Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2510.17128 · Advanced Quantum Technologies

Phase Sensitivity of Lossy Mach–Zehnder Interferometer via Photon Addition Operation

Qisi Zhou, Qingqian Kang, Teng Zhao, Xin Su, Cunjin Liu, Liyun Hu

Published Dec 1, 2025• 0 citations
arXivHTMLPDF

Abstract

ABSTRACT Photon addition operations applied to squeezed states have been shown to significantly enhance phase sensitivity. In this work, we extend this approach by applying photon addition not only to coherent states but also within a Mach–Zehnder interferometer, using coherent and squeezed vacuum states as input. Both intensity‐difference and homodyne detection are used to evaluate photon addition schemes, and their phase sensitivities are compared under ideal and lossy conditions. We also analyze the quantum Fisher information of these two schemes. Results show that both schemes improve phase sensitivity, quantum Fisher information, and robustness against losses. In particular, photon addition within the interferometer performs better. Homodyne detection outperforms intensity difference detection under photon losses. Notably, the two schemes exhibit distinct parameter dependencies, rendering them suitable for different operational scenarios. When the squeezing parameter is small, photon addition employed at the coherent input with intensity difference detection can approach the Heisenberg limit in ideal conditions and can exceed the standard quantum limit in high‐loss conditions. The proposed scheme represents a valuable method for quantum precision measurements. PACS : 03.67.‐a, 05.30.‐d, 42.50,Dv, 03.65.Wj

DOI
10.1002/qute.202500881

Related papers

Phase sensitivity via photon-subtraction operations inside Mach-Zehnder interferometer

Zhou, Qisi, Kang, Qinqian, Jiang, Tao +4 more

Based on the conventional Mach-Zehnder interferometer, we propose a metrological scheme to improve phase sensitivity. In this scheme, we use a coherent state and a squeezed vacuum state as input states, employ multi-photon-subtraction operations and make intensity-detection or homodyne-detection. We study phase sensitivity, quantum Fisher information and quantum Cramér-Rao bound under both ideal and lossy conditions. The results indicate that choosing an appropriate detection method and photon subtraction scheme can significantly enhance the phase sensitivity and robustness against photon losses. Even under lossy conditions, the multi-photon subtraction schemes can surpass the standard quantum limit. Notably, the homodyne detection method can even break through the Heisenberg limit. Moreover, increasing the number of photon-subtracted can enhance both phase sensitivity and quantum Fisher information. This research highlights the significant value of this scheme in quantum precision measurement.

arXiv:2505.04499•May 7, 2025•0 citations

Optimization of the phase sensitivity through photon-subtraction inside the Mach-Zehnder interferometer

Qisi Zhou, Qingqian Kang, Teng Zhao +3 more

Abstract We propose a photon subtraction scheme within the Mach–Zehnder interferometer using a coherent state and a squeezed vacuum state as inputs. By systematically comparing intensity detection and homodyne detection methods, we demonstrate that strategically applied photon subtraction ( a -mode subtraction) significantly enhances the phase sensitivity of all detection methods. Under this configuration, homodyne detection achieves superior phase sensitivity and loss robustness compared to intensity detection. Remarkably, under 30% photon loss, the system surpasses the Heisenberg limit, enabled by the synergy among the squeezed vacuum state, non-Gaussian operations, and detection optimization. Furthermore, we quantify performance through the quantum Fisher information and the quantum Cramér-Rao bound analyses under both ideal and lossy conditions.

Journal of Physics B Atomic Molecular and Optical Physics•Apr 22, 2026•0 citations

Improved linear and Kerr nonlinear phase estimation via photon addition operations

Zekun Zhao, Qingqian Kang, Shoukang Chang +4 more

Abstract The precision of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shift. Here, we employ a coherent state mixed with a photon-added squeezed vacuum state as the input to a Mach–Zehnder interferometer with parity detection, thereby achieving a significant enhancement in phase measurement precision. Our research focuses on the phase sensitivity of linear phase shift under both ideal conditions and photon loss, as well as quantum Fisher information (QFI). The results demonstrate that employing the photon addition operations can markedly enhance phase sensitivity and QFI, and under optimal conditions, the measurement precision can approach the Heisenberg limit for the linear phase shift case. In addition, we delve deeper into the scenario of replacing the linear phase shift with a Kerr nonlinear one and systematically analyze the QFI under both ideal and photon loss conditions. By comparison, it is evident that employing both the photon addition operations and the Kerr nonlinear phase shift can further significantly enhance phase measurement precision while effectively improving the system’s robustness against photon loss. These findings are instrumental in facilitating the development and practical application of quantum metrology.

