Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2212.13729 · Scientific Reports

Quantum-coherence-free precision metrology by means of difference-signal amplification

Jialin Li, Yazhi Niu, Xinyi Wang, Lupei Qin, Xin-Qi Li

Published Mar 22, 2023• 0 citations
arXivHTMLPDF

Abstract

The novel weak-value-amplification (WVA) scheme of precision metrology is deeply rooted in the quantum nature of destructive interference between the pre- and post-selection states. And, an alternative version, termed as joint WVA (JWVA), which employs the difference-signal from the post-selection accepted and rejected results, has been found possible to achieve even better sensitivity (two orders of magnitude higher) under some technical limitations (e.g. misalignment errors). In this work, after erasing the quantum coherence, we analyze the difference-signal amplification (DSA) technique, which serves as a classical counterpart of the JWVA, and show that similar amplification effect can be achieved. We obtain a simple expression for the amplified signal, carry out characterization of precision, and point out the optimal working regime. We also discuss how to implement the post-selection of a classical mixed state. The proposed classical DSA technique holds similar technical advantages of the JWVA and may find interesting applications in practice.

DOI
10.1038/s41598-023-31787-2

Related papers

Interference-based weak-value amplification effects in post-selected weak measurement

Yurong Liu, Zhaoxue Li, Yucheng Ye +2 more

Abstract Weak measurement (WM) based on post-selection is a useful tool for precision metrology due to the ability of amplifying weak physical effects. In this paper, we reveal the underlying mechanism of the amplification in the post-selected WM based on the weak-value amplification (WVA) and the almost balanced weak-values amplification (ABWVA) strategies. We find that the amplification stems from the interference between the local oscillator and signal components which are respectively associated with the initial system state and the state disturbance induced by the weak coupling. The magnitude of the amplification is proportional to the interference strength which is dominated by the post-selection and the coupling strength. Furthermore, our theory can perfectly explain the amplification limit in the WVA strategy and the anomalous amplification in the ABWVA strategy.

Laser Physics•Jul 29, 2021•1 citation

Impact of decoherence on the metrological advantage of weak-value amplification

Yu-Han 雨涵 Yan 严, Yan-Ping 艳萍 Tan 谭, Yan-Yan Lu +2 more

Abstract We present a theoretical investigation of weak-value amplification (WVA) under decoherence, quantifying its metrological capabilities through the quantum Fisher information (QFI). By modeling decoherence via Kraus operators acting before and after the weak measurement interaction, we derive exact expressions for the QFI governing parameter estimation of a weak coupling strength. These analytical results reveal the fundamental limitation imposed by decoherence on the QFI achievable via WVA. From these results, the optimal post-selection state that maximizes the QFI can be derived for different noise environments. Through paradigmatic examples, including amplitude damping and depolarizing channels, we demonstrate a key distinction: the optimal post-selection evolves with the noise strength in the amplitude damping channel, but is fixed in the depolarizing channel. This work provides both theoretical insights and practical guidance for optimizing metrological schemes based on WVA in realistic decoherent environments.

Chinese Physics B•Dec 9, 2025•0 citations

Fisher information analysis on post-selection involved quantum precision measurements using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful post-selection. %% In this work we show that, rather than the Gaussian meter state as typically considered, using the optical coherent state as a meter, the WVA measurement can definitely outperform the conventional measurement not involving the strategy of post-selection. %% We also show that the post-selection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in sharp contrast to the claim proved in the absence of post-selection. The post-selection strategy can also result in the precision of Heisenberg (or even "super-Heisenberg") scaling with the photon numbers, but without using any expensive quantum resources. %% The present work may stimulate further investigations for the potential of the post-selection strategy in quantum precision measurements.

arXiv:2201.13016•Jan 31, 2022•0 citations

Heisenberg-Limited Metrology via Weak-Value Amplification without Using Entangled Resources

Yosep Kim, Seung-Yeun Yoo, Yoon-Ho Kim

Weak-value amplification (WVA) provides a way for amplified detection of a tiny physical signal at the expense of a lower detection probability. Despite this trade-off, due to its robustness against certain types of noise, WVA has advantages over conventional measurements in precision metrology. Moreover, it has been shown that WVA-based metrology can reach the Heisenberg limit using entangled resources, but preparing macroscopic entangled resources remains challenging. Here, we demonstrate a novel WVA scheme based on iterative interactions, achieving the Heisenberg-limited precision scaling without resorting to entanglement. This indicates that the perceived advantages of the entanglement-assisted WVA are in fact due to iterative interactions between each particle of an entangled system and a meter, rather than coming from the entanglement itself. Our work opens a practical pathway for achieving the Heisenberg-limited WVA without using fragile and experimentally demanding entangled resources.

arXiv:2109.03762•Physical Review Letters•Jan 25, 2022•38 citations

Hamiltonian estimation based on adaptive weak value amplification

Chen Fang, Binke Xia, Jingzheng Huang +4 more

Abstract Hamiltonian estimation is a cardinal task in applications of quantum metrology, quantum computation, quantum simulation, etc. When the evolution time is short in order to suppress noise and enhance sensitivity, the measurement and postprocessing may incur high cost. In this paper, we propose an adaptive weak measurement scheme for Hamiltonian estimation, which adjusts the pre- and post-selection according to the difference of the mean shift between two orthogonal post-selected states. According to the angle of the post-selected state, the proposed scheme can change from weak value amplification (WVA) to joint weak measurement (JWM). A study of the quantum Fisher information shows that the JWM situation is always optimal. Meanwhile, the WVA approach loses a little information but it can inherit the WVA’s technical advantages, which are suitable for short evolution times. The widely applicable scope of the proposed scheme makes us believe that it offers a new path for the understanding of unknown Hamiltonians.

