Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0912.4085 · Physical Review Letters

Backaction Amplification and Quantum Limits in Optomechanical Measurements

P. Verlot, Alexandros Tavernarakis, Tristan Briant, P.-F. Cohadon, A. Heidmann

Published Mar 31, 2010• 101 citations
arXivHTMLPDF

Abstract

Optical interferometry is by far the most sensitive displacement measurement technique available, with sensitivities at the 10(-20) m/square root(Hz) level in the large-scale gravitational-wave interferometers currently in operation. Second-generation interferometers will experience a tenfold improvement in sensitivity and be mainly limited by quantum noise, close to the standard quantum limit (SQL), once considered as the ultimate displacement sensitivity achievable by interferometry. In this Letter, we experimentally demonstrate one of the techniques envisioned to go beyond the SQL: amplification of a signal by radiation-pressure backaction in a detuned cavity.

DOI
10.1103/physrevlett.104.133602

Related papers

Surpassing the Standard Quantum Limit Using an Optical Spring

T. J. Cullen, Ronald Pagano, Scott Aronson +9 more

Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.

Physical Review Letters•Sep 13, 2024•4 citations

Improving Broadband Displacement Detection with Quantum Correlations

N. S. Kampel, Robert W. Peterson, Ran Fischer +5 more

Interferometers enable ultrasensitive measurement in a wide array of applications from gravitational wave searches to force microscopes. The role of quantum mechanics in the metrological limits of interferometers has a rich history, and a large number of techniques to surpass conventional limits have been proposed. In a typical measurement configuration, the trade-off between the probe’s shot noise (imprecision) and its quantum backaction results in what is known as the standard quantum limit (SQL). In this work, we investigate how quantum correlations accessed by modifying the readout of the interferometer can access physics beyond the SQL and improve displacement sensitivity. Specifically, we use an optical cavity to probe the motion of a silicon nitride membrane off mechanical resonance, as one would do in a broadband displacement or force measurement, and observe sensitivity better than the SQL dictates for our quantum efficiency. Our measurement illustrates the core idea behind a technique known as variational readout, in which the optical readout quadrature is changed as a function of frequency to improve broadband displacement detection. And, more generally, our result is a salient example of how correlations can aid sensing in the presence of backaction.

•Apr 18, 2017•36 citations

Surpassing the Standard Quantum Limit using an Optical Spring

T. J. Cullen, Scott Aronson, Ronald Pagano +9 more

Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements impose a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a back-action evading measurement technique, or else exploit cancellations of any excess noise contributions at the detector. %Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL measurement sensitivity nearly two times better than previous measurements, and with architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. By exploiting quantum correlations created by an optical spring, we measure a total sensitivity below the SQL by $\textbf{2.8}$ dB, corresponding to a reduction in the noise power by $\textbf{72}\pm\textbf{5.1}$ \% below the quantum limit. Through the use of a detuned optical spring, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies ranges applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the universe.

arXiv:2210.12222•Oct 21, 2022•1 citation

Harnessing quantum correlations for physics beyond the standard quantum limit in broadband displacement detection

N. S. Kampel, Robert W. Peterson, Ran Fischer +5 more

When one seeks knowledge of the full dynamics of the displacement of a harmonic oscillator, non-commutation of the two mechanical quadratures requires a minimum added noise equal to the mechanical resonator's zero point motion. This fundamental quantum limit (QL) is a distinct bound from the standard quantum limit (SQL) that is often considered in interferometric displacement measurement. The SQL is a consequence of the non-commutation of the probe's quadratures in a specific measurement configuration and is characterized by a tradeoff between shot noise (SN) imprecision and quantum backaction that are uncorrelated. The QL and SQL reach the same limit when probing at the peak mechanical response, but the QL can be a significantly lower bound off resonance. In studies of micro-mechanical motion, there has been great interest in observing quantum backaction and approaching the SQL on mechanical resonance. However, much of what historically motivates SQL research is displacement monitoring over a wide frequency band, such as gravitational wave searches. One long-standing concept for surpassing the SQL is to introduce correlations by changing the readout quadrature as a function of frequency in a technique known as variational readout. Here we harness quantum correlations in the measurement of a macroscopic resonator by modifying the readout quadrature of an optical interferometer. By using an optomechanical device thermalized to a dilution refrigerator, we measure quantum noise far off resonance where we improve upon the off-resonance SQL for our quantum efficiency.

