Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Multiphoton quantum interference at a beam splitter and the approach to Heisenberg-limited interferometry

Richard J. Birrittella, Jihane Mimih, Christopher C. Gerry

Published Dec 21, 2012• 55 citations
Publisher

Abstract

We study multiphoton quantum-interference effects at a beam splitter and its connection to the prospect of attaining interferometric phase-shift measurements with noise levels below the standard quantum limit. Specifically, we consider the mixing of the most classical states of light coherent states with the most nonclassical states of light number states at a 50 : 50 beam splitter. Multiphoton quantum-interference effects from mixing photon-number states of small photon numbers with coherent states of arbitrary amplitudes are dramatic even at the level of a single photon. For input vacuum and coherent states, the joint photon-number distribution after the beam splitter is unimodal, a product of Poisson distributions for each of the output modes but with the input of a single photon, the original distribution is symmetrically bifurcated into a bimodal distribution. With a two-photon-number state mixed with a coherent state, a trimodal distribution is obtained, etc. The obtained distributions are shown to be structured so as to be conducive for approaching Heisenberg-limited sensitivities in photon-number parity-based interferometry. We show that mixing a coherent state with even a single photon results in a significant reduction in noise over that of the shot-noise limit. Finally, based on the results of mixing coherent light with single photons, we consider the mixing coherent light with the squeezed vacuum and the squeezed one-photon states and find the latter yields higher sensitivity in phase-shift measurements for the same squeeze parameter owing to the absence of the vacuum state.

DOI
10.1103/physreva.86.063828

Related papers

Quantum optical interferometry via the mixing of coherent and photon-subtracted squeezed vacuum states of light

Richard J. Birrittella, Christopher C. Gerry

Hofmann and Ono [Phys. Rev. A76, 031806, (2007)] showed that the mixing of coherent light and single-mode squeezed light at a beam splitter gives good approximation results in a superposition of path-entangled photon number states (so-called N00N states), which can be used for phase-shift measurements by coincident detections at the output of an interferometer. They showed that N00N states for arbitrary photon number N could be produced by this procedure. Afek et al. [Science328, 879 (2010)] have implemented the Hofmann–Ono proposal in the laboratory. In this paper, we show that, for a given coherent state amplitude and a given squeezing parameter, the mixing of coherent states and photon-subtracted squeezed vacuum states at the first beam splitter of an interferometer leads to improved phase-shift measurement sensitivity when using the photon-number detection technique on one of the output beams of the device. We also show that the phase-shift measurements will also be super-resolved to a greater degree than is possible by mixing coherent and squeezed vacuum light of the same field parameters.

Journal of the Optical Society of America B•Feb 26, 2014•46 citations

Coherently stimulated parametric down-conversion, phase effects, and quantum-optical interferometry

Richard J. Birrittella, Anna Gura, Christopher C. Gerry

We re-examine the properties of the states produced by nondegenerate coherently stimulated parametric down-conversion wherein the signal and idler modes are seeded with coherent states of light and where the nonlinear crystal is driven by a strong classical field as described by the parametric approximation. The states produced are the two-mode squeezed coherent states defined with a specific ordering of operators, namely, the displacement operators of the two modes acting on the double vacuum state followed by the action of the two-mode squeeze operator representing the down-conversion process. Though mathematically equivalent to the reverse ordering of operators, but with different displacement parameters, the ordering we consider is closely related to what could most easily be implemented in the laboratory. The statistical properties of the state are studied with an emphasis on how they, and its average photon number, are affected by the various controllable phases, namely, those of the classical pump field of the two input coherent states. We then consider the multiphoton interference effects that arise if the two beams are overlapped on a 50:50 beam splitter, investigating the role of the phases in controlling the statistical properties of the output states. Finally, we study the prospects for the application of the states to quantum-optical interferometry to obtain sensitivities in phase-shift measurements beyond the standard quantum limit.

Physical Review A•May 5, 2015•14 citations

Phase estimation with squeezed single photons

Stefano Olivares, Maria Popovic, Matteo G. A. Paris

Abstract We address the performance of an interferometric setup in which a squeezed single photon interferes at a beam splitter with a coherent state. Our analysis in based on both the quantum Fisher information and the sensitivity when a Mach-Zehnder setup is considered and the difference photocurrent is detected at the output. We compare our results with those obtained feeding the interferometer with a squeezed vacuum (with the same squeezing parameter of the squeezed single photon) and a coherent state in order to have the same total number of photons circulating in the interferometer. We find that for fixed squeezing parameter and total number of photons there is a threshold of the coherent amplitude interfering with the squeezed single photon above which the squeezed single photons outperform the performance of squeezed vacuum (showing the highest quantum Fisher information). When the difference photocurrent measurement is considered, we can always find a threshold of the squeezing parameter (given the total number of photons and the coherent amplitude) above which squeezed single photons can be exploited to reach a better sensitivity with respect to the use of squeezed vacuum states also in the presence of non unit quantum efficiency.

arXiv:1802.02922•Quantum Measurements and Quantum Metrology•Jan 1, 2016•9 citations

