Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2207.03668 · Journal of Physics A Mathematical and Theoretical

Quality analysis for precision metrology based on joint weak measurements without discarding readout data

Lupei Qin, Luting Xu, Xin-Qi Li

Published May 25, 2023• 2 citations
arXivHTMLPDF

Abstract

Abstract We present a theoretical analysis for the metrology quality of joint weak measurements (JWMs), in close comparison with the weak-value-amplification technique. We point out that the difference probability function employed in the JWM scheme cannot be used to calculate the uncertainty variance and Fisher information (FI). In order to carry out the metrological precision, we reformulate the problem in terms of difference-combined stochastic variables, which makes all calculations well defined. We reveal that, in general, the metrological precision of the JWM scheme cannot reach that indicated by the total FI, despite that all the readouts are collected without discarding. We also analyze the effect of technical noise, showing that the technical noise cannot be removed by the subtracting procedure, which yet can be utilized to outperform the conventional measurement, when considering the imaginary weak value measurement.

DOI
10.1088/1751-8121/acd919

Related papers

Quantum-coherence-free precision metrology by means of difference-signal amplification

Jialin Li, Yazhi Niu, Xinyi Wang +2 more

The novel weak-value-amplification (WVA) scheme of precision metrology is deeply rooted in the quantum nature of destructive interference between the pre- and post-selection states. And, an alternative version, termed as joint WVA (JWVA), which employs the difference-signal from the post-selection accepted and rejected results, has been found possible to achieve even better sensitivity (two orders of magnitude higher) under some technical limitations (e.g. misalignment errors). In this work, after erasing the quantum coherence, we analyze the difference-signal amplification (DSA) technique, which serves as a classical counterpart of the JWVA, and show that similar amplification effect can be achieved. We obtain a simple expression for the amplified signal, carry out characterization of precision, and point out the optimal working regime. We also discuss how to implement the post-selection of a classical mixed state. The proposed classical DSA technique holds similar technical advantages of the JWVA and may find interesting applications in practice.

arXiv:2212.13729•Scientific Reports•Mar 22, 2023•0 citations

Fisher information analysis on weak-value-amplification metrology using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.

arXiv:2201.13016•Physical Review A•Aug 30, 2022•21 citations

Weak-value-amplification metrology without spectral analysis

Jingzheng Huang, Chen Fang, Guihua Zeng

We propose a scheme called difference weak measurement, and we illustrate its advantages for measuring a small longitude phase shift in high precision. Compared to the standard interferometry and standard weak measurement schemes, the proposed scheme has a much higher resolution in the presence of various practical imperfections, such as alignment error and light intensity variation error. Moreover, we highlight the advantage of utilizing a complex weak value, where its imaginary part can reduce the harmful effect induced by channel decoherence. Finally, we propose a closed-loop scenario to solve the narrow dynamic range problem that exists in the current weak measurement schemes. The difference weak measurement scheme simultaneously fulfills the requirements of high precision, wide dynamic range, and strong robustness, which makes it a powerfully practical tool for phase-shift measurement and other metrological tasks.

arXiv:1803.08637•Physical Review A•Jun 26, 2018•15 citations

Classical-correlation-enhanced weak-value amplification resilient to persistent noises

Xu-Song Hong, Gong-Chu Li, Lei Chen +8 more

Weak measurement (WM) offers the advantage of amplifying small signals at the cost of postselecting a small portion of the probes. This so-called weak-value amplification effect makes it compare favorably with conventional techniques (without postselection) to overcome various technical noises. However, certain types of technical noise, such as jitter and pixelation, present insurmountable limitations for both WM and conventional techniques. In this work, we propose an advanced variant of WM that incorporates time-momentum correlation (TMC) into biased weak measurement (BWM). By employing the Fisher information metric, we theoretically show that TMC-BWM can overcome jitter and pixelation, and meanwhile extract significantly higher Fisher information. This dual advantage was experimentally validated in a magnetic-sensing application when applying severe jitter and pixelation, and it remains robust under natural conditions, achieving a 24.8-dB improvement in precision over the standard WM scheme. Moreover, merely classical resources are required to achieve this dual metrological advantage.

Physical Review Applied•Mar 10, 2026•0 citations

Weak Value Amplification Can Outperform Conventional Measurement in the Presence of Detector Saturation

Jérémie Harris, Robert W. Boyd, Jeff S. Lundeen

Weak value amplification (WVA) is a technique by which one can magnify the apparent strength of a measurement signal. Some have claimed that WVA can outperform more conventional measurement schemes in parameter estimation. Nonetheless, a significant body of theoretical work has challenged this perspective, suggesting WVA to be fundamentally suboptimal. Optimal measurements may not be practical, however. Two practical considerations that have been conjectured to afford a benefit to WVA over conventional measurement are certain types of noise and detector saturation. Here, we report a theoretical study of the role of saturation and pixel noise in WVA-based measurement, in which we carry out a Bayesian analysis of the Fisher information available using a saturable, pixelated, digitized, and/or noisy detector. We draw two conclusions: first, that saturation alone does not confer an advantage to the WVA approach over conventional measurement, and second, that WVA can outperform conventional measurement when saturation is combined with intrinsic pixel noise and/or digitization.

arXiv:1612.04327•Physical Review Letters•Feb 15, 2017•134 citations

Optimization of parameter measurement precision with precoupling-assisted weak-value amplification

Manchao Zhang, Jie Zhang, Chun-Wang Wu +4 more

The weak-value amplification is extensively considered in precision metrology in order to achieve a higher sensitivity. Despite the practical benefits in amplifying small physical quantities, its metrological advantage still arouses a broad debate due to the low postselection probability of success. In this paper, by employing the quantum Fisher information metric, we show that the precision of estimating an unknown parameter can be improved by introducing a precoupling process with properly chosen interaction operators. We point out this result is credible for both real and imaginary weak values. By tracking the meter wave functions, we find this enhancement of estimation precision comes from a precoupling induced modulation of the meter wave function, thus the most sensitive regime with respect to the parameter is reached. In addition, the estimation error is investigated by considering the difference between the theoretical and estimated value. The analysis suggests that this kind of error can be effectively suppressed by averaging the estimations resulted from different initial meter states. These results are finally illustrated by an exact numerical simulation where the advantages of our proposal are displayed by the comparison to the standard weak-value amplification scheme.

