Physical Review A

Unbalanced beam splitters enabling enhanced phase sensitivity of a Mach-Zehnder interferometer using coherent and squeezed vacuum states

Jiandong Zhang, Shuai Wang

Published Apr 6, 2023• 14 citations
Publisher

Abstract

An optical interferometer seeded by coherent and squeezed vacuum states seems to be the most promising platform for gravitational wave detection. Prior studies regarding this estimation protocol focus on the scenario in which the transmittances of two beam splitters are $\frac{1}{2}$. In this paper, with respect to the same inputs, we analyze the phase sensitivity of an unbalanced Mach-Zehnder interferometer (MZI) followed by balanced homodyne measurement. We give the optimal transmittance and demonstrate the advantage of our scheme over a balanced MZI scheme. Additionally, when the average photon number of the coherent state is dominant, the phase sensitivity of our scheme can nearly saturate the single-parameter quantum Cram\'er-Rao bound. Our results may contribute to the development of practical quantum sensing.

DOI
10.1103/physreva.107.043704

Related papers

Enhancing phase sensitivity in a Mach-Zehnder interferometer with various detection schemes using SU(1,1) coherent states

Nour-Eddine Abouelkhir, Abdallah Slaoui, El Hassan Saidi +2 more

Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.

arXiv:2406.08007•Journal of the Optical Society of America B•Dec 23, 2024•14 citations

Nonlinear phase estimation enhanced by an actively correlated Mach-Zehnder interferometer

Gao-Feng Jiao, Keye Zhang, L. Q. Chen +2 more

A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.

arXiv:2009.08059•Physical Review A•Sep 21, 2020•27 citations

Phase sensitivity for an unbalanced interferometer without input phase-matching restrictions

Anca Preda, Stefan Ataman

The Cram\'er-Rao bound and the quantum Fisher information have been tools used extensively for interferometric phase sensitivity. Most scenarios considering a Mach-Zehnder interferometer with two input sources focused on the phase-matched case, when the Fisher information is maximal. Under this constraint, the best sensitivity is achieved for a balanced (50/50) input beam splitter. In this paper, we take a different approach: we allow the beam splitter transmission coefficient as well as the input phase mismatch to be variable parameters. We then search for a pair of these parameters that maximizes the Fisher information. We find that for the double coherent input the maximum Fisher information can always be reached in the unbalanced case for a carefully chosen input phase mismatch. For the coherent plus squeezed vacuum case we find that under certain circumstances a threshold phase mismatch exists, beyond which the optimum Fisher information is found for the degenerate case. For the squeezed-coherent plus squeezed vacuum case we find that the optimum actually occurs when the squeezing angles of the two inputs are in antiphase.

arXiv:1905.02557•Physical Review A•May 7, 2019•18 citations

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•13 citations

Enhanced phase sensitivity of the Mach-Zehnder-type phase-shifting interferometry with single-intensity and difference-intensity detection

Huanrong He, Yu Zhang

Phase-shifting interferometry (PSI) promises excellent performance for quantitative phase measurement. However, the PSI is commonly realized by utilizing the Mach-Zehnder interferometer (MZI) fed with classical resources, and hence its phase sensitivity is hindered by the photon shot noise. In this paper, we propose to introduce specific phase-shifting algorithms into the well-established quantum-enhanced MZI, seeded by coherent and squeezed vacuum states and followed by single-mode intensity detection and difference intensity detection, to achieve quantitative phase measurement with sensitivity beyond that achieved by the corresponding Mach-Zehnder-type PSI with classical input. We show that when the average photon number of the coherent state is dominant, the optimal phase sensitivity of the Mach-Zehnder-type PSI with coherent plus squeezed vacuum input is better than the phase sensitivity of the Mach-Zehnder-type PSI with single coherent input under the same phase-sensing intensity condition in both of detection setups. We also show that for the typical MZI seeded with a high-power coherent state and a finitely squeezed vacuum state, the combination of intensity detection and phase-shifting algorithm can still improve the sensitivity of quantitative phase measurement. Furthermore, we derive the phase sensitivity of the fixed MZI as well as the quantum Cramér-Rao bound for two detection schemes. Finally, we explore the impacts of photon losses on the phase sensitivity enhancements of the Mach-Zehnder-type PSI and the fixed MZI in the high-intensity regime for each detection setup. The robustness to losses is compared between the Mach-Zehnder-type PSI and the fixed MZI. Our results may be helpful to promote the exploration of quantum-enhanced quantitative phase sensing.

