Abstract We address the performance of an interferometric setup in which a squeezed single photon interferes at a beam splitter with a coherent state. Our analysis in based on both the quantum Fisher information and the sensitivity when a Mach-Zehnder setup is considered and the difference photocurrent is detected at the output. We compare our results with those obtained feeding the interferometer with a squeezed vacuum (with the same squeezing parameter of the squeezed single photon) and a coherent state in order to have the same total number of photons circulating in the interferometer. We find that for fixed squeezing parameter and total number of photons there is a threshold of the coherent amplitude interfering with the squeezed single photon above which the squeezed single photons outperform the performance of squeezed vacuum (showing the highest quantum Fisher information). When the difference photocurrent measurement is considered, we can always find a threshold of the squeezing parameter (given the total number of photons and the coherent amplitude) above which squeezed single photons can be exploited to reach a better sensitivity with respect to the use of squeezed vacuum states also in the presence of non unit quantum efficiency.
Abstract We address the performance of an interferometric setup in which a squeezed single photon interferes at a beam splitter with a coherent state. Our analysis in based on both the quantum Fisher information and the sensitivity when a Mach-Zehnder setup is considered and the difference photocurrent is detected at the output. We compare our results with those obtained feeding the interferometer with a squeezed vacuum (with the same squeezing parameter of the squeezed single photon) and a coherent state in order to have the same total number of photons circulating in the interferometer. We find that for fixed squeezing parameter and total number of photons there is a threshold of the coherent amplitude interfering with the squeezed single photon above which the squeezed single photons outperform the performance of squeezed vacuum (showing the highest quantum Fisher information). When the difference photocurrent measurement is considered, we can always find a threshold of the squeezing parameter (given the total number of photons and the coherent amplitude) above which squeezed single photons can be exploited to reach a better sensitivity with respect to the use of squeezed vacuum states also in the presence of non unit quantum efficiency.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
Quantum metrology is to estimate accurately the value of an unknown parameter with the assistance of the quantum effects, in order to break through the standard quantum limit, even reach the Heisenberg limit. In this work, we study the performance of a general photon-added two-mode squeezed vacuum state that is taken as a detection state of a Mach-Zehnder interferometer. Based on quantum Fisher information, within the constraint on the total mean photon number, symmetric and asymmetric photon addition cannot improve the ultimate phase sensitivity. However, for a given initial squeezing parameter, on this occasion, the symmetric and asymmetric photon addition can improve the ultimate phase sensitivity. Compared with the asymmetric photon-added two-mode squeezed vacuum state, the symmetric one can well improve the ultimate phase sensitivity. This may be because it is always better to implement the symmetric photon addition rather than the asymmetric one in order to increase the mean photon number of the resulting state. On the other hand, via parity detection, the symmetric and asymmetric photon-added two-mode squeezed vacuum state can indeed improve the phase sensitivity of a Mach-Zehnder interferometer for a given initial squeezing parameter. Based on the parity detection, within a constraint on the mean photon number, although the two-mode squeezed vacuum state can give the better phase sensitivity at the optimal phase shift (φ = 0), the phase sensitivity offered by the symmetric and asymmetric photon-added two-mode squeezed vacuum states are both more stable around φ = 0 than by the two-mode squeezed vacuum state. In addition, we show that for the symmetric photon-added two-mode squeezed vacuum state, parity detection is an optimal detection only when the optimal phase shift approaches to zero. When the phase shift slightly deviates from zero, the parity detection is not an optimal detection scheme. Finally, for all values of the phase shift, our results also clearly show that the parity detection is not an optimal detection scheme for the asymmetric photon-added two-mode squeezed vacuum state serving as an interferometer state.
ABSTRACT Photon addition operations applied to squeezed states have been shown to significantly enhance phase sensitivity. In this work, we extend this approach by applying photon addition not only to coherent states but also within a Mach–Zehnder interferometer, using coherent and squeezed vacuum states as input. Both intensity‐difference and homodyne detection are used to evaluate photon addition schemes, and their phase sensitivities are compared under ideal and lossy conditions. We also analyze the quantum Fisher information of these two schemes. Results show that both schemes improve phase sensitivity, quantum Fisher information, and robustness against losses. In particular, photon addition within the interferometer performs better. Homodyne detection outperforms intensity difference detection under photon losses. Notably, the two schemes exhibit distinct parameter dependencies, rendering them suitable for different operational scenarios. When the squeezing parameter is small, photon addition employed at the coherent input with intensity difference detection can approach the Heisenberg limit in ideal conditions and can exceed the standard quantum limit in high‐loss conditions. The proposed scheme represents a valuable method for quantum precision measurements. PACS : 03.67.‐a, 05.30.‐d, 42.50,Dv, 03.65.Wj
We study multiphoton quantum-interference effects at a beam splitter and its connection to the prospect of attaining interferometric phase-shift measurements with noise levels below the standard quantum limit. Specifically, we consider the mixing of the most classical states of light coherent states with the most nonclassical states of light number states at a 50 : 50 beam splitter. Multiphoton quantum-interference effects from mixing photon-number states of small photon numbers with coherent states of arbitrary amplitudes are dramatic even at the level of a single photon. For input vacuum and coherent states, the joint photon-number distribution after the beam splitter is unimodal, a product of Poisson distributions for each of the output modes but with the input of a single photon, the original distribution is symmetrically bifurcated into a bimodal distribution. With a two-photon-number state mixed with a coherent state, a trimodal distribution is obtained, etc. The obtained distributions are shown to be structured so as to be conducive for approaching Heisenberg-limited sensitivities in photon-number parity-based interferometry. We show that mixing a coherent state with even a single photon results in a significant reduction in noise over that of the shot-noise limit. Finally, based on the results of mixing coherent light with single photons, we consider the mixing coherent light with the squeezed vacuum and the squeezed one-photon states and find the latter yields higher sensitivity in phase-shift measurements for the same squeeze parameter owing to the absence of the vacuum state.
An optical interferometer seeded by coherent and squeezed vacuum states seems to be the most promising platform for gravitational wave detection. Prior studies regarding this estimation protocol focus on the scenario in which the transmittances of two beam splitters are 21. In this paper, with respect to the same inputs, we analyze the phase sensitivity of an unbalanced Mach-Zehnder interferometer (MZI) followed by balanced homodyne measurement. We give the optimal transmittance and demonstrate the advantage of our scheme over a balanced MZI scheme. Additionally, when the average photon number of the coherent state is dominant, the phase sensitivity of our scheme can nearly saturate the single-parameter quantum Cram\'er-Rao bound. Our results may contribute to the development of practical quantum sensing.
Abstract In this work we address the optimization of two important quantum states in terms of interferometric phase sensitivity, given a constraint on the total average number of input photons, N ¯ We use the quantum Fisher information (QFI) as our main tool. We employ both the single- and two-parameter QFI in order to address detection schemes having, and respectively, not having access to an external phase reference. The first quantum state we consider is the coherent plus squeezed vacuum input and find the optimum coherent fraction that maximizes both the single- and two-parameter QFI. We also discuss detection schemes able to perform almost optimally. Finally, we consider the double squeezed vacuum input and determine the squeezed fraction between the inputs that maximizes the QFI. Similar to the previous input state, we also provide detection schemes able to perform optimally.