arXiv:gr-qc/0607028 · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields

Quantum variational measurement and the optical lever intracavity topology of gravitational-wave detectors

Farit Ya. Khalili

Published Apr 19, 2007• 6 citations
arXivHTMLPDF

Abstract

The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.

DOI
10.1103/physrevd.75.082003

Related papers

Practical design of the optical lever intracavity topology of gravitational-wave detectors

S. L. Danilishin, F. Ya. Khalili

The quantum nondemolition (QND) intracavity topologies of gravitational-wave detectors proposed several years ago allow us, in principle, to obtain sensitivity significantly better than the standard quantum limit using relatively small amount of optical pumping power. In this article we consider an improved more practical version of the optical lever intracavity scheme. It differs from the original version by the symmetry which allows to suppress influence of the input light amplitude fluctuation. In addition, it provides the means to inject optical pumping inside the scheme without increase of optical losses. We consider also sensitivity limitations imposed by the local meter which is the key element of the intracavity topologies. Two variants of the local meter are analyzed, which are based on the spectral variation measurement and on the discrete sampling variation measurement, correspondingly. The former one, while can not be considered as a candidate for a practical implementation, allows, in principle, to obtain the best sensitivity and thus can be considered as an ideal ``asymptotic case'' for all other schemes. The DSVM-based local meter can be considered as a realistic scheme but its sensitivity, unfortunately, is by far not so good just due to a couple of peculiar numeric factors specific for this scheme. From our point of view search of new methods of mechanical QND measurements probably based on improved DSVM scheme or which combine the local meter with the pondermotive squeezing technique, is necessary.

arXiv:gr-qc/0508022•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Jan 19, 2006•17 citations

Quantum variational measurement in the next generation gravitational-wave detectors

F. Ya. Khalili

A relatively simple method of overcoming the standard quantum limit in the next generation Advanced LIGO gravitational-wave detector is considered. It is based on the quantum variational measurement with a single, short (a few tens of meters) filter cavity. Estimates show that this method allows one to reduce the radiation-pressure noise at low frequencies ($<100\text{ }\text{ }\mathrm{Hz}$) to the level comparable with or smaller than the low-frequency noises of nonquantum origin (mirrors' suspension noise, mirrors' thermal noise, seismic noise, and gravity gradients fluctuations).

arXiv:gr-qc/0609058•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Nov 14, 2007•19 citations

Surpassing the Standard Quantum Limit using an Optical Spring

T. J. Cullen, Scott Aronson, Ronald Pagano +9 more

Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements impose a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a back-action evading measurement technique, or else exploit cancellations of any excess noise contributions at the detector. %Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL measurement sensitivity nearly two times better than previous measurements, and with architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. By exploiting quantum correlations created by an optical spring, we measure a total sensitivity below the SQL by $\textbf{2.8}$ dB, corresponding to a reduction in the noise power by $\textbf{72}\pm\textbf{5.1}$ \% below the quantum limit. Through the use of a detuned optical spring, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies ranges applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the universe.

arXiv:2210.12222•Oct 21, 2022•1 citation

Optical quantuma non-demolition meter for gravitational wave detection

S. L. Danilishin, Farid Ya Khalili

We propose new gravitational wave detector design and new method of measurement that is based on principle of quantum non-demolition (QND) measurement. New design implies the so called "intracavity" measurement of the optical field parameters inside the cavity of interferometer without disturbing light quantum state. It is shown that using a technique called discrete sampling variation measurement (DSVM) in a local meter it is possible to overcome the standard quantum limit by an arbitrary amount limited only by the amount of optical energy circulating in the cavity of local meter and optical losses in the local meter mirrors. This technique being implemented will also be a demonstration of QND measurement and therefore can be used to demonstrate the detector moveable mirrors quantum behaviour.

CAOL . International Conference on Advanced Optoelectronics and Lasers•Jan 5, 2006•0 citations

Surpassing the Standard Quantum Limit Using an Optical Spring

T. J. Cullen, Ronald Pagano, Scott Aronson +9 more

Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.

