Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Results in Physics

Suppression of thermal coupling noise in the SERF atomic co-magnetometer

Jiasen Ruan, Lihong Duan, Yang Fu, Lv Yang, Wenfeng Fan, Xinxiu Zhou, Wei Quan

Published Sep 22, 2023• 14 citations
Publisher

Abstract

Heating the alkali metal vapor cell to obtain high atomic density is a prerequisite for realizing the high-precision measurement for spin-exchange relaxation-free (SERF) co-magnetometer. However, the thermo-magnetic and thermo-optical coupling noise caused by the temperature diffusion from the alkali vapor cell is one of the main factors restricting the co-magnetometer performance at present. Here the influence of heating on the SERF co-magnetometer was comprehensively studied, and the thermal error model of the system was established. A novel heat insulation structure for the co-magnetometer was designed, and the effectiveness was verified through monitoring of characteristic temperature points. Compared to the conventional oven support, the average maximum temperature difference within 12 h of the optical path and magnetic shielding systems (OPMSS) decreased by 52%, the bias instability of the co-magnetometer decreased by 24%, and the noise of the co-magnetometer at 1 Hz decreased by 33%. The experimental results demonstrate that this method reduces the temperature fluctuation of the OPMSS, effectively suppresses the thermal coupling noise, and thus improves the performance of the SERF co-magnetometer. Moreover, this method is also applicable to other quantum sensors based on alkali metal vapor cell.

DOI
10.1016/j.rinp.2023.107007

Related papers

Transient Heat Transfer Modeling of SERF Co-Magnetometer Atomic Ensemble Based on the Thermoelectric Analogy Method

Jiaqi Wu, Feng Liu, Lihong Duan +3 more

Bias instability is one of the most critical factors in the performance of spin-exchange relaxation-free (SERF) co-magnetometers. Previous studies on SERF co-magnetometers have shown that changes in the atomic ensemble temperature can lead to variations in the alkali metal atom density, which in turn affect the optical rotation angle and light shift, ultimately influencing the system’s stability. Building on this understanding, this paper introduces the thermoelectric analogy method for the first time in the transient heat transfer analysis of SERF co-magnetometer atomic ensembles. Using this method, the primary factors affecting the atomic ensemble temperature in a SERF co-magnetometer were analyzed, and transient heat transfer models were established for the following processes: the interaction between the non-magnetic electric heating system and the atomic ensemble temperature, laser heating of the atomic ensemble by the optical system, and the effect of environmental temperature changes on the non-magnetic electric heating system. These models were experimentally validated through active temperature variation experiments. The experimental results show that the proposed transient heat transfer models accurately describe the related heat transfer processes of the atomic ensemble, with model fitting accuracy exceeding 98%. This lays a solid foundation for the high-precision closed-loop control of the atomic ensemble temperature in SERF co-magnetometers and provides valuable insights for the structural design and engineering applications of SERF co-magnetometers.

Photonics•Feb 28, 2025•2 citations

The Space Density Distribution of Alkali Metal Atoms in a SERF Atomic Magnetometer

Qiang Guo, Xuewen Li, Ning Zhang +4 more

The number density of alkali atoms in vaper cell is an important parameter for atomic magnetometer. The vapor cell is usually heated to a high temperature for the number density exceed to 1018m−3to achieve the spin-exchange-relaxation-free (SERF) process. The optical rotation of multichannel atomic magnetometers is affected by the number density distribution. We present an effective method for monitoring and analyzing the spatial distribution homogeneity of the atomic number density in the alkali metal cell within the SERF magnetometer. The numerical results from researching the model of electric heating films and ovens show that the temperature gradient increases with an increase in the cell temperature. This causes an nonuniform number density distribution based on the saturated vapor pressure curve. We present a laser absorption spectroscopy method by using the high-resolution beam profiling camera to record the power of the beam before and after the cell. An optimized optical system of the atomic magnetometer has been established by measuring the the number density variation in the spatial distribution in mm scale. The number density variation coefficient, which is introduced to evaluate the distribution homogeneity, increases from 0.0257 to 0.0333 when the temperature of the oven wall rises from 140°C to 190 °C, showing the same trend as the simulation results. The optical rotation distribution is calculated according to the magnetometer output signal formula. This study is of great interest for optimizing the oven structure and improving the stability of atomic spin polarization and sensitivity of the multichannel magnetometer.

