Optics Express

Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer

Yaxiang Wang, Tao Shi, Weiyong Zhou, Junjian Tang, Binquan Zhou, Ge Jin, Bangcheng Han, Sheng Zou

Published Jun 7, 2022• 14 citations
Publisher

Abstract

In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm3.

DOI
10.1364/oe.458827

Related papers

Optimized gas pressure of an Rb vapor cell in a single-beam SERF magnetometer

Yaxiang Wang, Ge Jin, Junjian Tang +4 more

We present a theoretical and experimental study of a single-beam spin-exchange relaxation-free magnetometer in 87Rb vapor cells under different nitrogen gas pressures. The spin relaxation rate is a key component to limit the magnetic sensitivity, and the zero-field resonance method was used to measure the spin relaxation rates of different alkali metal cells. Simultaneously, in a single-beam spin-exchange-relaxation-free (SERF) magnetometer, we demonstrated that the fundamental magnetic field sensitivity was also limited by the pumping light intensity. Based on our theoretical analysis and experimental results, we determined the optimal pumping light intensity and optimal gas pressure. We experimentally demonstrated that the magnetic field sensitivity was 8.89 fT / Hz in the single-beam configuration, with an active measurement volume of 3 × 3 × 3~mm3.

Optics Express•Dec 15, 2021•42 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•62 citations

The polarization and the fundamental sensitivity of 39K (133Cs)-85Rb-4He hybrid optical pumping spin exchange relaxation free atomic magnetometers

Jianhua Liu, Dong-Yang Jing, Liang‐Liang Wang +4 more

Abstract The hybrid optical pumping spin exchange relaxation free (SERF) atomic magnetometers can realize ultrahigh sensitivity measurement of magnetic field and inertia. We have studied the 85 Rb polarization of two types of hybrid optical pumping SERF magnetometers based on 39 K- 85 Rb- 4 He and 133 Cs- 85 Rb- 4 He respectively. Then we found that 85 Rb polarization varies with the number density of buffer gas 4 He and quench gas N 2 , pumping rate of pump beam and cell temperature respectively, which will provide an experimental guide for the design of the magnetometer. We obtain a general formula on the fundamental sensitivity of the hybrid optical pumping SERF magnetometer due to shot-noise. The formula describes that the fundamental sensitivity of the magnetometer varies with the number density of buffer gas and quench gas, the pumping rate of pump beam, external magnetic field, cell effective radius, measurement volume, cell temperature and measurement time. We obtain a highest fundamental sensitivity of 1.5073 aT / Hz 1/2 (1 aT = 10 −18 T ) with 39 K- 85 Rb- 4 He magnetometer between above two types of magnetometers when 85 Rb polarization is 0.1116. We estimate the fundamental sensitivity limit of the hybrid optical pumping SERF magnetometer to be superior to 1.8359 × 10 −2 aT / Hz 1/2 , which is higher than the shot-noise-limited sensitivity of 1 aT / Hz 1/2 of K SERF atomic magnetometer.

arXiv:1702.07755•Scientific Reports•Jul 24, 2017•17 citations

Pulsed operation of a miniature scalar optically pumped magnetometer

Vladislav P. Gerginov, Sean Krzyzewski, Svenja A. Knappe

A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.

Journal of the Optical Society of America B•Jun 15, 2017•57 citations

Miniaturized Dual-Beam SERF Magnetometer Using Natural Abundance Rubidium

Jianwei Sheng, Ziao Liu, Xiaoyu Li +3 more

Due to high sensitivity and compactness, spin-exchange relaxation-free (SERF) atomic magnetometers have found widespread applications. These devices rely on alkali atoms to sense magnetic fields, with87Rb being the commonly used isotope. However,87Rb must be extracted from natural abundance rubidium (natRb) through isotopic separation, making it expensive. Replacing87Rb with natRb reduces the cost to approximately just 1%. Nevertheless, it is generally believed that the isotopic mixture of87Rb and85Rb in natRb affects the coherence of the atomic ensemble. Using a dual-beam SERF magnetometer, we systematically compared 3 mm inner-size cubic vapor cells filled with natRb and87Rb. By optimizing the buffer gas pressure and optical parameters, we demonstrate that the natRb magnetometer can achieve performance comparable to that of the87Rb magnetometer. Experimental results show that both cells achieved a sensitivity of 4 1T/Hz1/2. These findings demonstrate that natRb can effectively replace87Rb in miniaturized dual-beam SERF magnetometers, enabling low-cost, high-sensitivity magnetic field measurements.

