Journal of Physics D Applied Physics

Probe beam influence on spin polarization in spin-exchange relaxation-free co-magnetometers

Yao Wei, Xing Li, Yueyang Zhai, Wenfeng Fan, Chi Fang, Feng Liu, Wei Quan

Published Mar 7, 2023• 5 citations
Publisher

Abstract

Spin-exchange relaxation-free (SERF) co-magnetometers have promising applications in both inertial navigation and fundamental physics experiments. However, the fluctuation in the spin polarization caused by the probe beam has a non-negligible influence on the co-magnetometer signal. In this paper, a theoretical model containing three parameters of the probe beam is established by extending the coupled Bloch equation. Based on this model, the influence of probe power density on the transient and steady-state response of the SERF co-magnetometer is analyzed. According to the transient response model, a new measurement method for transverse optical pumping of the probe beam is proposed. Then, for the steady-state response model, a steady-state error suppression method is suggested by adjusting the degree of circular polarization of the probe beam. Eventually, the suppression method is used to refine the SERF co-magnetometer, achieving a suppression rate of 70.31% in transverse electron spin polarization fluctuations, thus improving the co-magnetometer to a stability of 0.0079∘ h−1. To our knowledge, this is better than what has been reported so far.

DOI
10.1088/1361-6463/acbd60

Related papers

Transverse light-shift in a spin-exchange relaxation-free co-magnetometer: measurement, decoupling, and suppression

Sixun Liu, Ruigang Wang, Linlin Yuan +6 more

The transverse light-shift can induce non-negligible polarization error in the output signal of spin-exchange relaxation-free (SERF) co-magnetometer. In this paper, a novel method for rapid measurement of transverse light-shift based on the error of steady-state response of co-magnetometer is proposed firstly, then the sources of transverse light-shift in a compact SERF co-magnetometer is modeled and analyzed from three aspects: the non-ideal linear polarization of probe laser, the circular dichroism of the atomic spin ensembles, and the stress-induced birefringence effect of the cell wall. Furthermore, the decoupling and suppression methods of transverse light-shift based on a degree of circular polarization (DOCP) regulation scheme is presented, to realize the decoupling measurement of the transverse light-shift introduced by the whole co-magnetometer cell, and cancel it out with the non-ideal linear polarization of the probe laser. Eventually, the DOCP regulation scheme suggested in this paper achieves more than a 67% suppression ratio in transverse light-shift, and the short- and long-term performance of SERF co-magnetometer are improved due to the reduction of the coupling effect between the probe laser power and transverse field. Moreover, the measurement, decoupling and suppression methods provided in this paper also have the potential to be applied to other atomic sensors, such as the SERF magnetometers and nuclear spin co-magnetometers.

Optics Express•Apr 20, 2022•34 citations

Comprehensive analysis of the impact of optical magnetic misalignment on the performance of the SERF co-magnetometer

Ze Yu Cai, Lihong Duan, Shimiao Fan +2 more

The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.

Optics Express•Apr 24, 2025•4 citations

Nonlinear Effect Analysis and Sensitivity Improvement in Spin Exchange Relaxation Free Atomic Magnetometers

Bozheng Xing, Ning Ma, Haoran Lv +1 more

In this study, the influence of the nonlinear magneto–optical rotation effect on a spin‐exchange relaxation‐free (SERF) atomic magnetometer is analyzed. The nonlinear effect is described by saturation parameters obtained from the density matrix model considering the Rabi oscillation of the probe light. For better sensitivity, the nonlinear effect is suppressed, and larger output signals are achieved. Based on the nonlinear effect analysis, the relationship between the probe sensitivity and light power density is obtained, and the optimal probe light power density is measured with best probe sensitivity. The best probe sensitivity improves by ≈6 times at the optimal probe light power density compared with that in the conventional linear optical rotation detection. The proposed method can be applied to SERF magnetometers, co‐magnetometers, and atomic spin gyroscopes.

Advanced Quantum Technologies•Jul 25, 2024•8 citations

Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer

Jixi Lu, Zheng Qian, Jiancheng Fang +1 more

This paper presents a method to reduce the vapor cell temperature error of the spin-exchange-relaxation-free (SERF) magnetometer. The fluctuation of cell temperature can induce variations of the optical rotation angle, resulting in a scale factor error of the SERF magnetometer. In order to suppress this error, we employ the variation of the probe beam absorption to offset the variation of the optical rotation angle. The theoretical discussion of our method indicates that the scale factor error introduced by the fluctuation of the cell temperature could be suppressed by setting the optical depth close to one. In our experiment, we adjust the probe frequency to obtain various optical depths and then measure the variation of scale factor with respect to the corresponding cell temperature changes. Our experimental results show a good agreement with our theoretical analysis. Under our experimental condition, the error has been reduced significantly compared with those when the probe wavelength is adjusted to maximize the probe signal. The cost of this method is the reduction of the scale factor of the magnetometer. However, according to our analysis, it only has minor effect on the sensitivity under proper operating parameters.

