Classical-correlation-enhanced weak-value amplification resilient to persistent noises

Xu-Song Hong, Gong-Chu Li, Lei Chen, Si-Qi Zhang, XU Hua-qin, Yuancheng Liu, Shengshi Pang, Andrew N. Jordan, Geng Chen, Chuan‐Feng Li, Guang‐Can Guo

Published Mar 10, 2026• 0 citations
Publisher

Abstract

Weak measurement (WM) offers the advantage of amplifying small signals at the cost of postselecting a small portion of the probes. This so-called weak-value amplification effect makes it compare favorably with conventional techniques (without postselection) to overcome various technical noises. However, certain types of technical noise, such as jitter and pixelation, present insurmountable limitations for both WM and conventional techniques. In this work, we propose an advanced variant of WM that incorporates time-momentum correlation (TMC) into biased weak measurement (BWM). By employing the Fisher information metric, we theoretically show that TMC-BWM can overcome jitter and pixelation, and meanwhile extract significantly higher Fisher information. This dual advantage was experimentally validated in a magnetic-sensing application when applying severe jitter and pixelation, and it remains robust under natural conditions, achieving a 24.8-dB improvement in precision over the standard WM scheme. Moreover, merely classical resources are required to achieve this dual metrological advantage.

DOI
10.1103/755l-23f6

Related papers

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Adaptive weak-value amplification with adjustable postselection

Fei Li, Jingzheng Huang, Guihua Zeng

Weak-value amplification (WVA) has recently become an important technique for parameter estimation, owing to its ability to enhance the signal-to-noise ratio by amplifying extremely small signals with proper postselection strategies. In this paper, we propose an adaptive WVA scheme to achieve the highest Fisher information when using an unbalanced pointer. Different from previous schemes, the adaptive WVA scheme is associated with a real-time update on the postselection states with the help of feedback information from the outcomes, and the ``extremely small'' condition set on the parameter of interest is relaxed. By applying this scheme to a time-delay measurement scenario, we show by numerical simulation that the precision achieved in our scheme is several times higher than the standard WVA scheme. Our result might open a path for improving the WVA technique in a more flexible and robust way.

arXiv:1803.09421•Physical Review A•Sep 15, 2017•23 citations

Weak Value Amplification Can Outperform Conventional Measurement in the Presence of Detector Saturation

Jérémie Harris, Robert W. Boyd, Jeff S. Lundeen

Weak value amplification (WVA) is a technique by which one can magnify the apparent strength of a measurement signal. Some have claimed that WVA can outperform more conventional measurement schemes in parameter estimation. Nonetheless, a significant body of theoretical work has challenged this perspective, suggesting WVA to be fundamentally suboptimal. Optimal measurements may not be practical, however. Two practical considerations that have been conjectured to afford a benefit to WVA over conventional measurement are certain types of noise and detector saturation. Here, we report a theoretical study of the role of saturation and pixel noise in WVA-based measurement, in which we carry out a Bayesian analysis of the Fisher information available using a saturable, pixelated, digitized, and/or noisy detector. We draw two conclusions: first, that saturation alone does not confer an advantage to the WVA approach over conventional measurement, and second, that WVA can outperform conventional measurement when saturation is combined with intrinsic pixel noise and/or digitization.

arXiv:1612.04327•Physical Review Letters•Feb 15, 2017•134 citations

Approaching Quantum-Limited Metrology with Imperfect Detectors by Using Weak-Value Amplification

Liang Xu, Zexuan Liu, Animesh Datta +4 more

Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.

arXiv:2005.03629•Physical Review Letters•Aug 17, 2020•98 citations

Effects of phase fluctuations on weak-value-based quantum metrology

Qing-Lin Wu, Ke-Xuan Chen, Zi-Rui Zhong

Weak measurement has ignited extensive research and discussions in the field of quantum metrology due to its sufficient potential in quantum measurement applications. Recent studies demonstrate that weak measurement protocols, when integrated with quantum resources, can achieve Heisenberg scaling while maintaining technical noise advantages. However, scenarios involving dephasing noise have not been addressed, as such noise induces rapid degradation of Heisenberg scaling to the standard quantum limit. Here, we incorporate phase fluctuations, a typical dephasing noise, into three Heisenberg-scaling systems. We find that postselection invariably reduces the robustness of quantum systems. Compared to coherent pointer states, squeezed coherent pointer states can exhibit superior resilience against phase fluctuations through appropriate squeezing-parameter optimization. In addition, in entanglement-assisted systems, we can optimize the postselected angle to compensate for Fisher information loss induced by the postselection process. Our findings reveal that weak measurement exhibits inherent limitations in dephasing noise metrology compared to conventional measurement.

