arXiv:1803.03024 · Physical Review A

Magnetic-field gradiometer based on ultracold collisions

Tomasz Wasak, Krzysztof Jachymski, Tommaso Calarco, Antonio Negretti

Published May 3, 2018• 5 citations
arXivHTMLPDF

Abstract

We present a detailed analysis of the usefulness of ultracold atomic collisions for sensing the strength of an external magnetic field as well as its spatial gradient. The core idea of the sensor, which we recently proposed in Jachymski et al. [Phys. Rev. Lett. 120, 013401 (2018)], is to probe the transmission of the atoms through a set of quasi-one-dimensional waveguides that contain an impurity. Magnetic-field-dependent interactions between the incoming atoms and the impurity naturally lead to narrow resonances that can act as sensitive field probes since they strongly affect the transmission. We illustrate our findings with concrete examples of experimental relevance, demonstrating that for large atom fluences $N$ a sensitivity of the order of 1 nT/$\sqrt{N}$ for the field strength and 100 nT/(mm $\sqrt{N}$) for the gradient can be reached with our scheme.

DOI
10.1103/physreva.97.052701

Related papers

Ultracold collisional magnetic field gradiometer

Tomasz Wasak, Krzysztof Jachymski, Tommaso Calarco +1 more

We present a detailed analysis of the usefulness of ultracold atomic collisions for sensing the strength of an external magnetic field as well as its spatial gradient. The core idea of the sensor, which we recently proposed in K. Jachymski \emph{et al.}, Phys. Rev. Lett. {\bf 120}, 013401 (2018), is to probe the transmission of the atoms through a set of quasi-one-dimensional waveguides that contain an impurity. Magnetic field-dependent interactions between the incoming atoms and the impurity naturally lead to narrow resonances that can act as sensitive field probes since they strongly affect the transmission. We illustrate our findings with concrete examples of experimental relevance, demonstrating that a sensitivity of the order of 1 nT for the field strength and $100\,\mathrm{nT}/\mathrm{mm}$ for the gradient can be reached using our scheme.

arXiv:1803.03024?context=physics.atom-ph•Mar 8, 2018•0 citations

Sensitivity of a collisional single-atom spin probe

Jens Nettersheim, Quentin Bouton, Daniel Adam +1 more

We study the sensitivity of a collisional single-atom probe for ultracold gases. Inelastic spin-exchange collisions map information about the gas temperature T or external magnetic field B onto the quantum spin-population of single-atom probes, and previous work showed enhanced sensitivity for short-time nonequilibrium spin dynamics [Phys. Rev. X 10, 011018 (2020)]. Here, we numerically investigate the steady-state sensitivity of such single-atom probes to various observables. We find that the probe shows distinct sensitivity maxima in the (B,T) parameter diagram, although the underlying spin-exchange rates scale monotonically with temperature and magnetic field. In parameter space, the probe generally has the largest sensitivity when sensing the energy ratio between thermal energy and Zeeman energy in an externally applied magnetic field, while the sensitivity to the absolute energy, i.e., the sum of kinetic and Zeeman energy, is low. We identify the parameters yielding sensitivity maxima for a given absolute energy, which we can relate to a direct comparison of the thermal Maxwell-Boltzmann distribution with the Zeeman-energy splitting. We compare our equilibrium results to nonequilibrium experimental results from a single-atom quantum probe, showing that the sensitivity maxima in parameter space qualitatively prevail also in the nonequilibrium dynamics, while a quantitative difference remains. Our work thereby offers a microscopic explanation for the properties and performance of this single-atom quantum probe, connecting thermodynamic properties to microscopic interaction mechanisms. Our results pave the way for optimization of quantum-probe applications in (B,T) parameter space beyond the previously shown boost by nonequilibrium dynamics.

arXiv:2203.13656•SciPost Physics Core•Feb 16, 2023•2 citations

A microfabricated optically-pumped magnetic gradiometer

D. Sheng, Abigail R. Perry, Sean Krzyzewski +3 more

We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.

arXiv:1701.03236•Applied Physics Letters•Jan 16, 2017•179 citations

Single-Atom Transistor as a Precise Magnetic Field Sensor

Krzysztof Jachymski, Tomasz Wasak, Zbigniew Idziaszek +3 more

Feshbach resonances, which allow for tuning the interactions of ultracold atoms with an external magnetic field, have been widely used to control the properties of quantum gases. We propose a scheme for using scattering resonances as a probe for external fields, showing that by carefully tuning the parameters it is possible to reach a 10^{-5} G (or nT) level of precision with a single pair of atoms. We show that, for our collisional setup, it is possible to saturate the quantum precision bound with a simple measurement protocol.

arXiv:1707.06018•Physical Review Letters•Jan 3, 2018•11 citations

Ultracold Atomic Magnetometry: Towards Quantum-Limited Sensing

Sula, Sindi

This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.

