Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1802.10379 · Superconductor Science and Technology

Tunable sub-gap radiation detection with superconducting resonators

O Dupré, A. D. Benoit, Martino Calvo, Andrea Catalano, J. Goupy, C. Hoarau, T. Klein, Kévin Le Calvez, Benjamin Sacépé, A. Monfardini, F. Lévy-Bertrand

Published Jan 20, 2017• 30 citations
arXivHTMLPDF

Abstract

Abstract We have fabricated planar amorphous indium oxide superconducting resonators ( T c ∼ 2.8 K) that are sensitive to frequency-selective radiation in the range of 7–10 GHz. Those values lay far below twice the superconducting gap that is worth about 200 GHz. The photon detection consists in a shift of the fundamental resonance frequency. We show that the detected frequency can be adjusted by modulating the total length of the superconducting resonator. We attribute those observations to the excitation of higher-order resonance modes. The coupling between the fundamental lumped and the higher order distributed resonance is due to the kinetic inductance nonlinearity with current. These devices, that we have called sub-gap kinetic inductance detectors, are to be distinguished from the standard kinetic inductance detectors in which quasi-particles are generated when incident light breaks down Cooper pairs.

DOI
10.1088/1361-6668/aa5b14

Related papers

Superconducting Microwave Resonator Arrays for Submillimeter/Far-infrared Imaging

Omid Noroozian

Superconducting microwave resonators have the potential to revolutionize submillimeter and far-infrared astronomy, and with it our understanding of the universe. The field of low-temperature detector technology has reached a point where extremely sensitive devices like transition-edge sensors are now capable of detecting radiation limited by the background noise of the universe. However, the size of these detector arrays are limited to only a few thousand pixels. This is because of the cost and complexity of fabricating large-scale arrays of these detectors that can reach up to 10 lithographic levels on chip, and the complicated SQUID-based multiplexing circuitry and wiring for readout of each detector. In order to make substantial progress, next- generation ground-based telescopes such as CCAT or future space telescopes require focal planes with large-scale detector arrays of 104–106 pixels. Arrays using microwave kinetic inductance detectors (MKID) are a potential solution. These arrays can be easily made with a single layer of superconducting metal film deposited on a silicon substrate and pattered using conventional optical lithography. Furthermore, MKIDs are inherently multiplexable in the frequency domain, allowing ∼ 103 detectors to be read out using a single coaxial transmission line and cryogenic amplifier, drastically reducing cost and complexity. An MKID uses the change in the microwave surface impedance of a superconducting thin-film microresonator to detect photons. Absorption of photons in the superconductor breaks Cooper pairs into quasiparticles, changing the complex surface impedance, which results in a perturbation of resonator frequency and quality factor. For excitation and readout, the resonator is weakly coupled to a transmission line. The complex amplitude of a microwave probe signal tuned on-resonance and transmitted on the feedline past the resonator is perturbed as photons are absorbed in the superconductor. The perturbation can be detected using a cryogenic amplifier and subsequent homodyne mixing at room temperature. In an array of MKIDs, all the resonators are coupled to a shared feedline and are tuned to slightly different frequencies. They can be read out simultaneously using a comb of frequencies generated and measured using digital techniques. This thesis documents an effort to demonstrate the basic operation of ∼ 256 pixel arrays of lumped-element MKIDs made from superconducting TiNx on silicon. The resonators are designed and simulated for optimum operation. Various properties of the resonators and arrays are measured and compared to theoretical expectations. A particularly exciting observation is the extremely high quality factors (∼ 3 × 107) of our TiNx resonators which is essential for ultra-high sensitivity. The arrays are tightly packed both in space and in frequency which is desirable for larger full-size arrays. However, this can cause a serious problem in terms of microwave crosstalk between neighboring pixels. We show that by properly designing the resonator geometry, crosstalk can be eliminated; this is supported by our measurement results. We also tackle the problem of excess frequency noise in MKIDs. Intrinsic noise in the form of an excess resonance frequency jitter exists in planar superconducting resonators that are made on dielectric substrates. We conclusively show that this noise is due to fluctuations of the resonator capacitance. In turn, the capacitance fluctuations are thought to be driven by two-level system (TLS) fluctuators in a thin layer on the surface of the device. With a modified resonator design we demonstrate with measurements that this noise can be substantially reduced. An optimized version of this resonator was designed for the multiwavelength submillimeter kinetic inductance camera (MUSIC) instrument for the Caltech Submillimeter Observatory.

