Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2201.13016

Fisher information analysis on post-selection involved quantum precision measurements using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

Published Jan 31, 2022• 0 citations
arXivHTMLPDF

Abstract

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful post-selection. %% In this work we show that, rather than the Gaussian meter state as typically considered, using the optical coherent state as a meter, the WVA measurement can definitely outperform the conventional measurement not involving the strategy of post-selection. %% We also show that the post-selection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in sharp contrast to the claim proved in the absence of post-selection. The post-selection strategy can also result in the precision of Heisenberg (or even "super-Heisenberg") scaling with the photon numbers, but without using any expensive quantum resources. %% The present work may stimulate further investigations for the potential of the post-selection strategy in quantum precision measurements.

DOI
10.48550/arxiv.2201.13016

Related papers

Fisher information analysis on weak-value-amplification metrology using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.

Physical Review A•Aug 30, 2022•20 citations

Enhanced weak-value amplification with Schrödinger cat-like states

Krishna Mishra, Gaurav Shukla, Devendra Mishra

Weak-value amplification (WVA) has emerged as an effective technique for detecting extremely small physical parameters by combining weak system–meter interactions with a carefully chosen post-selection strategy. In this paper, we explore how WVA performs when the meter is prepared in a Schrödinger cat-like state (SCS). Using the Fisher information (FI) as the primary figure of merit, we assess the attainable precision in estimating the interaction parameter. We compare the sensitivities of even coherent states (ECSs), odd coherent states (OCSs), and Yurke–Stoler states (YSSs) against coherent states (CS). We demonstrate that ECS and OCS as meters provide higher FI than the CS as a meter in some cases, depending on the measurement strategy. Also, ECS yields the largest conventional FI among the four meter states. Furthermore, we explore the impact of vacuum superposition with the meter on FI. We find that optimizing the vacuum coefficient enhances the FI in some conditions. This study shows that SCSs can be useful as meter states for improving precision in weak-measurement metrology.

Journal of the Optical Society of America B•Oct 8, 2026•0 citations

Quantum-coherence-free precision metrology by means of difference-signal amplification

Jialin Li, Yazhi Niu, Xinyi Wang +2 more

The novel weak-value-amplification (WVA) scheme of precision metrology is deeply rooted in the quantum nature of destructive interference between the pre- and post-selection states. And, an alternative version, termed as joint WVA (JWVA), which employs the difference-signal from the post-selection accepted and rejected results, has been found possible to achieve even better sensitivity (two orders of magnitude higher) under some technical limitations (e.g. misalignment errors). In this work, after erasing the quantum coherence, we analyze the difference-signal amplification (DSA) technique, which serves as a classical counterpart of the JWVA, and show that similar amplification effect can be achieved. We obtain a simple expression for the amplified signal, carry out characterization of precision, and point out the optimal working regime. We also discuss how to implement the post-selection of a classical mixed state. The proposed classical DSA technique holds similar technical advantages of the JWVA and may find interesting applications in practice.

arXiv:2212.13729•Scientific Reports•Mar 22, 2023•0 citations

Heisenberg-Limited Metrology via Weak-Value Amplification without Using Entangled Resources

Yosep Kim, Seung-Yeun Yoo, Yoon-Ho Kim

Weak-value amplification (WVA) provides a way for amplified detection of a tiny physical signal at the expense of a lower detection probability. Despite this trade-off, due to its robustness against certain types of noise, WVA has advantages over conventional measurements in precision metrology. Moreover, it has been shown that WVA-based metrology can reach the Heisenberg limit using entangled resources, but preparing macroscopic entangled resources remains challenging. Here, we demonstrate a novel WVA scheme based on iterative interactions, achieving the Heisenberg-limited precision scaling without resorting to entanglement. This indicates that the perceived advantages of the entanglement-assisted WVA are in fact due to iterative interactions between each particle of an entangled system and a meter, rather than coming from the entanglement itself. Our work opens a practical pathway for achieving the Heisenberg-limited WVA without using fragile and experimentally demanding entangled resources.

arXiv:2109.03762•Physical Review Letters•Jan 25, 2022•38 citations

Weak Value Amplification of a Post-Selected Single Photon

Matin Hallaji

Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.

•Jun 1, 2016•1 citation

Weak values considered harmful

Christopher Ferrie, Joshua Combes

We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

•Jul 15, 2013•1 citation
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful post-selection. %% In this work we show that, rather than the Gaussian meter state as typically considered, using the optical coherent state as a meter, the WVA measurement can definitely outperform the conventional measurement not involving the strategy of post-selection. %% We also show that the post-selection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in sharp contrast to the claim proved in the absence of post-selection. The post-selection strategy can also result in the precision of Heisenberg (or even "super-Heisenberg") scaling with the photon numbers, but without using any expensive quantum resources. %% The present work may stimulate further investigations for the potential of the post-selection strategy in quantum precision measurements.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.
Weak-value amplification (WVA) has emerged as an effective technique for detecting extremely small physical parameters by combining weak system–meter interactions with a carefully chosen post-selection strategy. In this paper, we explore how WVA performs when the meter is prepared in a Schrödinger cat-like state (SCS). Using the Fisher information (FI) as the primary figure of merit, we assess the attainable precision in estimating the interaction parameter. We compare the sensitivities of even coherent states (ECSs), odd coherent states (OCSs), and Yurke–Stoler states (YSSs) against coherent states (CS). We demonstrate that ECS and OCS as meters provide higher FI than the CS as a meter in some cases, depending on the measurement strategy. Also, ECS yields the largest conventional FI among the four meter states. Furthermore, we explore the impact of vacuum superposition with the meter on FI. We find that optimizing the vacuum coefficient enhances the FI in some conditions. This study shows that SCSs can be useful as meter states for improving precision in weak-measurement metrology.
The novel weak-value-amplification (WVA) scheme of precision metrology is deeply rooted in the quantum nature of destructive interference between the pre- and post-selection states. And, an alternative version, termed as joint WVA (JWVA), which employs the difference-signal from the post-selection accepted and rejected results, has been found possible to achieve even better sensitivity (two orders of magnitude higher) under some technical limitations (e.g. misalignment errors). In this work, after erasing the quantum coherence, we analyze the difference-signal amplification (DSA) technique, which serves as a classical counterpart of the JWVA, and show that similar amplification effect can be achieved. We obtain a simple expression for the amplified signal, carry out characterization of precision, and point out the optimal working regime. We also discuss how to implement the post-selection of a classical mixed state. The proposed classical DSA technique holds similar technical advantages of the JWVA and may find interesting applications in practice.
Weak-value amplification (WVA) provides a way for amplified detection of a tiny physical signal at the expense of a lower detection probability. Despite this trade-off, due to its robustness against certain types of noise, WVA has advantages over conventional measurements in precision metrology. Moreover, it has been shown that WVA-based metrology can reach the Heisenberg limit using entangled resources, but preparing macroscopic entangled resources remains challenging. Here, we demonstrate a novel WVA scheme based on iterative interactions, achieving the Heisenberg-limited precision scaling without resorting to entanglement. This indicates that the perceived advantages of the entanglement-assisted WVA are in fact due to iterative interactions between each particle of an entangled system and a meter, rather than coming from the entanglement itself. Our work opens a practical pathway for achieving the Heisenberg-limited WVA without using fragile and experimentally demanding entangled resources.
Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.
We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.