Physical Review Letters•Sep 13, 2024•4 citations

Backaction Amplification and Quantum Limits in Optomechanical Measurements

P. Verlot, Alexandros Tavernarakis, Tristan Briant +2 more

Optical interferometry is by far the most sensitive displacement measurement technique available, with sensitivities at the 10(-20) m/square root(Hz) level in the large-scale gravitational-wave interferometers currently in operation. Second-generation interferometers will experience a tenfold improvement in sensitivity and be mainly limited by quantum noise, close to the standard quantum limit (SQL), once considered as the ultimate displacement sensitivity achievable by interferometry. In this Letter, we experimentally demonstrate one of the techniques envisioned to go beyond the SQL: amplification of a signal by radiation-pressure backaction in a detuned cavity.

arXiv:0912.4085•Physical Review Letters•Mar 31, 2010•101 citations
The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.
The quantum nondemolition (QND) intracavity topologies of gravitational-wave detectors proposed several years ago allow us, in principle, to obtain sensitivity significantly better than the standard quantum limit using relatively small amount of optical pumping power. In this article we consider an improved more practical version of the optical lever intracavity scheme. It differs from the original version by the symmetry which allows to suppress influence of the input light amplitude fluctuation. In addition, it provides the means to inject optical pumping inside the scheme without increase of optical losses. We consider also sensitivity limitations imposed by the local meter which is the key element of the intracavity topologies. Two variants of the local meter are analyzed, which are based on the spectral variation measurement and on the discrete sampling variation measurement, correspondingly. The former one, while can not be considered as a candidate for a practical implementation, allows, in principle, to obtain the best sensitivity and thus can be considered as an ideal ``asymptotic case'' for all other schemes. The DSVM-based local meter can be considered as a realistic scheme but its sensitivity, unfortunately, is by far not so good just due to a couple of peculiar numeric factors specific for this scheme. From our point of view search of new methods of mechanical QND measurements probably based on improved DSVM scheme or which combine the local meter with the pondermotive squeezing technique, is necessary.
A relatively simple method of overcoming the standard quantum limit in the next generation Advanced LIGO gravitational-wave detector is considered. It is based on the quantum variational measurement with a single, short (a few tens of meters) filter cavity. Estimates show that this method allows one to reduce the radiation-pressure noise at low frequencies (<100  Hz<100\text{ }\text{ }\mathrm{Hz}<100  Hz) to the level comparable with or smaller than the low-frequency noises of nonquantum origin (mirrors' suspension noise, mirrors' thermal noise, seismic noise, and gravity gradients fluctuations).
Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements impose a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a back-action evading measurement technique, or else exploit cancellations of any excess noise contributions at the detector. %Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL measurement sensitivity nearly two times better than previous measurements, and with architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. By exploiting quantum correlations created by an optical spring, we measure a total sensitivity below the SQL by 2.8\textbf{2.8}2.8 dB, corresponding to a reduction in the noise power by 72±5.1\textbf{72}\pm\textbf{5.1}72±5.1 \% below the quantum limit. Through the use of a detuned optical spring, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies ranges applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the universe.
We propose new gravitational wave detector design and new method of measurement that is based on principle of quantum non-demolition (QND) measurement. New design implies the so called "intracavity" measurement of the optical field parameters inside the cavity of interferometer without disturbing light quantum state. It is shown that using a technique called discrete sampling variation measurement (DSVM) in a local meter it is possible to overcome the standard quantum limit by an arbitrary amount limited only by the amount of optical energy circulating in the cavity of local meter and optical losses in the local meter mirrors. This technique being implemented will also be a demonstration of QND measurement and therefore can be used to demonstrate the detector moveable mirrors quantum behaviour.
Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.
Optical interferometry is by far the most sensitive displacement measurement technique available, with sensitivities at the 10(-20) m/square root(Hz) level in the large-scale gravitational-wave interferometers currently in operation. Second-generation interferometers will experience a tenfold improvement in sensitivity and be mainly limited by quantum noise, close to the standard quantum limit (SQL), once considered as the ultimate displacement sensitivity achievable by interferometry. In this Letter, we experimentally demonstrate one of the techniques envisioned to go beyond the SQL: amplification of a signal by radiation-pressure backaction in a detuned cavity.