•Jun 12, 2012•11 citations

Characterization of the kinetic inductance fraction of NbTiN MKIDs

Wei-Tao Lv, Qing Shi, Jing Li +2 more

Microwave Kinetic Inductance Detectors (MKIDs), with high sensitivity and relatively simple frequency multiplexing, are emerging as a kind of large-array detectors in the terahertz (THz) band. An MKID, like a superconducting resonator, is composed of a planar capacitor and inductor that are made from superconducting films. The energy gap of the superconducting film for the planar inductor (at least part of it) is lower than the energy of photons to be detected. The kinetic inductance of the superconducting film irradiated by the photons is increased, shifting the resonance frequency toward a lower frequency. The frequency shift is proportional to the kinetic inductance fraction, i.e., the ratio of the kinetic inductance to the total inductance of the planar superconducting inductor. In this paper, we thoroughly investigate the kinetic inductance fraction for lumped-element and antenna-coupled MKIDs, which are both made from NbTiN. The detailed simulation, calculation, and measurement results will be presented.

Infrared, Millimeter-Wave, and Terahertz Technologies•Oct 8, 2021•0 citations

Frequency-tunable high-Q superconducting resonators via wireless control of nonlinear kinetic inductance

Mingrui Xu, Xu Han, Wei Fu +2 more

Frequency-tunable microwave resonators are in great demand especially in hybrid systems where precise frequency alignment of resonances is required. Here, we present frequency-tunable high-Q superconducting resonators fabricated from thin niobium nitride and niobium titanium nitride films. The resonant frequency is tuned by applying a magnetic field perpendicular to the hole structures in the resonator's inductor wire, whose kinetic inductance is modified by wirelessly induced DC supercurrents. A continuous in situ frequency tuning of over 300 MHz is achieved for a 10 GHz resonator with a moderate magnetic field of 1.2 mT. The planar resonator design and the noncontact tuning scheme greatly ease the fabrication complexity and can be widely applied in many hybrid systems for coupling microwave modes with other forms of excitations such as optical photons, phonons, magnons, and spins.

Applied Physics Letters•May 13, 2019•61 citations

Subgap Kinetic Inductance Detector Sensitive to 85-GHz Radiation

F. Lévy-Bertrand, A. Benoı̂t, O. Bourrion +8 more

We have fabricated an array of subgap kinetic inductance detectors (SKIDs) made of granular aluminum (T$_{c}$∼2 K) sensitive in the 80–90 GHz frequency band and operating at 300 mK. We measure a noise equivalent power of 1.3×10$^{Zahl}$-16W/Hz$^{Zahl}$0.5 on average and 2.6×10$^{-17}$W/Hz$^{0.5}$ at best, for an illuminating power of 50 fW per pixel. Even though the circuit design of SKIDs is identical to that of the kinetic inductance detectors, the SKIDs operating principle is based on their sensitivity to subgap excitations. This detection scheme is advantageous because it avoids having to lower the operating temperature proportionally to the lowest detectable frequency. The SKIDs presented here are intrinsically selecting the 80–90 GHz frequency band, well below the superconducting spectral gap of the film, at approximately 180 GHz.

•Jan 1, 2021•9 citations

Flux-coupled tunable superconducting resonator

Juliang Li, Peter S. Barry, Tom Cecil +6 more

We present a design and implementation of a frequency-tunable superconducting resonator. The resonance frequency tunability is achieved by flux-coupling a superconducting LC loop to a current-biased feedline; the resulting screening current leads to a change of the kinetic inductance and shift in the resonance frequency. The thin-film aluminum resonator consists of an interdigitated capacitor and thin line inductors forming a closed superconducting loop. The magnetic flux from the nearby niobium current feedline induces Meissner shielding currents in the resonator loop leading to a change in the kinetic part of the total inductance of the resonator. We demonstrate continuous frequency tuning within 160 MHz around the resonant frequency of 2.7 GHz. We show that: (1) frequency up-conversion is achieved when a kilohertz ac modulation signal is superimposed onto the dc bias resulting in sidebands to the resonator tone; (2) three-wave mixing is attained by parametrically pumping the nonlinear kinetic inductance using a strong rf pump signal in the feedline. The simple architecture is amenable to large-array multiplexing and on-chip integration with other circuit components. The concept could be applied in flux magnetometers, up-converters, and parametric amplifiers operating above 4 K when alternative high-critical-temperature material with high kinetic inductance is used.