arXiv:2505.16123•Communications in Theoretical Physics•Feb 4, 2026•0 citations

High-sensitivity phase estimation with a two-mode squeezed coherent state based on a Mach–Zehnder interferometer

Pengxiang Ruan, Jun Liu, Chenlu Li +3 more

Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.

Chinese Physics B•Jul 28, 2025•0 citations

Quantum-enhanced super-sensitivity of Mach–Zehnder interferometer using squeezed Kerr state

Dhiraj Yadav, Gaurav K. Shukla, Priyanka Sharma +1 more

We study the phase super–sensitivity of a Mach–Zehnder interferometer (MZI) with the squeezed Kerr state (SKS) and coherent state as the inputs. We discuss the lower bound in phase sensitivity by considering the quantum Fisher information and the corresponding quantum Cramér–Rao bound. With the help of single intensity detection, intensity difference detection, and homodyne detection schemes, we find that our scheme gives a better sensitivity under both lossless and lossy conditions as compared to the well–known results of the combinations of inputs, such as coherent plus vacuum, coherent plus squeezed vacuum, and double coherent states. Because of the possibility of the generation of SKS with the present available quantum optical techniques, we expect that SKS may be an alternative nonclassical resource for the improvement in the phase super–sensitivity of the MZI in realistic scenarios.

arXiv:2309.04731•APL Quantum•Feb 23, 2024•22 citations

Robust phase sensitivity in Mach-Zehnder interferometer using photon added and subtracted squeezed coherent state

Shivani Singh, Priya Malpani, Anirban Pathak

For the precision-based measurements, Mach-Zehnder interferometry is a widely used technique. There are various ways to enhance the precision of Mach-Zehnder interferometer (MZI), e.g., having a non-classical input state is one of the ways to enhance the precision of the phase estimation performed by MZI. The phase estimation performed by MZI is investigated here by considering that the input states of MZI are different combinations of photon added and subtracted squeezed coherent states (PASCS and PSSCS). Using quantum Fisher information, it is shown that the use of PASCS in both the input modes of MZI, provides the most precise estimate of the unknown phase. This system is also analyzed in two different measurement scenarios -- single intensity detection (SID) and intensity difference detection (IDD). Systematic analysis has established that the intensity measurement might not be an optimal measurement scheme for phase estimation in MZI as phase and intensity correspond to non-commuting observables. The impact of the photon loss on the MZI-based phase estimation setup is also studied and it is found that PASCS is robust against photon loss, when the loss in MZI is low.