Journal of the Optical Society of America B•Aug 1, 2025•0 citations

Spin-exchange relaxation-free magnetometer enhanced by biased weak measurement

Qian Cao, Shang Yu, Liang Xu +1 more

In quantum metrology researching, weak measurement has been widely applied in many aspects, providing weak-value amplification and noise suppressing ability. Recently, several modified schemes of weak measurement have been proposed, such as inverse, almost-balanced, and biased weak measurement. In this study, we enhance a spin-exchange relaxation-free (SERF) magnetometer using the biased weak measurement metrology technique. We establish and simulate a biased weak measurement (BWM)-enhanced SERF magnetometer model. By adjusting the pre-coupling process and analysing the Fisher information, higher sensitivity to magnetic fields is verified in this study. 0.003 fT can be achieved through adjusting pre-coupling process and extinction ratio, which is higher than the best sensitivity of SERF magnetometer in existence. Our work paves the way for embedding weak measurement techniques into atomic magnetometer sensors and greatly improving their sensitivity.

Results in Physics•Apr 2, 2024•4 citations
Weak measurement (WM) offers the advantage of amplifying small signals at the cost of postselecting a small portion of the probes. This so-called weak-value amplification effect makes it compare favorably with conventional techniques (without postselection) to overcome various technical noises. However, certain types of technical noise, such as jitter and pixelation, present insurmountable limitations for both WM and conventional techniques. In this work, we propose an advanced variant of WM that incorporates time-momentum correlation (TMC) into biased weak measurement (BWM). By employing the Fisher information metric, we theoretically show that TMC-BWM can overcome jitter and pixelation, and meanwhile extract significantly higher Fisher information. This dual advantage was experimentally validated in a magnetic-sensing application when applying severe jitter and pixelation, and it remains robust under natural conditions, achieving a 24.8-dB improvement in precision over the standard WM scheme. Moreover, merely classical resources are required to achieve this dual metrological advantage.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
Weak-value amplification (WVA) has recently become an important technique for parameter estimation, owing to its ability to enhance the signal-to-noise ratio by amplifying extremely small signals with proper postselection strategies. In this paper, we propose an adaptive WVA scheme to achieve the highest Fisher information when using an unbalanced pointer. Different from previous schemes, the adaptive WVA scheme is associated with a real-time update on the postselection states with the help of feedback information from the outcomes, and the ``extremely small'' condition set on the parameter of interest is relaxed. By applying this scheme to a time-delay measurement scenario, we show by numerical simulation that the precision achieved in our scheme is several times higher than the standard WVA scheme. Our result might open a path for improving the WVA technique in a more flexible and robust way.
Weak value amplification (WVA) is a technique by which one can magnify the apparent strength of a measurement signal. Some have claimed that WVA can outperform more conventional measurement schemes in parameter estimation. Nonetheless, a significant body of theoretical work has challenged this perspective, suggesting WVA to be fundamentally suboptimal. Optimal measurements may not be practical, however. Two practical considerations that have been conjectured to afford a benefit to WVA over conventional measurement are certain types of noise and detector saturation. Here, we report a theoretical study of the role of saturation and pixel noise in WVA-based measurement, in which we carry out a Bayesian analysis of the Fisher information available using a saturable, pixelated, digitized, and/or noisy detector. We draw two conclusions: first, that saturation alone does not confer an advantage to the WVA approach over conventional measurement, and second, that WVA can outperform conventional measurement when saturation is combined with intrinsic pixel noise and/or digitization.
Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.
Weak measurement has ignited extensive research and discussions in the field of quantum metrology due to its sufficient potential in quantum measurement applications. Recent studies demonstrate that weak measurement protocols, when integrated with quantum resources, can achieve Heisenberg scaling while maintaining technical noise advantages. However, scenarios involving dephasing noise have not been addressed, as such noise induces rapid degradation of Heisenberg scaling to the standard quantum limit. Here, we incorporate phase fluctuations, a typical dephasing noise, into three Heisenberg-scaling systems. We find that postselection invariably reduces the robustness of quantum systems. Compared to coherent pointer states, squeezed coherent pointer states can exhibit superior resilience against phase fluctuations through appropriate squeezing-parameter optimization. In addition, in entanglement-assisted systems, we can optimize the postselected angle to compensate for Fisher information loss induced by the postselection process. Our findings reveal that weak measurement exhibits inherent limitations in dephasing noise metrology compared to conventional measurement.
In quantum metrology researching, weak measurement has been widely applied in many aspects, providing weak-value amplification and noise suppressing ability. Recently, several modified schemes of weak measurement have been proposed, such as inverse, almost-balanced, and biased weak measurement. In this study, we enhance a spin-exchange relaxation-free (SERF) magnetometer using the biased weak measurement metrology technique. We establish and simulate a biased weak measurement (BWM)-enhanced SERF magnetometer model. By adjusting the pre-coupling process and analysing the Fisher information, higher sensitivity to magnetic fields is verified in this study. 0.003 fT can be achieved through adjusting pre-coupling process and extinction ratio, which is higher than the best sensitivity of SERF magnetometer in existence. Our work paves the way for embedding weak measurement techniques into atomic magnetometer sensors and greatly improving their sensitivity.