Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Making the World’s Best Atomic Clock

Jun Ye

Published Jan 1, 2015• 0 citations
Publisher

Abstract

I will report our recent effort towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. We have achieved fractional stability of 2.2 × 10-16 at 1 s for the JILA Sr optical atomic clock. We have also reduced the total uncertainty of our clock to 2.1 × 10-18 in fractional frequency units. Both represent new records for the performance of an atomic clock.

DOI
10.1364/cleo_qels.2015.fth1b.5

Related papers

Operating a 87 Sr optical lattice clock with high precision and at high density

Matthew D. Swallows, Michael J. Martin, Michael Bishof +5 more

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-(16) fractional frequency level. An upgraded laser system has recently been constructed in our lab which may allow the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. To take full advantage of these improvements, it will be necessary to operate a lattice clock with a large number of atoms, and systematic frequency shifts resulting from atomic interactions will become increasingly important. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms and describe a novel method by which such systematic effects can be suppressed.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2012•46 citations

Optical atomic clocks: defining the future of time and frequency metrology

Tara M. Fortier, Andre Nicholas Luiten, Helen S. Margolis

Optical atomic clocks based on laser-cooled trapped ions and atoms have advanced rapidly over the past decade. With fractional frequency uncertainties now surpassing 10 −18 , they are some of the most precise measurement tools ever built. Yet researchers are still pursuing new avenues of research to explore the fundamental limits to their stability, accuracy, and reproducibility. In this mini-review, we provide a survey of the current state of the art by describing the fundamental principles and techniques that underpin this progress, the architectures used to realize optical clocks, and the supporting laser technologies that are essential to their operation. We also examine the progress that has been made toward a redefinition of the second in the International System of Units and the inclusion of optical clocks into the global time and frequency metrology infrastructure. Finally, we discuss emerging applications of optical clocks and look at the prospects for making their precision more readily accessible to end users.

Optica•Dec 10, 2025•17 citations

87Sr optical lattice clocks at JILA

Michael J. Martin, Matthew D. Swallows, Travis Nicholson +5 more

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations

Optical atomic clocks and the quest for ultrastable lasers

F. Riehle

Optical atomic clocks with fractional uncertainties around and below 10−17 [1] and fractional instabilities at one second interrogation time of below 10−15 [2] have outperformed the best microwave clocks like the cesium atomic clock. In optical atomic clocks a highly stable laser is used to interrogate optical transitions in laser-cooled atoms, ions, or molecules. The increase in accuracy and stability of the optical atomic clocks results from the increased line quality factor Q= ν/Δν given by the five orders of magnitude higher frequency of optical transitions as compared to the transition relevant in the microwave domain. To utilize this potential it is furthermore necessary to realize a suitable narrow linewidth of the interrogated line. The linewidth of any optical transition is given by the different broadening mechanisms of the respective quantum transition relevant for particular interrogation process as well as by the coherence properties of the interrogating laser.

Frontiers in Optics•Jan 1, 2013•1 citation

SR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY

Andrew D. Ludlow, Sebastian Blatt, M. BOYD +12 more

We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16

Laser Spectroscopy•Apr 1, 2008•0 citations

Atomic clock frequency ratios with fractional uncertainty $\leq 3.2 \times 10^{-18}$

Alexander Aeppli, Willa J. Arthur-Dworschack, Kyle Beloy +24 more

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in $^{87}$Sr ratios at approximately $1\times10^{-16}$ and the Al$^+$/Yb ratio at $1.6\times10^{-17}$ in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of $1.3 \times 10^{-16}$ at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.

physics.atom-phCross-listedarXiv:2512.21428•Dec 26, 2025
I will report our recent effort towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. We have achieved fractional stability of 2.2 × 10-16 at 1 s for the JILA Sr optical atomic clock. We have also reduced the total uncertainty of our clock to 2.1 × 10-18 in fractional frequency units. Both represent new records for the performance of an atomic clock.
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-(16) fractional frequency level. An upgraded laser system has recently been constructed in our lab which may allow the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. To take full advantage of these improvements, it will be necessary to operate a lattice clock with a large number of atoms, and systematic frequency shifts resulting from atomic interactions will become increasingly important. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms and describe a novel method by which such systematic effects can be suppressed.
Optical atomic clocks based on laser-cooled trapped ions and atoms have advanced rapidly over the past decade. With fractional frequency uncertainties now surpassing 10 −18 , they are some of the most precise measurement tools ever built. Yet researchers are still pursuing new avenues of research to explore the fundamental limits to their stability, accuracy, and reproducibility. In this mini-review, we provide a survey of the current state of the art by describing the fundamental principles and techniques that underpin this progress, the architectures used to realize optical clocks, and the supporting laser technologies that are essential to their operation. We also examine the progress that has been made toward a redefinition of the second in the International System of Units and the inclusion of optical clocks into the global time and frequency metrology infrastructure. Finally, we discuss emerging applications of optical clocks and look at the prospects for making their precision more readily accessible to end users.
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.
Optical atomic clocks with fractional uncertainties around and below 10−17 [1] and fractional instabilities at one second interrogation time of below 10−15 [2] have outperformed the best microwave clocks like the cesium atomic clock. In optical atomic clocks a highly stable laser is used to interrogate optical transitions in laser-cooled atoms, ions, or molecules. The increase in accuracy and stability of the optical atomic clocks results from the increased line quality factor Q= ν/Δν given by the five orders of magnitude higher frequency of optical transitions as compared to the transition relevant in the microwave domain. To utilize this potential it is furthermore necessary to realize a suitable narrow linewidth of the interrogated line. The linewidth of any optical transition is given by the different broadening mechanisms of the respective quantum transition relevant for particular interrogation process as well as by the coherence properties of the interrogating laser.
We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16
Atomic clock frequency ratios with fractional uncertainty ≤3.2×10−18\leq 3.2 \times 10^{-18}≤3.2×10−18
We report high-precision frequency ratio measurements between optical atomic clocks based on 27^{27}27Al+^++, 171^{171}171Yb, and 87^{87}87Sr. With total fractional uncertainties at or below 3.2×10−183.2 \times 10^{-18}3.2×10−18, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in 87^{87}87Sr ratios at approximately 1×10−161\times10^{-16}1×10−16 and the Al+^++/Yb ratio at 1.6×10−171.6\times10^{-17}1.6×10−17 in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of 1.3×10−161.3 \times 10^{-16}1.3×10−16 at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.