•Oct 28, 2025•0 citations

Precisely mapping the magnetic field gradient in vacuum with an atom interferometer

Min-Kang Zhou, Zhong-Kun Hu, Xiao‐Chun Duan +3 more

The magnetic field gradient has been measured with an atom interferometer using the magnetic sublevels of $^{87}\mathrm{Rb}$ atoms. The Doppler-insensitive measurement effectively eliminates the contribution from gravity and background vibration noise, and the differential measurement also can reject some systematic errors. A resolution of $300$ pT/mm has been demonstrated with a $90$-s integration time and a spatial resolution of $1.4$ mm. The gradiometer was then used to measure the magnetic field gradient in an ultrahigh-vacuum environment. The technique will also be very useful to subtract the systematic error arising from the magnetic field inhomogeneity in precision atom-interferometry experiments, such as gravity measurement.

Physical Review A•Dec 10, 2010•61 citations
We present a detailed analysis of the usefulness of ultracold atomic collisions for sensing the strength of an external magnetic field as well as its spatial gradient. The core idea of the sensor, which we recently proposed in Jachymski et al. [Phys. Rev. Lett. 120, 013401 (2018)], is to probe the transmission of the atoms through a set of quasi-one-dimensional waveguides that contain an impurity. Magnetic-field-dependent interactions between the incoming atoms and the impurity naturally lead to narrow resonances that can act as sensitive field probes since they strongly affect the transmission. We illustrate our findings with concrete examples of experimental relevance, demonstrating that for large atom fluences NNN a sensitivity of the order of 1 nT/N\sqrt{N}N​ for the field strength and 100 nT/(mm N\sqrt{N}N​) for the gradient can be reached with our scheme.
We present a detailed analysis of the usefulness of ultracold atomic collisions for sensing the strength of an external magnetic field as well as its spatial gradient. The core idea of the sensor, which we recently proposed in K. Jachymski \emph{et al.}, Phys. Rev. Lett. {\bf 120}, 013401 (2018), is to probe the transmission of the atoms through a set of quasi-one-dimensional waveguides that contain an impurity. Magnetic field-dependent interactions between the incoming atoms and the impurity naturally lead to narrow resonances that can act as sensitive field probes since they strongly affect the transmission. We illustrate our findings with concrete examples of experimental relevance, demonstrating that a sensitivity of the order of 1 nT for the field strength and 100 nT/mm100\,\mathrm{nT}/\mathrm{mm}100nT/mm for the gradient can be reached using our scheme.
We study the sensitivity of a collisional single-atom probe for ultracold gases. Inelastic spin-exchange collisions map information about the gas temperature T or external magnetic field B onto the quantum spin-population of single-atom probes, and previous work showed enhanced sensitivity for short-time nonequilibrium spin dynamics [Phys. Rev. X 10, 011018 (2020)]. Here, we numerically investigate the steady-state sensitivity of such single-atom probes to various observables. We find that the probe shows distinct sensitivity maxima in the (B,T) parameter diagram, although the underlying spin-exchange rates scale monotonically with temperature and magnetic field. In parameter space, the probe generally has the largest sensitivity when sensing the energy ratio between thermal energy and Zeeman energy in an externally applied magnetic field, while the sensitivity to the absolute energy, i.e., the sum of kinetic and Zeeman energy, is low. We identify the parameters yielding sensitivity maxima for a given absolute energy, which we can relate to a direct comparison of the thermal Maxwell-Boltzmann distribution with the Zeeman-energy splitting. We compare our equilibrium results to nonequilibrium experimental results from a single-atom quantum probe, showing that the sensitivity maxima in parameter space qualitatively prevail also in the nonequilibrium dynamics, while a quantitative difference remains. Our work thereby offers a microscopic explanation for the properties and performance of this single-atom quantum probe, connecting thermodynamic properties to microscopic interaction mechanisms. Our results pave the way for optimization of quantum-probe applications in (B,T) parameter space beyond the previously shown boost by nonequilibrium dynamics.
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.
Feshbach resonances, which allow for tuning the interactions of ultracold atoms with an external magnetic field, have been widely used to control the properties of quantum gases. We propose a scheme for using scattering resonances as a probe for external fields, showing that by carefully tuning the parameters it is possible to reach a 10^{-5} G (or nT) level of precision with a single pair of atoms. We show that, for our collisional setup, it is possible to saturate the quantum precision bound with a simple measurement protocol.
This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.
The magnetic field gradient has been measured with an atom interferometer using the magnetic sublevels of 87Rb^{87}\mathrm{Rb}87Rb atoms. The Doppler-insensitive measurement effectively eliminates the contribution from gravity and background vibration noise, and the differential measurement also can reject some systematic errors. A resolution of 300300300 pT/mm has been demonstrated with a 909090-s integration time and a spatial resolution of 1.41.41.4 mm. The gradiometer was then used to measure the magnetic field gradient in an ultrahigh-vacuum environment. The technique will also be very useful to subtract the systematic error arising from the magnetic field inhomogeneity in precision atom-interferometry experiments, such as gravity measurement.