arXiv:2312.12755•Physical Review Applied•Jul 30, 2024•9 citations

Design and measurement of superconducting microwave kinetic inductance detectors

Florian Blauth

Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.

•Oct 1, 2019•0 citations
Abstract We have fabricated planar amorphous indium oxide superconducting resonators ( T c ∼ 2.8 K) that are sensitive to frequency-selective radiation in the range of 7–10 GHz. Those values lay far below twice the superconducting gap that is worth about 200 GHz. The photon detection consists in a shift of the fundamental resonance frequency. We show that the detected frequency can be adjusted by modulating the total length of the superconducting resonator. We attribute those observations to the excitation of higher-order resonance modes. The coupling between the fundamental lumped and the higher order distributed resonance is due to the kinetic inductance nonlinearity with current. These devices, that we have called sub-gap kinetic inductance detectors, are to be distinguished from the standard kinetic inductance detectors in which quasi-particles are generated when incident light breaks down Cooper pairs.
Superconducting microwave resonators have the potential to revolutionize submillimeter and far-infrared astronomy, and with it our understanding of the universe. The field of low-temperature detector technology has reached a point where extremely sensitive devices like transition-edge sensors are now capable of detecting radiation limited by the background noise of the universe. However, the size of these detector arrays are limited to only a few thousand pixels. This is because of the cost and complexity of fabricating large-scale arrays of these detectors that can reach up to 10 lithographic levels on chip, and the complicated SQUID-based multiplexing circuitry and wiring for readout of each detector. In order to make substantial progress, next- generation ground-based telescopes such as CCAT or future space telescopes require focal planes with large-scale detector arrays of 104–106 pixels. Arrays using microwave kinetic inductance detectors (MKID) are a potential solution. These arrays can be easily made with a single layer of superconducting metal film deposited on a silicon substrate and pattered using conventional optical lithography. Furthermore, MKIDs are inherently multiplexable in the frequency domain, allowing ∼ 103 detectors to be read out using a single coaxial transmission line and cryogenic amplifier, drastically reducing cost and complexity. An MKID uses the change in the microwave surface impedance of a superconducting thin-film microresonator to detect photons. Absorption of photons in the superconductor breaks Cooper pairs into quasiparticles, changing the complex surface impedance, which results in a perturbation of resonator frequency and quality factor. For excitation and readout, the resonator is weakly coupled to a transmission line. The complex amplitude of a microwave probe signal tuned on-resonance and transmitted on the feedline past the resonator is perturbed as photons are absorbed in the superconductor. The perturbation can be detected using a cryogenic amplifier and subsequent homodyne mixing at room temperature. In an array of MKIDs, all the resonators are coupled to a shared feedline and are tuned to slightly different frequencies. They can be read out simultaneously using a comb of frequencies generated and measured using digital techniques. This thesis documents an effort to demonstrate the basic operation of ∼ 256 pixel arrays of lumped-element MKIDs made from superconducting TiNx on silicon. The resonators are designed and simulated for optimum operation. Various properties of the resonators and arrays are measured and compared to theoretical expectations. A particularly exciting observation is the extremely high quality factors (∼ 3 × 107) of our TiNx resonators which is essential for ultra-high sensitivity. The arrays are tightly packed both in space and in frequency which is desirable for larger full-size arrays. However, this can cause a serious problem in terms of microwave crosstalk between neighboring pixels. We show that by properly designing the resonator geometry, crosstalk can be eliminated; this is supported by our measurement results. We also tackle the problem of excess frequency noise in MKIDs. Intrinsic noise in the form of an excess resonance frequency jitter exists in planar superconducting resonators that are made on dielectric substrates. We conclusively show that this noise is due to fluctuations of the resonator capacitance. In turn, the capacitance fluctuations are thought to be driven by two-level system (TLS) fluctuators in a thin layer on the surface of the device. With a modified resonator design we demonstrate with measurements that this noise can be substantially reduced. An optimized version of this resonator was designed for the multiwavelength submillimeter kinetic inductance camera (MUSIC) instrument for the Caltech Submillimeter Observatory.