IEEE International Conference on Electronic Measurement & Instruments•Aug 22, 2025•0 citations

Probe noise characteristics of the spin-exchange relaxation-free (SERF) magnetometer

Bozheng Xing, Chang Sun, Ziao Liu +4 more

In the spin-exchange relaxation-free (SERF) magnetometer, the probe noise is a consequential factor affecting the gradiometric measurement sensitivities. In this paper, we proposed a new characteristics model of the probe noise based on noise separation. Different from noise analysis on single noise source, we considered most of the noise sources influencing the probe system and realized noise sources level measurement experimentally. The results demonstrate that the major noise type changes with the signal frequency. Below 10 Hz, the probe noise mainly comes from the sources independent of light intensity such as the vibration, which accounts for more than 50%; while at 30 Hz, the photon shot noise and the magnetic noise are the main origins, with proportion about 43% and 32%, respectively. Moreover, the results indicate that the optimal probe light intensity with highest sensitivity appears when the response of the magnetic noise is equal to the sum of the electronic noise and half of the shot noise. The optimal intensity gets larger with higher signal frequency. The noise characteristics model could be applied in modulating or differential optical systems and helps sensitivity improvement in SERF magnetometer.

Optics Express•Jan 25, 2021•30 citations
In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm3.
We present a theoretical and experimental study of a single-beam spin-exchange relaxation-free magnetometer in 87Rb vapor cells under different nitrogen gas pressures. The spin relaxation rate is a key component to limit the magnetic sensitivity, and the zero-field resonance method was used to measure the spin relaxation rates of different alkali metal cells. Simultaneously, in a single-beam spin-exchange-relaxation-free (SERF) magnetometer, we demonstrated that the fundamental magnetic field sensitivity was also limited by the pumping light intensity. Based on our theoretical analysis and experimental results, we determined the optimal pumping light intensity and optimal gas pressure. We experimentally demonstrated that the magnetic field sensitivity was 8.89 fT / Hz in the single-beam configuration, with an active measurement volume of 3 × 3 × 3~mm3.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
Abstract The hybrid optical pumping spin exchange relaxation free (SERF) atomic magnetometers can realize ultrahigh sensitivity measurement of magnetic field and inertia. We have studied the 85 Rb polarization of two types of hybrid optical pumping SERF magnetometers based on 39 K- 85 Rb- 4 He and 133 Cs- 85 Rb- 4 He respectively. Then we found that 85 Rb polarization varies with the number density of buffer gas 4 He and quench gas N 2 , pumping rate of pump beam and cell temperature respectively, which will provide an experimental guide for the design of the magnetometer. We obtain a general formula on the fundamental sensitivity of the hybrid optical pumping SERF magnetometer due to shot-noise. The formula describes that the fundamental sensitivity of the magnetometer varies with the number density of buffer gas and quench gas, the pumping rate of pump beam, external magnetic field, cell effective radius, measurement volume, cell temperature and measurement time. We obtain a highest fundamental sensitivity of 1.5073 aT / Hz 1/2 (1 aT = 10 −18 T ) with 39 K- 85 Rb- 4 He magnetometer between above two types of magnetometers when 85 Rb polarization is 0.1116. We estimate the fundamental sensitivity limit of the hybrid optical pumping SERF magnetometer to be superior to 1.8359 × 10 −2 aT / Hz 1/2 , which is higher than the shot-noise-limited sensitivity of 1 aT / Hz 1/2 of K SERF atomic magnetometer.
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.
Due to high sensitivity and compactness, spin-exchange relaxation-free (SERF) atomic magnetometers have found widespread applications. These devices rely on alkali atoms to sense magnetic fields, with87Rb being the commonly used isotope. However,87Rb must be extracted from natural abundance rubidium (natRb) through isotopic separation, making it expensive. Replacing87Rb with natRb reduces the cost to approximately just 1%. Nevertheless, it is generally believed that the isotopic mixture of87Rb and85Rb in natRb affects the coherence of the atomic ensemble. Using a dual-beam SERF magnetometer, we systematically compared 3 mm inner-size cubic vapor cells filled with natRb and87Rb. By optimizing the buffer gas pressure and optical parameters, we demonstrate that the natRb magnetometer can achieve performance comparable to that of the87Rb magnetometer. Experimental results show that both cells achieved a sensitivity of 4 1T/Hz1/2. These findings demonstrate that natRb can effectively replace87Rb in miniaturized dual-beam SERF magnetometers, enabling low-cost, high-sensitivity magnetic field measurements.
In the spin-exchange relaxation-free (SERF) magnetometer, the probe noise is a consequential factor affecting the gradiometric measurement sensitivities. In this paper, we proposed a new characteristics model of the probe noise based on noise separation. Different from noise analysis on single noise source, we considered most of the noise sources influencing the probe system and realized noise sources level measurement experimentally. The results demonstrate that the major noise type changes with the signal frequency. Below 10 Hz, the probe noise mainly comes from the sources independent of light intensity such as the vibration, which accounts for more than 50%; while at 30 Hz, the photon shot noise and the magnetic noise are the main origins, with proportion about 43% and 32%, respectively. Moreover, the results indicate that the optimal probe light intensity with highest sensitivity appears when the response of the magnetic noise is equal to the sum of the electronic noise and half of the shot noise. The optimal intensity gets larger with higher signal frequency. The noise characteristics model could be applied in modulating or differential optical systems and helps sensitivity improvement in SERF magnetometer.