quant-pharXiv:2607.02984•Jul 6, 2026•0 citations
ABSTRACT Photon addition operations applied to squeezed states have been shown to significantly enhance phase sensitivity. In this work, we extend this approach by applying photon addition not only to coherent states but also within a Mach–Zehnder interferometer, using coherent and squeezed vacuum states as input. Both intensity‐difference and homodyne detection are used to evaluate photon addition schemes, and their phase sensitivities are compared under ideal and lossy conditions. We also analyze the quantum Fisher information of these two schemes. Results show that both schemes improve phase sensitivity, quantum Fisher information, and robustness against losses. In particular, photon addition within the interferometer performs better. Homodyne detection outperforms intensity difference detection under photon losses. Notably, the two schemes exhibit distinct parameter dependencies, rendering them suitable for different operational scenarios. When the squeezing parameter is small, photon addition employed at the coherent input with intensity difference detection can approach the Heisenberg limit in ideal conditions and can exceed the standard quantum limit in high‐loss conditions. The proposed scheme represents a valuable method for quantum precision measurements. PACS : 03.67.‐a, 05.30.‐d, 42.50,Dv, 03.65.Wj
Based on the conventional Mach-Zehnder interferometer, we propose a metrological scheme to improve phase sensitivity. In this scheme, we use a coherent state and a squeezed vacuum state as input states, employ multi-photon-subtraction operations and make intensity-detection or homodyne-detection. We study phase sensitivity, quantum Fisher information and quantum Cramér-Rao bound under both ideal and lossy conditions. The results indicate that choosing an appropriate detection method and photon subtraction scheme can significantly enhance the phase sensitivity and robustness against photon losses. Even under lossy conditions, the multi-photon subtraction schemes can surpass the standard quantum limit. Notably, the homodyne detection method can even break through the Heisenberg limit. Moreover, increasing the number of photon-subtracted can enhance both phase sensitivity and quantum Fisher information. This research highlights the significant value of this scheme in quantum precision measurement.
Abstract We propose a photon subtraction scheme within the Mach–Zehnder interferometer using a coherent state and a squeezed vacuum state as inputs. By systematically comparing intensity detection and homodyne detection methods, we demonstrate that strategically applied photon subtraction ( a -mode subtraction) significantly enhances the phase sensitivity of all detection methods. Under this configuration, homodyne detection achieves superior phase sensitivity and loss robustness compared to intensity detection. Remarkably, under 30% photon loss, the system surpasses the Heisenberg limit, enabled by the synergy among the squeezed vacuum state, non-Gaussian operations, and detection optimization. Furthermore, we quantify performance through the quantum Fisher information and the quantum Cramér-Rao bound analyses under both ideal and lossy conditions.
Abstract The precision of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shift. Here, we employ a coherent state mixed with a photon-added squeezed vacuum state as the input to a Mach–Zehnder interferometer with parity detection, thereby achieving a significant enhancement in phase measurement precision. Our research focuses on the phase sensitivity of linear phase shift under both ideal conditions and photon loss, as well as quantum Fisher information (QFI). The results demonstrate that employing the photon addition operations can markedly enhance phase sensitivity and QFI, and under optimal conditions, the measurement precision can approach the Heisenberg limit for the linear phase shift case. In addition, we delve deeper into the scenario of replacing the linear phase shift with a Kerr nonlinear one and systematically analyze the QFI under both ideal and photon loss conditions. By comparison, it is evident that employing both the photon addition operations and the Kerr nonlinear phase shift can further significantly enhance phase measurement precision while effectively improving the system’s robustness against photon loss. These findings are instrumental in facilitating the development and practical application of quantum metrology.
Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.
We study the phase super–sensitivity of a Mach–Zehnder interferometer (MZI) with the squeezed Kerr state (SKS) and coherent state as the inputs. We discuss the lower bound in phase sensitivity by considering the quantum Fisher information and the corresponding quantum Cramér–Rao bound. With the help of single intensity detection, intensity difference detection, and homodyne detection schemes, we find that our scheme gives a better sensitivity under both lossless and lossy conditions as compared to the well–known results of the combinations of inputs, such as coherent plus vacuum, coherent plus squeezed vacuum, and double coherent states. Because of the possibility of the generation of SKS with the present available quantum optical techniques, we expect that SKS may be an alternative nonclassical resource for the improvement in the phase super–sensitivity of the MZI in realistic scenarios.
For the precision-based measurements, Mach-Zehnder interferometry is a widely used technique. There are various ways to enhance the precision of Mach-Zehnder interferometer (MZI), e.g., having a non-classical input state is one of the ways to enhance the precision of the phase estimation performed by MZI. The phase estimation performed by MZI is investigated here by considering that the input states of MZI are different combinations of photon added and subtracted squeezed coherent states (PASCS and PSSCS). Using quantum Fisher information, it is shown that the use of PASCS in both the input modes of MZI, provides the most precise estimate of the unknown phase. This system is also analyzed in two different measurement scenarios -- single intensity detection (SID) and intensity difference detection (IDD). Systematic analysis has established that the intensity measurement might not be an optimal measurement scheme for phase estimation in MZI as phase and intensity correspond to non-commuting observables. The impact of the photon loss on the MZI-based phase estimation setup is also studied and it is found that PASCS is robust against photon loss, when the loss in MZI is low.