The number density of alkali atoms in vaper cell is an important parameter for atomic magnetometer. The vapor cell is usually heated to a high temperature for the number density exceed to 1018m−3to achieve the spin-exchange-relaxation-free (SERF) process. The optical rotation of multichannel atomic magnetometers is affected by the number density distribution. We present an effective method for monitoring and analyzing the spatial distribution homogeneity of the atomic number density in the alkali metal cell within the SERF magnetometer. The numerical results from researching the model of electric heating films and ovens show that the temperature gradient increases with an increase in the cell temperature. This causes an nonuniform number density distribution based on the saturated vapor pressure curve. We present a laser absorption spectroscopy method by using the high-resolution beam profiling camera to record the power of the beam before and after the cell. An optimized optical system of the atomic magnetometer has been established by measuring the the number density variation in the spatial distribution in mm scale. The number density variation coefficient, which is introduced to evaluate the distribution homogeneity, increases from 0.0257 to 0.0333 when the temperature of the oven wall rises from 140°C to 190 °C, showing the same trend as the simulation results. The optical rotation distribution is calculated according to the magnetometer output signal formula. This study is of great interest for optimizing the oven structure and improving the stability of atomic spin polarization and sensitivity of the multichannel magnetometer.
The number density of alkali atoms in vaper cell is an important parameter for atomic magnetometer. The vapor cell is usually heated to a high temperature for the number density exceed to 1018m−3to achieve the spin-exchange-relaxation-free (SERF) process. The optical rotation of multichannel atomic magnetometers is affected by the number density distribution. We present an effective method for monitoring and analyzing the spatial distribution homogeneity of the atomic number density in the alkali metal cell within the SERF magnetometer. The numerical results from researching the model of electric heating films and ovens show that the temperature gradient increases with an increase in the cell temperature. This causes an nonuniform number density distribution based on the saturated vapor pressure curve. We present a laser absorption spectroscopy method by using the high-resolution beam profiling camera to record the power of the beam before and after the cell. An optimized optical system of the atomic magnetometer has been established by measuring the the number density variation in the spatial distribution in mm scale. The number density variation coefficient, which is introduced to evaluate the distribution homogeneity, increases from 0.0257 to 0.0333 when the temperature of the oven wall rises from 140°C to 190 °C, showing the same trend as the simulation results. The optical rotation distribution is calculated according to the magnetometer output signal formula. This study is of great interest for optimizing the oven structure and improving the stability of atomic spin polarization and sensitivity of the multichannel magnetometer.
This study presents a novel method for measuring the number density of K in K-Rb hybrid vapor cells using circularly polarized pump light on polarized alkali metal atoms. This proposed method eliminates the need for additional devices such as absorption spectroscopy, Faraday rotation, or resistance temperature detector technology. The modeling process involved considering wall loss, scattering loss, atomic absorption loss, and atomic saturation absorption, with experiments designed to identify the relevant parameters. The proposed method is real-time, highly stable, and a quantum nondemolition measurement that does not disrupt the spin-exchange relaxation-free (SERF) regime. Experimental results demonstrate the effectiveness of the proposed method, as the longitudinal electron spin polarization long-term stability increased by 204% and the transversal electron spin polarization long-term stability increased by 44.8%, as evaluated by the Allan variance.
High sensitivity measurements of inertia and magnetic field could be achieved by utilizing a category of devices, which manipulate the atomic spins in the spin-exchange-relaxation-free regime. The alkali cell which contains the alkali metal vapor is used to sense magnetic field and inertia. The atomic number density of alkali vapor and the polarization of alkali metal vapor are two of the most important parameters of the cell. They play an important role in the research on atomic spins in the spin-exchange-relaxation-free regime. Besides, optical polarization plays an important role in quantum computing and atomic physics. We propose a measurement of alkali vapor polarization and alkali number density by detecting the optical rotation in one system. This method simplifies existing experimental equipment and processes. A constant bias magnetic field is applied and the Faraday rotation angle is detected by a bunch of the probe beam to deduce alkali-metal density. Then the magnetic field is closed and a bunch of the pump laser is utilized to polarize alkali-metal. Again, the probe beam is utilized to obtain the polarization of alkali metal. The alkali density obtained at first is used to deduce the polarization. This paper applies a numerical method to analyze the Faraday rotation and the polarization rotation. According to the numerical method, the optimal wavelength for the experiment is given. Finally, the fluctuation of magnetic field and wavelength on signal analysis are analyzed.
The atomic density of an alkali vapor cell is a critical factor in determining the performance of atomic magnetometers. This paper presents a novel method to detect the density of an alkali atomic ensemble under arbitrary polarization states. By establishing a comprehensive model that correlates the absorption spectrum with the incident light’s polarization, our approach enables real-time and flexible measurements across varying temperatures and polarization angles. Experimental validations are conducted by systematically rotating a quarter-wave plate and controlling the vapor cell temperature, thereby collecting transmission spectra at multiple polarizations. The results demonstrate that the proposed method simplifies density measurements while preserving high accuracy, laying a solid foundation for further research on Spin-Exchange Relaxation-Free (SERF) atomic magnetometers. This technique serves as a versatile and effective tool for in-situ monitoring of alkali metal vapor density in various sensor applications.
Heating the alkali metal vapor cell to obtain high atomic density is a prerequisite for realizing the high-precision measurement for spin-exchange relaxation-free (SERF) co-magnetometer. However, the thermo-magnetic and thermo-optical coupling noise caused by the temperature diffusion from the alkali vapor cell is one of the main factors restricting the co-magnetometer performance at present. Here the influence of heating on the SERF co-magnetometer was comprehensively studied, and the thermal error model of the system was established. A novel heat insulation structure for the co-magnetometer was designed, and the effectiveness was verified through monitoring of characteristic temperature points. Compared to the conventional oven support, the average maximum temperature difference within 12 h of the optical path and magnetic shielding systems (OPMSS) decreased by 52%, the bias instability of the co-magnetometer decreased by 24%, and the noise of the co-magnetometer at 1 Hz decreased by 33%. The experimental results demonstrate that this method reduces the temperature fluctuation of the OPMSS, effectively suppresses the thermal coupling noise, and thus improves the performance of the SERF co-magnetometer. Moreover, this method is also applicable to other quantum sensors based on alkali metal vapor cell.
Abstract The spin polarization and spatial homogeneity of alkali metal atoms are critical characteristics that determine the performance of spin-exchange relaxation-free magnetometers. In buffer gas cells, these characteristics are influenced by optical broadening and alkali atomic motional restriction imposed by the buffer gas. In coated cells, the protective effect of the coating on atomic spins, combined with rapid atomic diffusion, leads to significantly superior spin polarization characteristics compared to those in high-pressure buffer gas cells. However, due to neglecting the influence of atom-coating interactions on atomic motion, the existing spin polarization and spatial distribution models fail to accurately describe the polarization characteristics in coated cells. In this paper, based on the Langevin–Bloch equation, a dynamic model considering interaction effects between alkali metal atoms and the coating as well as between the pump light and the hyperfine levels of alkali metal atoms is proposed to accurately describe the spin polarization and spatial distribution in coated cells. To validate the proposed model, a series of experiments were carried out. The results demonstrate that coated cells can maintain high spin polarization and spatial homogeneity even under conditions of low pump intensity and high temperature, which are in good agreement with the simulations. This work provides a theoretical reference for the design of high-performance and low-power quantum sensors.
A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.