Interference of macroscopic beams on a beam splitter: phase uncertainty converted into photon-number uncertainty

Kirill Yu. Spasibko, F Töppel, T Sh Iskhakov +3 more

Squeezed-vacuum twin beams, commonly generated through parametric down-conversion, are known to have perfect photon-number correlations. According to the Heisenberg principle, this is accompanied by a huge uncertainty in their relative phase. By overlapping bright twin beams on a beam splitter, we convert phase fluctuations into photon-number fluctuations and observe this uncertainty as a typical 'U-shape' of the output photon-number distribution. This effect, although reported for atomic ensembles and giving hope for phase super-resolution, has never been observed for light beams. The shape of the normalized photon-number difference distribution is similar to the one that would be observed for high-order Fock states. It can be also mimicked by classical beams with artificially mixed phase, but without any perspective for phase super-resolution. The probability distribution at the beam splitter output can be used for filtering macroscopic superpositions at the input.

arXiv:1309.2265•New Journal of Physics•Jan 17, 2014•14 citations

Photon-subtracted two-mode squeezed vacuum states and applications to quantum optical interferometry

Raul Carranza, Christopher C. Gerry

We study the application of photon-subtracted two-mode squeezed vacuum states (TMSVS), where identical photon numbers are subtracted from each beam, to the problem of quantum optical interferometry with the photon-number parity measurements scheme. Previously, Anisimov et al. [Phys. Rev. Lett.104, 103602 (2010)] have studied the prospect of using the TMSVS for parity measurements based interferometry. However, the joint photon number distribution of this state before beam splitting is thermal-like in each mode, meaning that its statistics are super-Poissonian and that the most probable state of the field is the double vacuum and that the average photon number is low. Furthermore, with these states the sensitivity of the phase-shift measurement is extremely sensitive to the size of the phase shift to be measured for large average photon numbers. The simultaneous subtraction of 1, 2, or 3 photons from each mode has the effects of increasing the average photon numbers of each mode and rendering the statistics nearly Poissonian and in some cases sub-Poissonian. We show that phase uncertainties for such states are less sensitive to the phase shift itself at large average photon numbers. We also show that the photon-subtracted TMSVS also lead to increased resolution.

Journal of the Optical Society of America B•Aug 30, 2012•108 citations

Phase-measurement sensitivity beyond the standard quantum limit in an interferometer consisting of a parametric amplifier and a beam splitter

Jia Kong, Z. Y. Ou, Weiping Zhang

We analyze a nonconventional interferometer that is formed with a parametric amplifier and a beam splitter for beam splitting and recombination. Because the outputs from a parametric amplifier are entangled and their quantum noise is correlated, the employment of the beam splitter will superimpose the two quantum fields and the destructive interference will lead to the subtraction of the quantum noise and to noise reduction in the output of the interferometer and hence an improvement of the signal-to-noise ratio (SNR) beyond the standard quantum limit or the shot noise limit. Furthermore, the injection of a squeezed state into the idler port of the parametric amplifier will lead to further improvement of the SNR. We will discuss the possibility of reaching the Heisenberg limit in such an interferometer. We find that the injection of a coherent state will degrade the performance in reaching the Heisenberg limit, whereas a squeezed state injection can improve it by a factor of 2 at best.

