Conference on Precision Electromagnetic Measurements

87Sr optical lattice clocks at JILA

Michael J. Martin, Matthew D. Swallows, Travis Nicholson, Michael Bishof, Benjamin Bloom, Jason Williams, Sara Campbell, Jun Ye

Published Jul 1, 2012• 0 citations
Publisher

Abstract

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.

DOI
10.1109/cpem.2012.6250909

Related papers

Operating a 87 Sr optical lattice clock with high precision and at high density

Matthew D. Swallows, Michael J. Martin, Michael Bishof +5 more

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-(16) fractional frequency level. An upgraded laser system has recently been constructed in our lab which may allow the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. To take full advantage of these improvements, it will be necessary to operate a lattice clock with a large number of atoms, and systematic frequency shifts resulting from atomic interactions will become increasingly important. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms and describe a novel method by which such systematic effects can be suppressed.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2012•46 citations

Precision measurement of fermionic collisions using an 87Sr optical lattice clock with 1 × 10-16 inaccuracy

Matthew D. Swallows, Gretchen K. Campbell, Andrew D. Ludlow +6 more

We describe recent progress on the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10(¿16) fractional frequency level. The dominant contributions to the systematic error are from blackbody radiation shifts and collisional shifts. We discuss the blackbody radiation shift and propose measurements and experimental protocols that should reduce its systematic contribution. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms, and experimentally demonstrate how the uncertainty in this density-dependent correction to the clock frequency is reduced.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2010•12 citations

Improvements to a Strontium Optical Lattice Clock

Rees L. McNally

In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.

•Jan 1, 2014•0 citations

Development of an Apparatus for a Strontium Optical Lattice Optical Frequency Standard

Ian R. Hill

Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.

•Jun 1, 2012•3 citations

Understanding atomic interactions in an optical lattice clock and using them to study many-body physics

Michael Bishof

Strontium optical lattice clocks at JILA recently demonstrated record-high accuracy and stability. These advances were enabled by an ultrastable laser with fractional frequency stability of 1x10-16 at 1 second. This laser allows us to study systematic shifts of the 1S0 to 3P0 clock transition with unprecedented precision. Density-dependent frequency shifts represent an unavoidable perturbation for clocks based on many atoms. Our studies of atomic interactions in an optical lattice clock system uncover the nature of these interactions and reveal important many-body atomic correlation effects in this open quantum system. By extending our measurements to all ten nuclear-spin sublevels of the clock states, we observe the first direct evidence of SU(N) symmetric interactions in alkaline earth(-like) atoms. Using the techniques we developed in these studies, we also demonstrate a novel technique for measuring the frequency noise spectrum of an ultrastable laser. We discuss designs for the future direction of our experiment which will place 87Sr atoms within a high finesse cavity that is resonant on the 1S0 to 3P1 transition. We will use this system to study collective effects in cavity quantum electrodynamics. Most notably, strong atom-cavity coupling can enhance the spectroscopic sensitivity of our clock by creating spin-squeezed states via quantum non-demolition measurements. As a precursor to future work studying cavity-mediated collective behavior, we use the unique atomic structure of 88Sr to investigate free-space retarded dipolar coupling in an optically thick sample of atoms.

•Jan 1, 2014•0 citations

SR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY

Andrew D. Ludlow, Sebastian Blatt, M. BOYD +12 more

We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16

Laser Spectroscopy•Apr 1, 2008•0 citations
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-(16) fractional frequency level. An upgraded laser system has recently been constructed in our lab which may allow the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. To take full advantage of these improvements, it will be necessary to operate a lattice clock with a large number of atoms, and systematic frequency shifts resulting from atomic interactions will become increasingly important. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms and describe a novel method by which such systematic effects can be suppressed.
We describe recent progress on the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10(¿16) fractional frequency level. The dominant contributions to the systematic error are from blackbody radiation shifts and collisional shifts. We discuss the blackbody radiation shift and propose measurements and experimental protocols that should reduce its systematic contribution. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms, and experimentally demonstrate how the uncertainty in this density-dependent correction to the clock frequency is reduced.
In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.
Strontium optical lattice clocks at JILA recently demonstrated record-high accuracy and stability. These advances were enabled by an ultrastable laser with fractional frequency stability of 1x10-16 at 1 second. This laser allows us to study systematic shifts of the 1S0 to 3P0 clock transition with unprecedented precision. Density-dependent frequency shifts represent an unavoidable perturbation for clocks based on many atoms. Our studies of atomic interactions in an optical lattice clock system uncover the nature of these interactions and reveal important many-body atomic correlation effects in this open quantum system. By extending our measurements to all ten nuclear-spin sublevels of the clock states, we observe the first direct evidence of SU(N) symmetric interactions in alkaline earth(-like) atoms. Using the techniques we developed in these studies, we also demonstrate a novel technique for measuring the frequency noise spectrum of an ultrastable laser. We discuss designs for the future direction of our experiment which will place 87Sr atoms within a high finesse cavity that is resonant on the 1S0 to 3P1 transition. We will use this system to study collective effects in cavity quantum electrodynamics. Most notably, strong atom-cavity coupling can enhance the spectroscopic sensitivity of our clock by creating spin-squeezed states via quantum non-demolition measurements. As a precursor to future work studying cavity-mediated collective behavior, we use the unique atomic structure of 88Sr to investigate free-space retarded dipolar coupling in an optically thick sample of atoms.
We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16