Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2209.02998 · Physical Review Letters

Quantum Precision Limits of Displacement Noise-Free Interferometers

Tuvia Gefen, Rajashik Tarafder, R. X. Adhikari, Yanbei Chen

Published Jan 8, 2024• 10 citations
arXivHTMLPDF

Abstract

Current laser-interferometric gravitational wave detectors suffer from a fundamental limit to their precision due to the displacement noise of optical elements contributed by various sources. Several schemes for displacement noise-free interferometers (DFI) have been proposed to mitigate their effects. The idea behind these schemes is similar to decoherence-free subspaces in quantum sensing; i.e., certain modes contain information about the gravitational waves but are insensitive to the mirror motion (displacement noise). We derive quantum precision limits for general DFI schemes, including optimal measurement basis and optimal squeezing schemes. We introduce a triangular cavity DFI scheme and apply our general bounds to it. Precision analysis of this scheme with different noise models shows that the DFI property leads to interesting sensitivity profiles and improved precision due to noise mitigation and larger gain from squeezing.

DOI
10.1103/physrevlett.132.020801

Related papers

Gravitational-wave detection beyond the quantum shot-noise limit : the integration of squeezed light in GEO 600

Emil Schreiber

The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.

•Jan 1, 2018•1 citation

Gravitational wave detection using laser interferometry beyond the standard quantum limit

M. Heurs

Interferometric gravitational wave detectors (such as advanced LIGO) employ high-power solid-state lasers to maximize their detection sensitivity and hence their reach into the universe. These sophisticated light sources are ultra-stabilized with regard to output power, emission frequency and beam geometry; this is crucial to obtain low detector noise. However, even when all laser noise is reduced as far as technically possible, unavoidable quantum noise of the laser still remains. This is a consequence of the Heisenberg Uncertainty Principle, the basis of quantum mechanics: in this case, it is fundamentally impossible to simultaneously reduce both the phase noise and the amplitude noise of a laser to arbitrarily low levels. This fact manifests in the detector noise budget as two distinct noise sources—photon shot noise and quantum radiation pressure noise—which together form a lower boundary for current-day gravitational wave detector sensitivities, the standard quantum limit of interferometry. To overcome this limit, various techniques are being proposed, among them different uses of non-classical light and alternative interferometer topologies. This article explains how quantum noise enters and manifests in an interferometric gravitational wave detector, and gives an overview of some of the schemes proposed to overcome this seemingly fundamental limitation, all aimed at the goal of higher gravitational wave event detection rates. This article is part of a discussion meeting issue ‘The promises of gravitational-wave astronomy’.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Apr 16, 2018•10 citations

Noise cancellation properties of displacement noise free interferometer

Shuichi Sato, Seiji Kawamura, A. Nishizawa +1 more

We have demonstrated the practical feasibility of a displacement- and frequency-noise-free laser interferometer (DFI) by partially implementing a recently proposed optical configuration using bi-directional Mach-Zehnder interferometers (MZIs). The noise cancellation efficiency was evaluated by comparing the displacement noise spectrum of the MZIs and the DFI, demonstrating up to 50 dB of noise cancellation. In addition, the possible extension of DFI as QND device is explored.

Journal of Physics Conference Series•May 1, 2010•0 citations

Fundamental sensitivity limit of lossy cavity-enhanced interferometers with external and internal squeezing

M. Korobko, Jan Südbeck, S. Steinlechner +1 more

Quantum optical sensors are ubiquitous in various fields of research, from biological or medical sensors to large-scale experiments searching for dark matter or gravitational waves. Gravitational-wave detectors have been very successful in implementing cavities and quantum squeezed light for enhancing sensitivity to signals from black hole or neutron star mergers. However, the sensitivity to weak forces is limited by the available energy and the optical decoherence in the system. Here, we derive the fundamental sensitivity limit of cavity- and squeezed-light-enhanced interferometers with optical loss. This limit is attained by the optimal use of an additional internal squeeze operation, which allows the mitigation of readout loss. We demonstrate the application of internal squeezing to various scenarios and confirm that it indeed allows one to reach the best sensitivity in cavity- and squeezed-light-enhanced linear force sensors. Our work establishes the groundwork for the future development of optimal sensors in real-world scenarios where, up until now, the application of squeezed light was curtailed by various sources of decoherence.

arXiv:2307.09130•Physical Review A•Dec 6, 2023•7 citations

Quantum enhancement of a 4km laser interferometer gravitational-wave detector

S. Chua

The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.

•Jan 1, 2013•1 citation

Quantum variational measurement and the optical lever intracavity topology of gravitational-wave detectors

Farit Ya. Khalili

The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.

arXiv:gr-qc/0607028•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 19, 2007•6 citations
Current laser-interferometric gravitational wave detectors suffer from a fundamental limit to their precision due to the displacement noise of optical elements contributed by various sources. Several schemes for displacement noise-free interferometers (DFI) have been proposed to mitigate their effects. The idea behind these schemes is similar to decoherence-free subspaces in quantum sensing; i.e., certain modes contain information about the gravitational waves but are insensitive to the mirror motion (displacement noise). We derive quantum precision limits for general DFI schemes, including optimal measurement basis and optimal squeezing schemes. We introduce a triangular cavity DFI scheme and apply our general bounds to it. Precision analysis of this scheme with different noise models shows that the DFI property leads to interesting sensitivity profiles and improved precision due to noise mitigation and larger gain from squeezing.
The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.
Interferometric gravitational wave detectors (such as advanced LIGO) employ high-power solid-state lasers to maximize their detection sensitivity and hence their reach into the universe. These sophisticated light sources are ultra-stabilized with regard to output power, emission frequency and beam geometry; this is crucial to obtain low detector noise. However, even when all laser noise is reduced as far as technically possible, unavoidable quantum noise of the laser still remains. This is a consequence of the Heisenberg Uncertainty Principle, the basis of quantum mechanics: in this case, it is fundamentally impossible to simultaneously reduce both the phase noise and the amplitude noise of a laser to arbitrarily low levels. This fact manifests in the detector noise budget as two distinct noise sources—photon shot noise and quantum radiation pressure noise—which together form a lower boundary for current-day gravitational wave detector sensitivities, the standard quantum limit of interferometry. To overcome this limit, various techniques are being proposed, among them different uses of non-classical light and alternative interferometer topologies. This article explains how quantum noise enters and manifests in an interferometric gravitational wave detector, and gives an overview of some of the schemes proposed to overcome this seemingly fundamental limitation, all aimed at the goal of higher gravitational wave event detection rates. This article is part of a discussion meeting issue ‘The promises of gravitational-wave astronomy’.
Quantum optical sensors are ubiquitous in various fields of research, from biological or medical sensors to large-scale experiments searching for dark matter or gravitational waves. Gravitational-wave detectors have been very successful in implementing cavities and quantum squeezed light for enhancing sensitivity to signals from black hole or neutron star mergers. However, the sensitivity to weak forces is limited by the available energy and the optical decoherence in the system. Here, we derive the fundamental sensitivity limit of cavity- and squeezed-light-enhanced interferometers with optical loss. This limit is attained by the optimal use of an additional internal squeeze operation, which allows the mitigation of readout loss. We demonstrate the application of internal squeezing to various scenarios and confirm that it indeed allows one to reach the best sensitivity in cavity- and squeezed-light-enhanced linear force sensors. Our work establishes the groundwork for the future development of optimal sensors in real-world scenarios where, up until now, the application of squeezed light was curtailed by various sources of decoherence.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.
The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.