Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences

Gravitational wave detection using laser interferometry beyond the standard quantum limit

M. Heurs

Published Apr 16, 2018• 10 citations
Publisher

Abstract

Interferometric gravitational wave detectors (such as advanced LIGO) employ high-power solid-state lasers to maximize their detection sensitivity and hence their reach into the universe. These sophisticated light sources are ultra-stabilized with regard to output power, emission frequency and beam geometry; this is crucial to obtain low detector noise. However, even when all laser noise is reduced as far as technically possible, unavoidable quantum noise of the laser still remains. This is a consequence of the Heisenberg Uncertainty Principle, the basis of quantum mechanics: in this case, it is fundamentally impossible to simultaneously reduce both the phase noise and the amplitude noise of a laser to arbitrarily low levels. This fact manifests in the detector noise budget as two distinct noise sources—photon shot noise and quantum radiation pressure noise—which together form a lower boundary for current-day gravitational wave detector sensitivities, the standard quantum limit of interferometry. To overcome this limit, various techniques are being proposed, among them different uses of non-classical light and alternative interferometer topologies. This article explains how quantum noise enters and manifests in an interferometric gravitational wave detector, and gives an overview of some of the schemes proposed to overcome this seemingly fundamental limitation, all aimed at the goal of higher gravitational wave event detection rates. This article is part of a discussion meeting issue ‘The promises of gravitational-wave astronomy’.

DOI
10.1098/rsta.2017.0289

Related papers

Quantum correlation measurements in interferometric gravitational-wave detectors

V. V. Frolov, S. Kandhasamy, K. Izumi +97 more

Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational-wave detectors, such as the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer.

Physical Review Letters•Apr 1, 2017•0 citations

Gravitational-wave detection beyond the quantum shot-noise limit : the integration of squeezed light in GEO 600

Emil Schreiber

The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.

•Jan 1, 2018•1 citation

Enhanced sensitivity of the LIGO gravitational wave detector by using squeezed states of light

L. Barsotti, S. Biscans, Timothy P. Bodiya +26 more

Nearly a century after Einstein first predicted the existence of gravitational waves, a global network of Earth-based gravitational wave observatories 1-4 is seeking to directly detect this faint radiation using precision laser interferometry. Photon shot noise, due to the quantum nature of light, imposes a fundamental limit on the attometre-level sensitivity of the kilometre-scale Michelson interferometers deployed for this task. Here, we inject squeezed states to improve the performance of one of the detectors of the Laser Interferometer Gravitational-Wave Observatory (LIGO) beyond the quantum noise limit, most notably in the frequency region down to 150 Hz, critically important for several astrophysical sources, with no deterioration of performance observed at any frequency. With the injection of squeezed states, this LIGO detector demonstrated the best broadband sensitivity to gravitational waves ever achieved, with important implications for observing the gravitational-wave Universe with unprecedented sensitivity.

Other repository•Jul 1, 2013•0 citations

Fundamental limits of quantum sensors for gravitational wave detection

S. Gaudio

Abstract Recent advances in quantum sensing—optical clocks at 5.5 × 10 − 19 systematic uncertainty, frequency-dependent squeezing below the standard quantum limit, quantum magnetometers approaching fundamental sensitivity limits—raise a natural question: can these technologies detect gravitational waves directly, or enhance existing detectors beyond current capabilities? We show that the answer is primarily determined by the coupling mechanism between the gravitational wave and the sensor. Starting from the tidal Hamiltonian in Fermi normal coordinates, we identify three physically distinct mechanisms by which a gravitational wave couples directly to a quantum system, and derive their transducer gains within linearized general relativity and non-relativistic quantum mechanics. Internal atomic coupling (tidal distortion of electronic wavefunctions) yields a transducer gain G A = 2.4 × 10 − 20 , with vanishing first-order energy shifts for all J = 0 clock states—a ∼ 10 35 deficit relative to laser interferometry that exceeds any projected quantum enhancement. Center-of-mass coupling (Doppler shifts from geodesic motion) reaches strain sensitivities of ∼ 10 − 18 , still 10 4 above LISA requirements. Light propagation coupling (phase accumulation over macroscopic baselines) provides the enormous transducer gain that makes laser interferometry—and atom interferometry—viable. For detectors exploiting this third mechanism, we quantify how much improvement quantum sensors can provide through the detector’s noise architecture: LISA’s noise budget is predominantly classical, limiting combined quantum enhancement to E ≈ 1.04 , while ground-based detectors in the shot-noise-dominated regime achieve E = 1.6 – 2.1 . Atom interferometers exploit the same light-propagation mechanism to target the 0.01–10 Hz band between the LISA and LIGO ranges.