IEEE Sensors Journal•Jan 27, 2022•13 citations

Decoupling and suppression of opto-thermal drifts in SERF atomic co-magnetometers via precise null-point characterization

Xiaoping Li, Wenfeng Fan, Shimiao Fan +2 more

The long-term bias stability of spin-exchange relaxation-free atomic co-magnetometers is significantly constrained by coupled opto-thermal fluctuations. Traditionally, random systemic offsets at the magnetic compensation point lead to inconsistent opto-thermal coupling, compromising the reproducibility of sensor performance. In this work, we propose a method to simultaneously decouple and suppress these primary drifts by precisely characterizing the physical null-point of the atomic ensemble. A combined compensation scheme, joining residual rotation angle alignment and transverse magnetic field adjustment, is implemented to isolate the sensor output from fluctuations in probe laser intensity and vapor cell temperature. Experimental results demonstrate that the sensitivities to temperature drifts and probe power fluctuations are suppressed simultaneously at the identified null-point by factors of 72 and 880, respectively. This approach establishes a stable zero point, which is expected to significantly enhance sensor reproducibility and stability without sacrificing fundamental sensing performance.

Applied Physics Letters•Apr 20, 2026•2 citations

Suppression of the vapor cell temperature error in a spin-exchange relaxation-free comagnetometer

Jiali Liu, Liwei Jiang, Chi Fang +2 more

Abstract The fluctuation of the vapor cell temperature leads to the variations of the density of the alkali metal atoms, which seriously damages the long-term stability of the spin-exchange relaxation-free (SERF) comagnetometer. To address this problem, we propose a novel method for suppressing the cell temperature error by manipulating the probe laser frequency. A temperature coefficient model of the SERF comagnetometer is established based on the steady-state response, which indicates that the comagnetometer can be tuned to a working point where the output signal is insensitive to the cell temperature fluctuation, and the working point is determined by the relaxation rate of the alkali metal atoms. The method is verified in a K−Rb− 21Ne comagnetometer, and the experimental results are consistent with the theory. The theory and method presented here lay a foundation for the practical applications of the SERF comagnetometer.

Chinese Physics B•Oct 9, 2024•4 citations

Comprehensive analysis of the impact of optical magnetic misalignment on the performance of the SERF co-magnetometer

Ze Yu Cai, Lihong Duan, Shimiao Fan +2 more

The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.

Optics Express•Apr 10, 2025•4 citations

Compact current-heating apparatus for SERF atomic magnetometer

Tang Xingbin, Dong Haifeng

The spin-exchange relaxation-free (SERF) atomic magnetometer is one of the ultra-sensitive magnetometers, which must be operated in a low magnetic field and heated more than 100°C. One of the main engineering difficulties in fabricating a SERF atomic magnetometer is to develop a heater that introduces no additional magnetic noise into the measurement system. In this paper, a novel compact current-heating scheme and apparatus for the SERF atomic magnetometer are proposed. The thermal and magnetic simulations of this apparatus are carried out and the results of the simulations demonstrate the feasibility of this heating apparatus: the vapor cell can be heated to a temperature of 103°C and magnetic field introduced in the magnetometer can be limited in 10nT.