Optics Express•Jul 17, 2026•0 citations

The impact of parametric amplifiers on the phase sensitivity for an unbalanced interferometer

Ilinca Butu, Karunesh Kumar Mishra, Stefan Ataman

This paper provides a theoretical analysis of a Mach–Zehnder interferometer (MZI) enhanced by optical parametric amplifiers (OPA) placed inside its arms and fed by a coherent input source. Contrary to most cases found in literature, we perform a wider analysis by considering the MZI unbalanced and two internal phase shifts. We discuss the theoretical best-case phase sensitivity of this setup via the quantum Cramér–Rao bound (QCRB) and we consider scenarios having – or not – access to an external phase reference. We also assess the realistic performance of the OPA-enhanced MZI by employing a balanced homodyne detection (asymmetric and symmetric phase shifts) scheme and a difference-intensity detection scheme. We are thus able to find the optimum beam splitter (BS) transmissivity (transmission coefficient) of the first BS via the quantum Fisher information (QFI), while for the second one, we need to take the detection scheme into account. We are able to find these optimal values for all considered scenarios and thus assess the best-case phase sensitivity provided by this setup.

International Journal of Quantum Information•Feb 4, 2026•1 citation
An optical interferometer seeded by coherent and squeezed vacuum states seems to be the most promising platform for gravitational wave detection. Prior studies regarding this estimation protocol focus on the scenario in which the transmittances of two beam splitters are 12\frac{1}{2}21​. In this paper, with respect to the same inputs, we analyze the phase sensitivity of an unbalanced Mach-Zehnder interferometer (MZI) followed by balanced homodyne measurement. We give the optimal transmittance and demonstrate the advantage of our scheme over a balanced MZI scheme. Additionally, when the average photon number of the coherent state is dominant, the phase sensitivity of our scheme can nearly saturate the single-parameter quantum Cram'er-Rao bound. Our results may contribute to the development of practical quantum sensing.
Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.
A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.
The Cram\'er-Rao bound and the quantum Fisher information have been tools used extensively for interferometric phase sensitivity. Most scenarios considering a Mach-Zehnder interferometer with two input sources focused on the phase-matched case, when the Fisher information is maximal. Under this constraint, the best sensitivity is achieved for a balanced (50/50) input beam splitter. In this paper, we take a different approach: we allow the beam splitter transmission coefficient as well as the input phase mismatch to be variable parameters. We then search for a pair of these parameters that maximizes the Fisher information. We find that for the double coherent input the maximum Fisher information can always be reached in the unbalanced case for a carefully chosen input phase mismatch. For the coherent plus squeezed vacuum case we find that under certain circumstances a threshold phase mismatch exists, beyond which the optimum Fisher information is found for the degenerate case. For the squeezed-coherent plus squeezed vacuum case we find that the optimum actually occurs when the squeezing angles of the two inputs are in antiphase.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
Phase-shifting interferometry (PSI) promises excellent performance for quantitative phase measurement. However, the PSI is commonly realized by utilizing the Mach-Zehnder interferometer (MZI) fed with classical resources, and hence its phase sensitivity is hindered by the photon shot noise. In this paper, we propose to introduce specific phase-shifting algorithms into the well-established quantum-enhanced MZI, seeded by coherent and squeezed vacuum states and followed by single-mode intensity detection and difference intensity detection, to achieve quantitative phase measurement with sensitivity beyond that achieved by the corresponding Mach-Zehnder-type PSI with classical input. We show that when the average photon number of the coherent state is dominant, the optimal phase sensitivity of the Mach-Zehnder-type PSI with coherent plus squeezed vacuum input is better than the phase sensitivity of the Mach-Zehnder-type PSI with single coherent input under the same phase-sensing intensity condition in both of detection setups. We also show that for the typical MZI seeded with a high-power coherent state and a finitely squeezed vacuum state, the combination of intensity detection and phase-shifting algorithm can still improve the sensitivity of quantitative phase measurement. Furthermore, we derive the phase sensitivity of the fixed MZI as well as the quantum Cramér-Rao bound for two detection schemes. Finally, we explore the impacts of photon losses on the phase sensitivity enhancements of the Mach-Zehnder-type PSI and the fixed MZI in the high-intensity regime for each detection setup. The robustness to losses is compared between the Mach-Zehnder-type PSI and the fixed MZI. Our results may be helpful to promote the exploration of quantum-enhanced quantitative phase sensing.
This paper provides a theoretical analysis of a Mach–Zehnder interferometer (MZI) enhanced by optical parametric amplifiers (OPA) placed inside its arms and fed by a coherent input source. Contrary to most cases found in literature, we perform a wider analysis by considering the MZI unbalanced and two internal phase shifts. We discuss the theoretical best-case phase sensitivity of this setup via the quantum Cramér–Rao bound (QCRB) and we consider scenarios having – or not – access to an external phase reference. We also assess the realistic performance of the OPA-enhanced MZI by employing a balanced homodyne detection (asymmetric and symmetric phase shifts) scheme and a difference-intensity detection scheme. We are thus able to find the optimum beam splitter (BS) transmissivity (transmission coefficient) of the first BS via the quantum Fisher information (QFI), while for the second one, we need to take the detection scheme into account. We are able to find these optimal values for all considered scenarios and thus assess the best-case phase sensitivity provided by this setup.