arXiv:1707.03874 · Journal of Applied Physics

Cryogenic LED pixel-to-frequency mapper for kinetic inductance detector arrays

X. Liu, Weijie Guo, Yiwen Wang, L. F. Wei, Christopher M. McKenney, Bradley Dober, Tashalee S. Billings, Johannes Hubmayr, Linda Ferreira, Michael R. Vissers, J. Gao

Published Jul 17, 2017• 15 citations
arXivHTMLPDF

Abstract

We present a cryogenic wafer mapper based on light emitting diodes (LEDs) for spatial mapping of a large microwave kinetic inductance detector (MKID) array. In this scheme, an array of LEDs, addressed by DC wires and collimated through horns onto the detectors, is mounted in front of the detector wafer. By illuminating each LED individually and sweeping the frequency response of all the resonators, we can unambiguously correspond a detector pixel to its measured resonance frequency. We have demonstrated mapping a 76.2 mm 90-pixel MKID array using a mapper containing 126 LEDs with 16 DC bias wires. With the frequency to pixel-position correspondence data obtained by the LED mapper, we have found a radially position-dependent frequency non-uniformity of ≲1.6% over the 76.2 mm wafer. Our LED wafer mapper has no moving parts and is easy to implement. It may find broad applications in superconducting detectors and quantum computing/information experiments.

DOI
10.1063/1.4994170

Related papers

In Situ Interferometric Spatial Mapping of a Microwave Kinetic Inductance Detector Array

Chris Albert, R. Basu Thakur, Farzad Faramarzi +7 more

We present a method of spatially mapping microwave kinetic inductance detector (MKID) arrays, in a dark setup. MKIDs are superconducting natively multiplexed resonators which enable kilopixel arrays, such as for the proposed Probe far-Infrared Mission for Astrophysics (PRIMA). In such telescope applications one must map the spatial location of each MKID with their individual resonance frequencies. Traditional LED arrays or beam-mapping methods become increasingly difficult as pixel spacing decreases, e.g., 900$\mu$m separated MKIDs in the spectrometer module of PRIMA. Our new mapping technique uses a cryogenic interferometer in reflection mode. As on-resonance signals reflect from an MKID, they accrue a phase proportional to the path-length, exactly corresponding to their physical distance on the feedline. Specifically, we use a superconducting transmission line that has nonlinear kinetic inductance. The slow-wave structure of this nonlinear device is designed to have a signal speed of 0.64% the speed of light, enabling a compact system. Current biasing this line allows for varying the wave speed and ensuring that the phase measured is periodic within a nulling interferometric mode. Using this setup, we measure a length ordering that reflects the bimodal MKID distribution of a 44 pixel array of MKIDs designed for PRIMA which contains the same spacing as the final kilopixel array design.

arXiv:2604.12287•IEEE Transactions on Applied Superconductivity•Mar 26, 2026•0 citations

Calibration Scheme for Large Kinetic Inductance Detector Arrays Based on Readout Frequency Response

Laura Bisigello, S. J. C. Yates, Vignesh Murugesan +2 more

Microwave kinetic inductance detector (MKID) provides a way to build large ground-based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over a wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that the shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousands of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.

arXiv:1602.00442•Journal of Low Temperature Physics•Feb 9, 2016•14 citations

Antenna-coupled Microwave Kinetic Inductance detectors (MKIDs) for mm and submm imaging arrays

Anastasios Vayonakis, James A. Schlaerth, S. Kumar +9 more

We present results from completely lithographic antenna-coupled Microwave Kinetic Inductance detectors (MKIDs). MKIDs are superconducting resonators with resonant frequency and quality-factor which are highly sensitive to changes in the density of the quasiparticle population which occurs when photons above the superconducting gap energy are absorbed. The resonators are coupled to submm light through on-chip phased-array slot antennas. Each planar antenna consists of an array of N long slots which are fed along their length at M points. The resulting N*M feed points are combined in-phase using a binary summing tree made of low-loss superconducting microstrip lines. Due to its large size, the resulting planar antenna produces a narrow beam pattern and can therefore be used without additional optical coupling elements such as feedhorns or substrate lenses. The output of the antenna is a single superconducting thin-film microstrip line which can be efficiently coupled to one (or more) kinetic inductance coplanar waveguide resonators to produce a single (or multi-color) pixel in an imaging focal plane array, using in-line lumped element lithographic band-pass filters. Such highly integrated architectures can be easily fabricated on a single substrate, and many detectors can be frequency multiplexed through coupling to a single feedline. Microwave readout provides a lot of bandwidth per detector, allowing a large number of pixels to be read using a single cryogenic microwave amplifier and warm readout electronics.

Softwaretechnik-Trends•Apr 1, 2008•1 citation

Multiplexable frequency retuning of MKID arrays using their non-linear kinetic inductance

Mario de Lucia, Eoin Baldwin, Gerhard Ulbricht +3 more

Microwave Kinetic Inductance Detector (MKID) arrays are currently being developed and deployed for astronomical applications in the visible and near infrared and for sub-millimetre astronomy. One of the main challenges of MKIDs is that large arrays would exhibit a pixel yield, defined as the percentage of individually distinguishable pixels to the total number of pixels, of 75 80 %.1 Imperfections arising during the fabrication can induce an uncontrolled shift in the resonance frequency of individual resonators which end up resonating at the same frequency of a different resonator. This makes a number of pixels indistinguishable and therefore unusable for imaging. This paper proposes an approach to individually re-tune the colliding resonators in order to remove the degeneracy and increase the number of MKIDs with unique resonant frequencies. The frequency re-tuning is achieved through a DC bias of the resonator since the kinetic inductance of a superconducting thin film is current dependent and its dependence is non linear. Even though this approach has been already proposed,2 our innovative pixel design may solve two issues previously described in literature such as non-negligible electromagnetic losses to the DC bias line, and the multiplexibility of multiple resonators on a single feed-line.