Microwave Kinetic Inductance Detectors (MKIDs), with high sensitivity and relatively simple frequency multiplexing, are emerging as a kind of large-array detectors in the terahertz (THz) band. An MKID, like a superconducting resonator, is composed of a planar capacitor and inductor that are made from superconducting films. The energy gap of the superconducting film for the planar inductor (at least part of it) is lower than the energy of photons to be detected. The kinetic inductance of the superconducting film irradiated by the photons is increased, shifting the resonance frequency toward a lower frequency. The frequency shift is proportional to the kinetic inductance fraction, i.e., the ratio of the kinetic inductance to the total inductance of the planar superconducting inductor. In this paper, we thoroughly investigate the kinetic inductance fraction for lumped-element and antenna-coupled MKIDs, which are both made from NbTiN. The detailed simulation, calculation, and measurement results will be presented.
Frequency-tunable microwave resonators are in great demand especially in hybrid systems where precise frequency alignment of resonances is required. Here, we present frequency-tunable high-Q superconducting resonators fabricated from thin niobium nitride and niobium titanium nitride films. The resonant frequency is tuned by applying a magnetic field perpendicular to the hole structures in the resonator's inductor wire, whose kinetic inductance is modified by wirelessly induced DC supercurrents. A continuous in situ frequency tuning of over 300 MHz is achieved for a 10 GHz resonator with a moderate magnetic field of 1.2 mT. The planar resonator design and the noncontact tuning scheme greatly ease the fabrication complexity and can be widely applied in many hybrid systems for coupling microwave modes with other forms of excitations such as optical photons, phonons, magnons, and spins.
We have fabricated an array of subgap kinetic inductance detectors (SKIDs) made of granular aluminum (Tc_{c}c​∼2 K) sensitive in the 80–90 GHz frequency band and operating at 300 mK. We measure a noise equivalent power of 1.3×10Zahl^{Zahl}Zahl-16W/Hz$^{Zahl}0.5onaverageand2.6×100.5 on average and 2.6×100.5onaverageand2.6×10^{-17}W/HzW/HzW/Hz^{0.5}$ at best, for an illuminating power of 50 fW per pixel. Even though the circuit design of SKIDs is identical to that of the kinetic inductance detectors, the SKIDs operating principle is based on their sensitivity to subgap excitations. This detection scheme is advantageous because it avoids having to lower the operating temperature proportionally to the lowest detectable frequency. The SKIDs presented here are intrinsically selecting the 80–90 GHz frequency band, well below the superconducting spectral gap of the film, at approximately 180 GHz.
We present a design and implementation of a frequency-tunable superconducting resonator. The resonance frequency tunability is achieved by flux-coupling a superconducting LC loop to a current-biased feedline; the resulting screening current leads to a change of the kinetic inductance and shift in the resonance frequency. The thin-film aluminum resonator consists of an interdigitated capacitor and thin line inductors forming a closed superconducting loop. The magnetic flux from the nearby niobium current feedline induces Meissner shielding currents in the resonator loop leading to a change in the kinetic part of the total inductance of the resonator. We demonstrate continuous frequency tuning within 160 MHz around the resonant frequency of 2.7 GHz. We show that: (1) frequency up-conversion is achieved when a kilohertz ac modulation signal is superimposed onto the dc bias resulting in sidebands to the resonator tone; (2) three-wave mixing is attained by parametrically pumping the nonlinear kinetic inductance using a strong rf pump signal in the feedline. The simple architecture is amenable to large-array multiplexing and on-chip integration with other circuit components. The concept could be applied in flux magnetometers, up-converters, and parametric amplifiers operating above 4 K when alternative high-critical-temperature material with high kinetic inductance is used.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.