SERF co-magnetometer was comprehensively studied, and the thermal error model of the system was established. A novel heat insulation structure for the co-magnetometer was designed, and the effectiveness was verified through monitoring of characteristic temperature points. Compared to the conventional oven support, the average maximum temperature difference within 12 h of the optical path and magnetic shielding systems (OPMSS) decreased by 52%, the bias instability of the co-magnetometer decreased by 24%, and the noise of the co-magnetometer at 1 Hz decreased by 33%. The experimental results demonstrate that this method reduces the temperature fluctuation of the OPMSS, effectively suppresses the thermal coupling noise, and thus improves the performance of the SERF co-magnetometer. Moreover, this method is also applicable to other quantum sensors based on alkali metal vapor cell.

Results in Physics•Sep 22, 2023•14 citations

Suppression of the vapor cell temperature error in a spin-exchange relaxation-free comagnetometer

Jiali Liu, Liwei Jiang, Chi Fang +2 more

Abstract The fluctuation of the vapor cell temperature leads to the variations of the density of the alkali metal atoms, which seriously damages the long-term stability of the spin-exchange relaxation-free (SERF) comagnetometer. To address this problem, we propose a novel method for suppressing the cell temperature error by manipulating the probe laser frequency. A temperature coefficient model of the SERF comagnetometer is established based on the steady-state response, which indicates that the comagnetometer can be tuned to a working point where the output signal is insensitive to the cell temperature fluctuation, and the working point is determined by the relaxation rate of the alkali metal atoms. The method is verified in a K−Rb− 21Ne comagnetometer, and the experimental results are consistent with the theory. The theory and method presented here lay a foundation for the practical applications of the SERF comagnetometer.

Chinese Physics B•Oct 9, 2024•4 citations

Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer

Yaxiang Wang, Tao Shi, Weiyong Zhou +5 more

In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm3.

Optics Express•Jun 7, 2022•14 citations

Probe beam influence on spin polarization in spin-exchange relaxation-free co-magnetometers

Yao Wei, Xing Li, Yueyang Zhai +4 more

Abstract Spin-exchange relaxation-free (SERF) co-magnetometers have promising applications in both inertial navigation and fundamental physics experiments. However, the fluctuation in the spin polarization caused by the probe beam has a non-negligible influence on the co-magnetometer signal. In this paper, a theoretical model containing three parameters of the probe beam is established by extending the coupled Bloch equation. Based on this model, the influence of probe power density on the transient and steady-state response of the SERF co-magnetometer is analyzed. According to the transient response model, a new measurement method for transverse optical pumping of the probe beam is proposed. Then, for the steady-state response model, a steady-state error suppression method is suggested by adjusting the degree of circular polarization of the probe beam. Eventually, the suppression method is used to refine the SERF co-magnetometer, achieving a suppression rate of 70.31% in transverse electron spin polarization fluctuations, thus improving the co-magnetometer to a stability of 0.0079∘ h−1. To our knowledge, this is better than what has been reported so far.