Physical Review A•Feb 20, 2013•44 citations
We study multiphoton quantum-interference effects at a beam splitter and its connection to the prospect of attaining interferometric phase-shift measurements with noise levels below the standard quantum limit. Specifically, we consider the mixing of the most classical states of light coherent states with the most nonclassical states of light number states at a 50 : 50 beam splitter. Multiphoton quantum-interference effects from mixing photon-number states of small photon numbers with coherent states of arbitrary amplitudes are dramatic even at the level of a single photon. For input vacuum and coherent states, the joint photon-number distribution after the beam splitter is unimodal, a product of Poisson distributions for each of the output modes but with the input of a single photon, the original distribution is symmetrically bifurcated into a bimodal distribution. With a two-photon-number state mixed with a coherent state, a trimodal distribution is obtained, etc. The obtained distributions are shown to be structured so as to be conducive for approaching Heisenberg-limited sensitivities in photon-number parity-based interferometry. We show that mixing a coherent state with even a single photon results in a significant reduction in noise over that of the shot-noise limit. Finally, based on the results of mixing coherent light with single photons, we consider the mixing coherent light with the squeezed vacuum and the squeezed one-photon states and find the latter yields higher sensitivity in phase-shift measurements for the same squeeze parameter owing to the absence of the vacuum state.
Hofmann and Ono [Phys. Rev. A76, 031806, (2007)] showed that the mixing of coherent light and single-mode squeezed light at a beam splitter gives good approximation results in a superposition of path-entangled photon number states (so-called N00N states), which can be used for phase-shift measurements by coincident detections at the output of an interferometer. They showed that N00N states for arbitrary photon number N could be produced by this procedure. Afek et al. [Science328, 879 (2010)] have implemented the Hofmann–Ono proposal in the laboratory. In this paper, we show that, for a given coherent state amplitude and a given squeezing parameter, the mixing of coherent states and photon-subtracted squeezed vacuum states at the first beam splitter of an interferometer leads to improved phase-shift measurement sensitivity when using the photon-number detection technique on one of the output beams of the device. We also show that the phase-shift measurements will also be super-resolved to a greater degree than is possible by mixing coherent and squeezed vacuum light of the same field parameters.
We re-examine the properties of the states produced by nondegenerate coherently stimulated parametric down-conversion wherein the signal and idler modes are seeded with coherent states of light and where the nonlinear crystal is driven by a strong classical field as described by the parametric approximation. The states produced are the two-mode squeezed coherent states defined with a specific ordering of operators, namely, the displacement operators of the two modes acting on the double vacuum state followed by the action of the two-mode squeeze operator representing the down-conversion process. Though mathematically equivalent to the reverse ordering of operators, but with different displacement parameters, the ordering we consider is closely related to what could most easily be implemented in the laboratory. The statistical properties of the state are studied with an emphasis on how they, and its average photon number, are affected by the various controllable phases, namely, those of the classical pump field of the two input coherent states. We then consider the multiphoton interference effects that arise if the two beams are overlapped on a 50:50 beam splitter, investigating the role of the phases in controlling the statistical properties of the output states. Finally, we study the prospects for the application of the states to quantum-optical interferometry to obtain sensitivities in phase-shift measurements beyond the standard quantum limit.
Abstract We address the performance of an interferometric setup in which a squeezed single photon interferes at a beam splitter with a coherent state. Our analysis in based on both the quantum Fisher information and the sensitivity when a Mach-Zehnder setup is considered and the difference photocurrent is detected at the output. We compare our results with those obtained feeding the interferometer with a squeezed vacuum (with the same squeezing parameter of the squeezed single photon) and a coherent state in order to have the same total number of photons circulating in the interferometer. We find that for fixed squeezing parameter and total number of photons there is a threshold of the coherent amplitude interfering with the squeezed single photon above which the squeezed single photons outperform the performance of squeezed vacuum (showing the highest quantum Fisher information). When the difference photocurrent measurement is considered, we can always find a threshold of the squeezing parameter (given the total number of photons and the coherent amplitude) above which squeezed single photons can be exploited to reach a better sensitivity with respect to the use of squeezed vacuum states also in the presence of non unit quantum efficiency.
Squeezed-vacuum twin beams, commonly generated through parametric down-conversion, are known to have perfect photon-number correlations. According to the Heisenberg principle, this is accompanied by a huge uncertainty in their relative phase. By overlapping bright twin beams on a beam splitter, we convert phase fluctuations into photon-number fluctuations and observe this uncertainty as a typical 'U-shape' of the output photon-number distribution. This effect, although reported for atomic ensembles and giving hope for phase super-resolution, has never been observed for light beams. The shape of the normalized photon-number difference distribution is similar to the one that would be observed for high-order Fock states. It can be also mimicked by classical beams with artificially mixed phase, but without any perspective for phase super-resolution. The probability distribution at the beam splitter output can be used for filtering macroscopic superpositions at the input.
We study the application of photon-subtracted two-mode squeezed vacuum states (TMSVS), where identical photon numbers are subtracted from each beam, to the problem of quantum optical interferometry with the photon-number parity measurements scheme. Previously, Anisimov et al. [Phys. Rev. Lett.104, 103602 (2010)] have studied the prospect of using the TMSVS for parity measurements based interferometry. However, the joint photon number distribution of this state before beam splitting is thermal-like in each mode, meaning that its statistics are super-Poissonian and that the most probable state of the field is the double vacuum and that the average photon number is low. Furthermore, with these states the sensitivity of the phase-shift measurement is extremely sensitive to the size of the phase shift to be measured for large average photon numbers. The simultaneous subtraction of 1, 2, or 3 photons from each mode has the effects of increasing the average photon numbers of each mode and rendering the statistics nearly Poissonian and in some cases sub-Poissonian. We show that phase uncertainties for such states are less sensitive to the phase shift itself at large average photon numbers. We also show that the photon-subtracted TMSVS also lead to increased resolution.
We analyze a nonconventional interferometer that is formed with a parametric amplifier and a beam splitter for beam splitting and recombination. Because the outputs from a parametric amplifier are entangled and their quantum noise is correlated, the employment of the beam splitter will superimpose the two quantum fields and the destructive interference will lead to the subtraction of the quantum noise and to noise reduction in the output of the interferometer and hence an improvement of the signal-to-noise ratio (SNR) beyond the standard quantum limit or the shot noise limit. Furthermore, the injection of a squeezed state into the idler port of the parametric amplifier will lead to further improvement of the SNR. We will discuss the possibility of reaching the Heisenberg limit in such an interferometer. We find that the injection of a coherent state will degrade the performance in reaching the Heisenberg limit, whereas a squeezed state injection can improve it by a factor of 2 at best.