arXiv:2603.06772•Classical and Quantum Gravity•Aug 3, 2026•1 citation

Quantum limited measurements in gravitational wave detectors

Andrew R. Wade

Gravitational waves manifest as a time varying straining of space: they arise from the accelerating motions of large bodies of mass and propagate across the universe at the speed of light as ripples in the fabric of space-time, a fleetingly weak effect so far eluding direct detection. The detection of gravitation waves is expected to yield a rich vein to observational astronomy, complementing existing electromagnetic surveys and revealing a hitherto unexplored range of phenomena. First generation interferometric gravitational wave detectors, notably Enhanced LIGO, achieved strain sensitivities of one part in ten to power twenty-one per square-root-Hertz at 100 Hz with an expected detection rate of 2-3 events per year. Commissioning of a new generation of Advanced LIGO interferometric detectors has concluded recently with a resultant ten-fold sensitivity improvement. Overall their potential event detection space has increased by a factor of 1000. The quantum nature of light within these detectors now limits their sensitivity over most of their frequency range. This quantum noise limit is driven by the vacuum quadrature fluctuations propagated through their open detection ports and represents a fundamental noise floor to their strain sensitivity. This thesis addresses two distinct approaches to quantum noise improvement for future upgrades to advanced detectors. The first addresses the issue of quantum noise by adopting a quantum non-demolition approach to detector readout variables, the so-called `speed-meter’ design. Such a modified instrument samples test mass momentum, a quantity for which time separated measurements commute and are therefore not bound by Heisenberg-like limits. A novel polarisation-folded sloshing cavity type speed-meter is proposed where readout fields are stored and delayed in the orthogonal polarisation of the interferometer’s arms cavities. Here frequency dependence is selected to cancel position like measurements so that only test mass momentum information remains. A quantum noise propagation model is developed and a sensitivity performance is demonstrated that beats the standard quantum limit below 100 Hz over a broad range of frequencies. A second approach to achieve quantum noise enhancement in advanced detectors involves injection of quadrature-squeezed states in the place of vacuum. This dissertation details the development of a prototype squeezed vacuum source suitable to the demanding enhancement requirements for an Advanced LIGO squeezing installation. The construction of a doubly resonant, bow-tie cavity source is presented. This employs a novel monolithic all-glass cavity construction and is vacuum compatible. This design demonstrates the viability of building a cavity using optical contacting as a construction technique for attaching mounting prisms to highly polished fused-silica breadboards. Such a design can be expected to have excellent length noise stability, provide low intrinsic phase noise and would be suitable to mount on seismic isolation stages within the LIGO vacuum envelope. Further, the travelling wave cavity design should provide excellent 50 dB intrinsic backscatter isolation. We demonstrate the first operation of such a complex non-linear device under vacuum, producing 8.6 dB of measured vacuum squeezing down to 10 Hz across the advanced LIGO ‘audio-band’ detection range.

•Jan 1, 2016•0 citations

Quantum noise reduction for gravitational-wave interferometers with non-classical states

M. J. Yap

The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.