Journal of Physics B Atomic Molecular and Optical Physics•Feb 15, 2021•3 citations

Approaching Quantum-Limited Metrology with Imperfect Detectors by Using Weak-Value Amplification

Liang Xu, Zexuan Liu, Animesh Datta +4 more

Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.

arXiv:2005.03629•Physical Review Letters•Aug 17, 2020•97 citations
The novel weak-value-amplification (WVA) scheme of precision metrology is deeply rooted in the quantum nature of destructive interference between the pre- and post-selection states. And, an alternative version, termed as joint WVA (JWVA), which employs the difference-signal from the post-selection accepted and rejected results, has been found possible to achieve even better sensitivity (two orders of magnitude higher) under some technical limitations (e.g. misalignment errors). In this work, after erasing the quantum coherence, we analyze the difference-signal amplification (DSA) technique, which serves as a classical counterpart of the JWVA, and show that similar amplification effect can be achieved. We obtain a simple expression for the amplified signal, carry out characterization of precision, and point out the optimal working regime. We also discuss how to implement the post-selection of a classical mixed state. The proposed classical DSA technique holds similar technical advantages of the JWVA and may find interesting applications in practice.
Abstract Weak measurement (WM) based on post-selection is a useful tool for precision metrology due to the ability of amplifying weak physical effects. In this paper, we reveal the underlying mechanism of the amplification in the post-selected WM based on the weak-value amplification (WVA) and the almost balanced weak-values amplification (ABWVA) strategies. We find that the amplification stems from the interference between the local oscillator and signal components which are respectively associated with the initial system state and the state disturbance induced by the weak coupling. The magnitude of the amplification is proportional to the interference strength which is dominated by the post-selection and the coupling strength. Furthermore, our theory can perfectly explain the amplification limit in the WVA strategy and the anomalous amplification in the ABWVA strategy.
Abstract We present a theoretical investigation of weak-value amplification (WVA) under decoherence, quantifying its metrological capabilities through the quantum Fisher information (QFI). By modeling decoherence via Kraus operators acting before and after the weak measurement interaction, we derive exact expressions for the QFI governing parameter estimation of a weak coupling strength. These analytical results reveal the fundamental limitation imposed by decoherence on the QFI achievable via WVA. From these results, the optimal post-selection state that maximizes the QFI can be derived for different noise environments. Through paradigmatic examples, including amplitude damping and depolarizing channels, we demonstrate a key distinction: the optimal post-selection evolves with the noise strength in the amplitude damping channel, but is fixed in the depolarizing channel. This work provides both theoretical insights and practical guidance for optimizing metrological schemes based on WVA in realistic decoherent environments.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful post-selection. %% In this work we show that, rather than the Gaussian meter state as typically considered, using the optical coherent state as a meter, the WVA measurement can definitely outperform the conventional measurement not involving the strategy of post-selection. %% We also show that the post-selection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in sharp contrast to the claim proved in the absence of post-selection. The post-selection strategy can also result in the precision of Heisenberg (or even "super-Heisenberg") scaling with the photon numbers, but without using any expensive quantum resources. %% The present work may stimulate further investigations for the potential of the post-selection strategy in quantum precision measurements.
Weak-value amplification (WVA) provides a way for amplified detection of a tiny physical signal at the expense of a lower detection probability. Despite this trade-off, due to its robustness against certain types of noise, WVA has advantages over conventional measurements in precision metrology. Moreover, it has been shown that WVA-based metrology can reach the Heisenberg limit using entangled resources, but preparing macroscopic entangled resources remains challenging. Here, we demonstrate a novel WVA scheme based on iterative interactions, achieving the Heisenberg-limited precision scaling without resorting to entanglement. This indicates that the perceived advantages of the entanglement-assisted WVA are in fact due to iterative interactions between each particle of an entangled system and a meter, rather than coming from the entanglement itself. Our work opens a practical pathway for achieving the Heisenberg-limited WVA without using fragile and experimentally demanding entangled resources.
Abstract Hamiltonian estimation is a cardinal task in applications of quantum metrology, quantum computation, quantum simulation, etc. When the evolution time is short in order to suppress noise and enhance sensitivity, the measurement and postprocessing may incur high cost. In this paper, we propose an adaptive weak measurement scheme for Hamiltonian estimation, which adjusts the pre- and post-selection according to the difference of the mean shift between two orthogonal post-selected states. According to the angle of the post-selected state, the proposed scheme can change from weak value amplification (WVA) to joint weak measurement (JWM). A study of the quantum Fisher information shows that the JWM situation is always optimal. Meanwhile, the WVA approach loses a little information but it can inherit the WVA’s technical advantages, which are suitable for short evolution times. The widely applicable scope of the proposed scheme makes us believe that it offers a new path for the understanding of unknown Hamiltonians.
Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.