Journal of Physics D Applied Physics•Feb 20, 2023•5 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•62 citations
This paper presents a method to reduce the vapor cell temperature error of the spin-exchange-relaxation-free (SERF) magnetometer. The fluctuation of cell temperature can induce variations of the optical rotation angle, resulting in a scale factor error of the SERF magnetometer. In order to suppress this error, we employ the variation of the probe beam absorption to offset the variation of the optical rotation angle. The theoretical discussion of our method indicates that the scale factor error introduced by the fluctuation of the cell temperature could be suppressed by setting the optical depth close to one. In our experiment, we adjust the probe frequency to obtain various optical depths and then measure the variation of scale factor with respect to the corresponding cell temperature changes. Our experimental results show a good agreement with our theoretical analysis. Under our experimental condition, the error has been reduced significantly compared with those when the probe wavelength is adjusted to maximize the probe signal. The cost of this method is the reduction of the scale factor of the magnetometer. However, according to our analysis, it only has minor effect on the sensitivity under proper operating parameters.
Bias stability is one of the most important characteristics of a spin-exchange relaxation-free gyroscope (SERFG). The previous research on the SERFG has demonstrated that atomic density fluctuation induced by the vapor cell temperature fluctuations in a SERFG limits its bias stability. In this paper, a steady-state response model of a SERFG dependent on the vapor cell temperature is established, and a method to reduce the vapor cell temperature error of the SERFG is developed. By adjusting the vapor cell temperature, the SERFG can be tuned to a working point where the output signal is insensitive to the cell temperature fluctuation, i.e., the insensitive point, so that the bias error induced by cell temperature fluctuations can be effectively suppressed. The proposed method is verified by experiments, and experimental results are in good agreement with the model. By using the proposed method, SERFG drift was reduced from 0.051 deg/h to 0.028 deg/h without adjusting the wavelength of the probe laser. This study presents a way to improve the SERFG performance, which is of reference value for quantitative error analysis and miniaturization in atomic gyroscopes.
Heating the alkali metal vapor cell to obtain high atomic density is a prerequisite for realizing the high-precision measurement for spin-exchange relaxation-free (SERF) co-magnetometer. However, the thermo-magnetic and thermo-optical coupling noise caused by the temperature diffusion from the alkali vapor cell is one of the main factors restricting the co-magnetometer performance at present. Here the influence of heating on the SERF co-magnetometer was comprehensively studied, and the thermal error model of the system was established. A novel heat insulation structure for the co-magnetometer was designed, and the effectiveness was verified through monitoring of characteristic temperature points. Compared to the conventional oven support, the average maximum temperature difference within 12 h of the optical path and magnetic shielding systems (OPMSS) decreased by 52%, the bias instability of the co-magnetometer decreased by 24%, and the noise of the co-magnetometer at 1 Hz decreased by 33%. The experimental results demonstrate that this method reduces the temperature fluctuation of the OPMSS, effectively suppresses the thermal coupling noise, and thus improves the performance of the SERF co-magnetometer. Moreover, this method is also applicable to other quantum sensors based on alkali metal vapor cell.
Abstract The fluctuation of the vapor cell temperature leads to the variations of the density of the alkali metal atoms, which seriously damages the long-term stability of the spin-exchange relaxation-free (SERF) comagnetometer. To address this problem, we propose a novel method for suppressing the cell temperature error by manipulating the probe laser frequency. A temperature coefficient model of the SERF comagnetometer is established based on the steady-state response, which indicates that the comagnetometer can be tuned to a working point where the output signal is insensitive to the cell temperature fluctuation, and the working point is determined by the relaxation rate of the alkali metal atoms. The method is verified in a K−Rb− 21Ne comagnetometer, and the experimental results are consistent with the theory. The theory and method presented here lay a foundation for the practical applications of the SERF comagnetometer.
In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm3.
Abstract Spin-exchange relaxation-free (SERF) co-magnetometers have promising applications in both inertial navigation and fundamental physics experiments. However, the fluctuation in the spin polarization caused by the probe beam has a non-negligible influence on the co-magnetometer signal. In this paper, a theoretical model containing three parameters of the probe beam is established by extending the coupled Bloch equation. Based on this model, the influence of probe power density on the transient and steady-state response of the SERF co-magnetometer is analyzed. According to the transient response model, a new measurement method for transverse optical pumping of the probe beam is proposed. Then, for the steady-state response model, a steady-state error suppression method is suggested by adjusting the degree of circular polarization of the probe beam. Eventually, the suppression method is used to refine the SERF co-magnetometer, achieving a suppression rate of 70.31% in transverse electron spin polarization fluctuations, thus improving the co-magnetometer to a stability of 0.0079∘ h−1. To our knowledge, this is better than what has been reported so far.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.