•Jan 1, 2020•0 citations
Interferometric gravitational wave detectors (such as advanced LIGO) employ high-power solid-state lasers to maximize their detection sensitivity and hence their reach into the universe. These sophisticated light sources are ultra-stabilized with regard to output power, emission frequency and beam geometry; this is crucial to obtain low detector noise. However, even when all laser noise is reduced as far as technically possible, unavoidable quantum noise of the laser still remains. This is a consequence of the Heisenberg Uncertainty Principle, the basis of quantum mechanics: in this case, it is fundamentally impossible to simultaneously reduce both the phase noise and the amplitude noise of a laser to arbitrarily low levels. This fact manifests in the detector noise budget as two distinct noise sources—photon shot noise and quantum radiation pressure noise—which together form a lower boundary for current-day gravitational wave detector sensitivities, the standard quantum limit of interferometry. To overcome this limit, various techniques are being proposed, among them different uses of non-classical light and alternative interferometer topologies. This article explains how quantum noise enters and manifests in an interferometric gravitational wave detector, and gives an overview of some of the schemes proposed to overcome this seemingly fundamental limitation, all aimed at the goal of higher gravitational wave event detection rates. This article is part of a discussion meeting issue ‘The promises of gravitational-wave astronomy’.
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational-wave detectors, such as the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer.
The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.
Nearly a century after Einstein first predicted the existence of gravitational waves, a global network of Earth-based gravitational wave observatories 1-4 is seeking to directly detect this faint radiation using precision laser interferometry. Photon shot noise, due to the quantum nature of light, imposes a fundamental limit on the attometre-level sensitivity of the kilometre-scale Michelson interferometers deployed for this task. Here, we inject squeezed states to improve the performance of one of the detectors of the Laser Interferometer Gravitational-Wave Observatory (LIGO) beyond the quantum noise limit, most notably in the frequency region down to 150 Hz, critically important for several astrophysical sources, with no deterioration of performance observed at any frequency. With the injection of squeezed states, this LIGO detector demonstrated the best broadband sensitivity to gravitational waves ever achieved, with important implications for observing the gravitational-wave Universe with unprecedented sensitivity.
Abstract Recent advances in quantum sensing—optical clocks at 5.5 × 10 − 19 systematic uncertainty, frequency-dependent squeezing below the standard quantum limit, quantum magnetometers approaching fundamental sensitivity limits—raise a natural question: can these technologies detect gravitational waves directly, or enhance existing detectors beyond current capabilities? We show that the answer is primarily determined by the coupling mechanism between the gravitational wave and the sensor. Starting from the tidal Hamiltonian in Fermi normal coordinates, we identify three physically distinct mechanisms by which a gravitational wave couples directly to a quantum system, and derive their transducer gains within linearized general relativity and non-relativistic quantum mechanics. Internal atomic coupling (tidal distortion of electronic wavefunctions) yields a transducer gain G A = 2.4 × 10 − 20 , with vanishing first-order energy shifts for all J = 0 clock states—a ∼ 10 35 deficit relative to laser interferometry that exceeds any projected quantum enhancement. Center-of-mass coupling (Doppler shifts from geodesic motion) reaches strain sensitivities of ∼ 10 − 18 , still 10 4 above LISA requirements. Light propagation coupling (phase accumulation over macroscopic baselines) provides the enormous transducer gain that makes laser interferometry—and atom interferometry—viable. For detectors exploiting this third mechanism, we quantify how much improvement quantum sensors can provide through the detector’s noise architecture: LISA’s noise budget is predominantly classical, limiting combined quantum enhancement to E ≈ 1.04 , while ground-based detectors in the shot-noise-dominated regime achieve E = 1.6 – 2.1 . Atom interferometers exploit the same light-propagation mechanism to target the 0.01–10 Hz band between the LISA and LIGO ranges.
Gravitational waves manifest as a time varying straining of space: they arise from the accelerating motions of large bodies of mass and propagate across the universe at the speed of light as ripples in the fabric of space-time, a fleetingly weak effect so far eluding direct detection. The detection of gravitation waves is expected to yield a rich vein to observational astronomy, complementing existing electromagnetic surveys and revealing a hitherto unexplored range of phenomena. First generation interferometric gravitational wave detectors, notably Enhanced LIGO, achieved strain sensitivities of one part in ten to power twenty-one per square-root-Hertz at 100 Hz with an expected detection rate of 2-3 events per year. Commissioning of a new generation of Advanced LIGO interferometric detectors has concluded recently with a resultant ten-fold sensitivity improvement. Overall their potential event detection space has increased by a factor of 1000. The quantum nature of light within these detectors now limits their sensitivity over most of their frequency range. This quantum noise limit is driven by the vacuum quadrature fluctuations propagated through their open detection ports and represents a fundamental noise floor to their strain sensitivity. This thesis addresses two distinct approaches to quantum noise improvement for future upgrades to advanced detectors. The first addresses the issue of quantum noise by adopting a quantum non-demolition approach to detector readout variables, the so-called `speed-meter’ design. Such a modified instrument samples test mass momentum, a quantity for which time separated measurements commute and are therefore not bound by Heisenberg-like limits. A novel polarisation-folded sloshing cavity type speed-meter is proposed where readout fields are stored and delayed in the orthogonal polarisation of the interferometer’s arms cavities. Here frequency dependence is selected to cancel position like measurements so that only test mass momentum information remains. A quantum noise propagation model is developed and a sensitivity performance is demonstrated that beats the standard quantum limit below 100 Hz over a broad range of frequencies. A second approach to achieve quantum noise enhancement in advanced detectors involves injection of quadrature-squeezed states in the place of vacuum. This dissertation details the development of a prototype squeezed vacuum source suitable to the demanding enhancement requirements for an Advanced LIGO squeezing installation. The construction of a doubly resonant, bow-tie cavity source is presented. This employs a novel monolithic all-glass cavity construction and is vacuum compatible. This design demonstrates the viability of building a cavity using optical contacting as a construction technique for attaching mounting prisms to highly polished fused-silica breadboards. Such a design can be expected to have excellent length noise stability, provide low intrinsic phase noise and would be suitable to mount on seismic isolation stages within the LIGO vacuum envelope. Further, the travelling wave cavity design should provide excellent 50 dB intrinsic backscatter isolation. We demonstrate the first operation of such a complex non-linear device under vacuum, producing 8.6 dB of measured vacuum squeezing down to 10 Hz across the advanced LIGO ‘audio-band’ detection range.
The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.