•Jul 22, 2016•2 citations

Quantum variational measurement and the optical lever intracavity topology of gravitational-wave detectors

Farit Ya. Khalili

The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.

arXiv:gr-qc/0607028•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 19, 2007•6 citations

Observation of radiation-pressure effects and back-action cancellation in interferometric measurements

A. Heidmann, T. Caniard, P. Verlot +2 more

Radiation pressure exerted by light in interferometric measurements is responsible for displacements of mirrors which appear as an additional back-action noise and limit the sensitivity of the measurement. We experimentally study these effects by monitoring in a very highfinesse optical cavity the displacements of a mirror with a sensitivity at the 10-20 m/√Hz level. This unique sensitivity is a step towards the first observation of the fundamental quantum effects of radiation pressure and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes, and we already report the first experimental demonstration of a back-action noise cancellation. Using a classical radiation-pressure noise to mimic the quantum noise of light, we have observed a drastic improvement of sensitivity both in position and force measurements.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 8, 2008•0 citations
Optical interferometry is by far the most sensitive displacement measurement technique available, with sensitivities at the 10(-20) m/square root(Hz) level in the large-scale gravitational-wave interferometers currently in operation. Second-generation interferometers will experience a tenfold improvement in sensitivity and be mainly limited by quantum noise, close to the standard quantum limit (SQL), once considered as the ultimate displacement sensitivity achievable by interferometry. In this Letter, we experimentally demonstrate one of the techniques envisioned to go beyond the SQL: amplification of a signal by radiation-pressure backaction in a detuned cavity.
Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.
Interferometers enable ultrasensitive measurement in a wide array of applications from gravitational wave searches to force microscopes. The role of quantum mechanics in the metrological limits of interferometers has a rich history, and a large number of techniques to surpass conventional limits have been proposed. In a typical measurement configuration, the trade-off between the probe’s shot noise (imprecision) and its quantum backaction results in what is known as the standard quantum limit (SQL). In this work, we investigate how quantum correlations accessed by modifying the readout of the interferometer can access physics beyond the SQL and improve displacement sensitivity. Specifically, we use an optical cavity to probe the motion of a silicon nitride membrane off mechanical resonance, as one would do in a broadband displacement or force measurement, and observe sensitivity better than the SQL dictates for our quantum efficiency. Our measurement illustrates the core idea behind a technique known as variational readout, in which the optical readout quadrature is changed as a function of frequency to improve broadband displacement detection. And, more generally, our result is a salient example of how correlations can aid sensing in the presence of backaction.
Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements impose a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a back-action evading measurement technique, or else exploit cancellations of any excess noise contributions at the detector. %Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL measurement sensitivity nearly two times better than previous measurements, and with architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. By exploiting quantum correlations created by an optical spring, we measure a total sensitivity below the SQL by 2.8\textbf{2.8}2.8 dB, corresponding to a reduction in the noise power by 72±5.1\textbf{72}\pm\textbf{5.1}72±5.1 \% below the quantum limit. Through the use of a detuned optical spring, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies ranges applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the universe.
When one seeks knowledge of the full dynamics of the displacement of a harmonic oscillator, non-commutation of the two mechanical quadratures requires a minimum added noise equal to the mechanical resonator's zero point motion. This fundamental quantum limit (QL) is a distinct bound from the standard quantum limit (SQL) that is often considered in interferometric displacement measurement. The SQL is a consequence of the non-commutation of the probe's quadratures in a specific measurement configuration and is characterized by a tradeoff between shot noise (SN) imprecision and quantum backaction that are uncorrelated. The QL and SQL reach the same limit when probing at the peak mechanical response, but the QL can be a significantly lower bound off resonance. In studies of micro-mechanical motion, there has been great interest in observing quantum backaction and approaching the SQL on mechanical resonance. However, much of what historically motivates SQL research is displacement monitoring over a wide frequency band, such as gravitational wave searches. One long-standing concept for surpassing the SQL is to introduce correlations by changing the readout quadrature as a function of frequency in a technique known as variational readout. Here we harness quantum correlations in the measurement of a macroscopic resonator by modifying the readout quadrature of an optical interferometer. By using an optomechanical device thermalized to a dilution refrigerator, we measure quantum noise far off resonance where we improve upon the off-resonance SQL for our quantum efficiency.
The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.
Radiation pressure exerted by light in interferometric measurements is responsible for displacements of mirrors which appear as an additional back-action noise and limit the sensitivity of the measurement. We experimentally study these effects by monitoring in a very highfinesse optical cavity the displacements of a mirror with a sensitivity at the 10-20 m/√Hz level. This unique sensitivity is a step towards the first observation of the fundamental quantum effects of radiation pressure and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes, and we already report the first experimental demonstration of a back-action noise cancellation. Using a classical radiation-pressure noise to mimic the quantum noise of light, we have observed a drastic improvement of sensitivity both in position and force measurements.