IEEE International Conference on Electronic Measurement & Instruments•Aug 1, 2011•0 citations
Heating the alkali metal vapor cell to obtain high atomic density is a prerequisite for realizing the high-precision measurement for spin-exchange relaxation-free (SERF) co-magnetometer. However, the thermo-magnetic and thermo-optical coupling noise caused by the temperature diffusion from the alkali vapor cell is one of the main factors restricting the co-magnetometer performance at present. Here the influence of heating on the SERF co-magnetometer was comprehensively studied, and the thermal error model of the system was established. A novel heat insulation structure for the co-magnetometer was designed, and the effectiveness was verified through monitoring of characteristic temperature points. Compared to the conventional oven support, the average maximum temperature difference within 12 h of the optical path and magnetic shielding systems (OPMSS) decreased by 52%, the bias instability of the co-magnetometer decreased by 24%, and the noise of the co-magnetometer at 1 Hz decreased by 33%. The experimental results demonstrate that this method reduces the temperature fluctuation of the OPMSS, effectively suppresses the thermal coupling noise, and thus improves the performance of the SERF co-magnetometer. Moreover, this method is also applicable to other quantum sensors based on alkali metal vapor cell.
Bias instability is one of the most critical factors in the performance of spin-exchange relaxation-free (SERF) co-magnetometers. Previous studies on SERF co-magnetometers have shown that changes in the atomic ensemble temperature can lead to variations in the alkali metal atom density, which in turn affect the optical rotation angle and light shift, ultimately influencing the system’s stability. Building on this understanding, this paper introduces the thermoelectric analogy method for the first time in the transient heat transfer analysis of SERF co-magnetometer atomic ensembles. Using this method, the primary factors affecting the atomic ensemble temperature in a SERF co-magnetometer were analyzed, and transient heat transfer models were established for the following processes: the interaction between the non-magnetic electric heating system and the atomic ensemble temperature, laser heating of the atomic ensemble by the optical system, and the effect of environmental temperature changes on the non-magnetic electric heating system. These models were experimentally validated through active temperature variation experiments. The experimental results show that the proposed transient heat transfer models accurately describe the related heat transfer processes of the atomic ensemble, with model fitting accuracy exceeding 98%. This lays a solid foundation for the high-precision closed-loop control of the atomic ensemble temperature in SERF co-magnetometers and provides valuable insights for the structural design and engineering applications of SERF co-magnetometers.
The number density of alkali atoms in vaper cell is an important parameter for atomic magnetometer. The vapor cell is usually heated to a high temperature for the number density exceed to 1018m−3to achieve the spin-exchange-relaxation-free (SERF) process. The optical rotation of multichannel atomic magnetometers is affected by the number density distribution. We present an effective method for monitoring and analyzing the spatial distribution homogeneity of the atomic number density in the alkali metal cell within the SERF magnetometer. The numerical results from researching the model of electric heating films and ovens show that the temperature gradient increases with an increase in the cell temperature. This causes an nonuniform number density distribution based on the saturated vapor pressure curve. We present a laser absorption spectroscopy method by using the high-resolution beam profiling camera to record the power of the beam before and after the cell. An optimized optical system of the atomic magnetometer has been established by measuring the the number density variation in the spatial distribution in mm scale. The number density variation coefficient, which is introduced to evaluate the distribution homogeneity, increases from 0.0257 to 0.0333 when the temperature of the oven wall rises from 140°C to 190 °C, showing the same trend as the simulation results. The optical rotation distribution is calculated according to the magnetometer output signal formula. This study is of great interest for optimizing the oven structure and improving the stability of atomic spin polarization and sensitivity of the multichannel magnetometer.
The long-term bias stability of spin-exchange relaxation-free atomic co-magnetometers is significantly constrained by coupled opto-thermal fluctuations. Traditionally, random systemic offsets at the magnetic compensation point lead to inconsistent opto-thermal coupling, compromising the reproducibility of sensor performance. In this work, we propose a method to simultaneously decouple and suppress these primary drifts by precisely characterizing the physical null-point of the atomic ensemble. A combined compensation scheme, joining residual rotation angle alignment and transverse magnetic field adjustment, is implemented to isolate the sensor output from fluctuations in probe laser intensity and vapor cell temperature. Experimental results demonstrate that the sensitivities to temperature drifts and probe power fluctuations are suppressed simultaneously at the identified null-point by factors of 72 and 880, respectively. This approach establishes a stable zero point, which is expected to significantly enhance sensor reproducibility and stability without sacrificing fundamental sensing performance.
Abstract The fluctuation of the vapor cell temperature leads to the variations of the density of the alkali metal atoms, which seriously damages the long-term stability of the spin-exchange relaxation-free (SERF) comagnetometer. To address this problem, we propose a novel method for suppressing the cell temperature error by manipulating the probe laser frequency. A temperature coefficient model of the SERF comagnetometer is established based on the steady-state response, which indicates that the comagnetometer can be tuned to a working point where the output signal is insensitive to the cell temperature fluctuation, and the working point is determined by the relaxation rate of the alkali metal atoms. The method is verified in a K−Rb− 21Ne comagnetometer, and the experimental results are consistent with the theory. The theory and method presented here lay a foundation for the practical applications of the SERF comagnetometer.
The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.
The spin-exchange relaxation-free (SERF) atomic magnetometer is one of the ultra-sensitive magnetometers, which must be operated in a low magnetic field and heated more than 100°C. One of the main engineering difficulties in fabricating a SERF atomic magnetometer is to develop a heater that introduces no additional magnetic noise into the measurement system. In this paper, a novel compact current-heating scheme and apparatus for the SERF atomic magnetometer are proposed. The thermal and magnetic simulations of this apparatus are carried out and the results of the simulations demonstrate the feasibility of this heating apparatus: the vapor cell can be heated to a temperature of 103°C and magnetic field introduced in the magnetometer can be limited in 10nT.