Physical Review A•Apr 3, 2023•5 citations
Abstract We present a theoretical analysis for the metrology quality of joint weak measurements (JWMs), in close comparison with the weak-value-amplification technique. We point out that the difference probability function employed in the JWM scheme cannot be used to calculate the uncertainty variance and Fisher information (FI). In order to carry out the metrological precision, we reformulate the problem in terms of difference-combined stochastic variables, which makes all calculations well defined. We reveal that, in general, the metrological precision of the JWM scheme cannot reach that indicated by the total FI, despite that all the readouts are collected without discarding. We also analyze the effect of technical noise, showing that the technical noise cannot be removed by the subtracting procedure, which yet can be utilized to outperform the conventional measurement, when considering the imaginary weak value measurement.
The novel weak-value-amplification (WVA) scheme of precision metrology is deeply rooted in the quantum nature of destructive interference between the pre- and post-selection states. And, an alternative version, termed as joint WVA (JWVA), which employs the difference-signal from the post-selection accepted and rejected results, has been found possible to achieve even better sensitivity (two orders of magnitude higher) under some technical limitations (e.g. misalignment errors). In this work, after erasing the quantum coherence, we analyze the difference-signal amplification (DSA) technique, which serves as a classical counterpart of the JWVA, and show that similar amplification effect can be achieved. We obtain a simple expression for the amplified signal, carry out characterization of precision, and point out the optimal working regime. We also discuss how to implement the post-selection of a classical mixed state. The proposed classical DSA technique holds similar technical advantages of the JWVA and may find interesting applications in practice.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.
We propose a scheme called difference weak measurement, and we illustrate its advantages for measuring a small longitude phase shift in high precision. Compared to the standard interferometry and standard weak measurement schemes, the proposed scheme has a much higher resolution in the presence of various practical imperfections, such as alignment error and light intensity variation error. Moreover, we highlight the advantage of utilizing a complex weak value, where its imaginary part can reduce the harmful effect induced by channel decoherence. Finally, we propose a closed-loop scenario to solve the narrow dynamic range problem that exists in the current weak measurement schemes. The difference weak measurement scheme simultaneously fulfills the requirements of high precision, wide dynamic range, and strong robustness, which makes it a powerfully practical tool for phase-shift measurement and other metrological tasks.
Weak measurement (WM) offers the advantage of amplifying small signals at the cost of postselecting a small portion of the probes. This so-called weak-value amplification effect makes it compare favorably with conventional techniques (without postselection) to overcome various technical noises. However, certain types of technical noise, such as jitter and pixelation, present insurmountable limitations for both WM and conventional techniques. In this work, we propose an advanced variant of WM that incorporates time-momentum correlation (TMC) into biased weak measurement (BWM). By employing the Fisher information metric, we theoretically show that TMC-BWM can overcome jitter and pixelation, and meanwhile extract significantly higher Fisher information. This dual advantage was experimentally validated in a magnetic-sensing application when applying severe jitter and pixelation, and it remains robust under natural conditions, achieving a 24.8-dB improvement in precision over the standard WM scheme. Moreover, merely classical resources are required to achieve this dual metrological advantage.
Weak value amplification (WVA) is a technique by which one can magnify the apparent strength of a measurement signal. Some have claimed that WVA can outperform more conventional measurement schemes in parameter estimation. Nonetheless, a significant body of theoretical work has challenged this perspective, suggesting WVA to be fundamentally suboptimal. Optimal measurements may not be practical, however. Two practical considerations that have been conjectured to afford a benefit to WVA over conventional measurement are certain types of noise and detector saturation. Here, we report a theoretical study of the role of saturation and pixel noise in WVA-based measurement, in which we carry out a Bayesian analysis of the Fisher information available using a saturable, pixelated, digitized, and/or noisy detector. We draw two conclusions: first, that saturation alone does not confer an advantage to the WVA approach over conventional measurement, and second, that WVA can outperform conventional measurement when saturation is combined with intrinsic pixel noise and/or digitization.
The weak-value amplification is extensively considered in precision metrology in order to achieve a higher sensitivity. Despite the practical benefits in amplifying small physical quantities, its metrological advantage still arouses a broad debate due to the low postselection probability of success. In this paper, by employing the quantum Fisher information metric, we show that the precision of estimating an unknown parameter can be improved by introducing a precoupling process with properly chosen interaction operators. We point out this result is credible for both real and imaginary weak values. By tracking the meter wave functions, we find this enhancement of estimation precision comes from a precoupling induced modulation of the meter wave function, thus the most sensitive regime with respect to the parameter is reached. In addition, the estimation error is investigated by considering the difference between the theoretical and estimated value. The analysis suggests that this kind of error can be effectively suppressed by averaging the estimations resulted from different initial meter states. These results are finally illustrated by an exact numerical simulation where the advantages of our proposal are displayed by the comparison to the standard weak-value amplification scheme.