Review of Scientific Instruments•Aug 1, 2015•34 citations

Measurement of Equilibrium Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometers via the Steady-State Response to the Triaxial Magnetic Field

Faming Wang, Xiujie Fang, Bozheng Xing +5 more

This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•8 citations

Determination of Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometer Using Transient Response

Junpeng Zhao, Ming Ding, Jixi Lu +5 more

A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.

IEEE Transactions on Instrumentation and Measurement•Apr 27, 2019•70 citations
Spin-exchange relaxation-free (SERF) co-magnetometers have promising applications in both inertial navigation and fundamental physics experiments. However, the fluctuation in the spin polarization caused by the probe beam has a non-negligible influence on the co-magnetometer signal. In this paper, a theoretical model containing three parameters of the probe beam is established by extending the coupled Bloch equation. Based on this model, the influence of probe power density on the transient and steady-state response of the SERF co-magnetometer is analyzed. According to the transient response model, a new measurement method for transverse optical pumping of the probe beam is proposed. Then, for the steady-state response model, a steady-state error suppression method is suggested by adjusting the degree of circular polarization of the probe beam. Eventually, the suppression method is used to refine the SERF co-magnetometer, achieving a suppression rate of 70.31% in transverse electron spin polarization fluctuations, thus improving the co-magnetometer to a stability of 0.0079∘ h−1. To our knowledge, this is better than what has been reported so far.
The transverse light-shift can induce non-negligible polarization error in the output signal of spin-exchange relaxation-free (SERF) co-magnetometer. In this paper, a novel method for rapid measurement of transverse light-shift based on the error of steady-state response of co-magnetometer is proposed firstly, then the sources of transverse light-shift in a compact SERF co-magnetometer is modeled and analyzed from three aspects: the non-ideal linear polarization of probe laser, the circular dichroism of the atomic spin ensembles, and the stress-induced birefringence effect of the cell wall. Furthermore, the decoupling and suppression methods of transverse light-shift based on a degree of circular polarization (DOCP) regulation scheme is presented, to realize the decoupling measurement of the transverse light-shift introduced by the whole co-magnetometer cell, and cancel it out with the non-ideal linear polarization of the probe laser. Eventually, the DOCP regulation scheme suggested in this paper achieves more than a 67% suppression ratio in transverse light-shift, and the short- and long-term performance of SERF co-magnetometer are improved due to the reduction of the coupling effect between the probe laser power and transverse field. Moreover, the measurement, decoupling and suppression methods provided in this paper also have the potential to be applied to other atomic sensors, such as the SERF magnetometers and nuclear spin co-magnetometers.
The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.
In this study, the influence of the nonlinear magneto–optical rotation effect on a spin‐exchange relaxation‐free (SERF) atomic magnetometer is analyzed. The nonlinear effect is described by saturation parameters obtained from the density matrix model considering the Rabi oscillation of the probe light. For better sensitivity, the nonlinear effect is suppressed, and larger output signals are achieved. Based on the nonlinear effect analysis, the relationship between the probe sensitivity and light power density is obtained, and the optimal probe light power density is measured with best probe sensitivity. The best probe sensitivity improves by ≈6 times at the optimal probe light power density compared with that in the conventional linear optical rotation detection. The proposed method can be applied to SERF magnetometers, co‐magnetometers, and atomic spin gyroscopes.
This paper presents a method to reduce the vapor cell temperature error of the spin-exchange-relaxation-free (SERF) magnetometer. The fluctuation of cell temperature can induce variations of the optical rotation angle, resulting in a scale factor error of the SERF magnetometer. In order to suppress this error, we employ the variation of the probe beam absorption to offset the variation of the optical rotation angle. The theoretical discussion of our method indicates that the scale factor error introduced by the fluctuation of the cell temperature could be suppressed by setting the optical depth close to one. In our experiment, we adjust the probe frequency to obtain various optical depths and then measure the variation of scale factor with respect to the corresponding cell temperature changes. Our experimental results show a good agreement with our theoretical analysis. Under our experimental condition, the error has been reduced significantly compared with those when the probe wavelength is adjusted to maximize the probe signal. The cost of this method is the reduction of the scale factor of the magnetometer. However, according to our analysis, it only has minor effect on the sensitivity under proper operating parameters.
This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.
A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.