arXiv:2204.05715•X-Ray, Optical, and Infrared Detectors for Astronomy•Dec 11, 2020•2 citations

Evaluation of YBa2Cu3O7-δ-based microwave kinetic inductance detectors with rewound spiral resonators

Kaoru Sato, Seiichiro Ariyoshi, Shun Negishi +4 more

We propose a YBCO-based microwave kinetic inductance detector with rewound strip structure (spiral-MKID) suitable for imaging applications. The superconducting rewound strip acts as a microwave resonator and broadband antenna. A 25-pixel MKID array with a width of 10 μm and slightly varying length of each of the resonators was fabricated on a 10 × 10 mm 2 -MgO substrate. Microwave resonance characteristics of the array were evaluated by measuring one of the scattering-matrix elements, S 21 , using a vector network analyser. The 25 resonance dips were clearly observed around 5 GHz; the frequency spacing between adjacent pixels was 13 MHz, with a standard deviation of 5 MHz. Each resonance frequency was shifted by 170 MHz, owing to the temperature change from 11 K to 50 K. We showed that the YBCO-based spiral-MKIDs with 200 nm-thick films have loaded quality factors of 1,200 at 11 K and 700 at 50 K. We irradiated visible light to a single pixel on the array. The obtained noise equivalent power was on the order of 10 −9 W/Hz 1/2 , while the response time was smaller than 30 ms at 13 K. The responsivity of the array at 70 K was six times larger than that at 13 K.

Journal of Physics Conference Series•Jul 1, 2018•6 citations

Characterization of the quasiparticle lifetime of microwave kinetic inductance detector

Zhi Li, Wei-Tao Lv, Qing Shi +3 more

We design and fabricate a 350GHz 8×8 Al Microwave Kinetic Inductance Detector (MKIDs) array for the demonstration of its characteristics, mainly focus on the quasiparticle lifetime of the resonators. The quasiparticle lifetime data is collected by measuring a resonator’s phase response to a LED pulse at resonant frequency in a dilution refrigerator cooled to mK stage. We also measure and discuss the influence of various parameters on the change of quasiparticle lifetime, including different LED voltage supply, bath temperature of the MKIDs, and superconducting film thickness.

•Nov 24, 2021•0 citations
We present a cryogenic wafer mapper based on light emitting diodes (LEDs) for spatial mapping of a large microwave kinetic inductance detector (MKID) array. In this scheme, an array of LEDs, addressed by DC wires and collimated through horns onto the detectors, is mounted in front of the detector wafer. By illuminating each LED individually and sweeping the frequency response of all the resonators, we can unambiguously correspond a detector pixel to its measured resonance frequency. We have demonstrated mapping a 76.2 mm 90-pixel MKID array using a mapper containing 126 LEDs with 16 DC bias wires. With the frequency to pixel-position correspondence data obtained by the LED mapper, we have found a radially position-dependent frequency non-uniformity of ≲1.6% over the 76.2 mm wafer. Our LED wafer mapper has no moving parts and is easy to implement. It may find broad applications in superconducting detectors and quantum computing/information experiments.
We present a method of spatially mapping microwave kinetic inductance detector (MKID) arrays, in a dark setup. MKIDs are superconducting natively multiplexed resonators which enable kilopixel arrays, such as for the proposed Probe far-Infrared Mission for Astrophysics (PRIMA). In such telescope applications one must map the spatial location of each MKID with their individual resonance frequencies. Traditional LED arrays or beam-mapping methods become increasingly difficult as pixel spacing decreases, e.g., 900μ\muμm separated MKIDs in the spectrometer module of PRIMA. Our new mapping technique uses a cryogenic interferometer in reflection mode. As on-resonance signals reflect from an MKID, they accrue a phase proportional to the path-length, exactly corresponding to their physical distance on the feedline. Specifically, we use a superconducting transmission line that has nonlinear kinetic inductance. The slow-wave structure of this nonlinear device is designed to have a signal speed of 0.64% the speed of light, enabling a compact system. Current biasing this line allows for varying the wave speed and ensuring that the phase measured is periodic within a nulling interferometric mode. Using this setup, we measure a length ordering that reflects the bimodal MKID distribution of a 44 pixel array of MKIDs designed for PRIMA which contains the same spacing as the final kilopixel array design.
Microwave kinetic inductance detector (MKID) provides a way to build large ground-based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over a wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that the shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousands of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.
We present results from completely lithographic antenna-coupled Microwave Kinetic Inductance detectors (MKIDs). MKIDs are superconducting resonators with resonant frequency and quality-factor which are highly sensitive to changes in the density of the quasiparticle population which occurs when photons above the superconducting gap energy are absorbed. The resonators are coupled to submm light through on-chip phased-array slot antennas. Each planar antenna consists of an array of N long slots which are fed along their length at M points. The resulting N*M feed points are combined in-phase using a binary summing tree made of low-loss superconducting microstrip lines. Due to its large size, the resulting planar antenna produces a narrow beam pattern and can therefore be used without additional optical coupling elements such as feedhorns or substrate lenses. The output of the antenna is a single superconducting thin-film microstrip line which can be efficiently coupled to one (or more) kinetic inductance coplanar waveguide resonators to produce a single (or multi-color) pixel in an imaging focal plane array, using in-line lumped element lithographic band-pass filters. Such highly integrated architectures can be easily fabricated on a single substrate, and many detectors can be frequency multiplexed through coupling to a single feedline. Microwave readout provides a lot of bandwidth per detector, allowing a large number of pixels to be read using a single cryogenic microwave amplifier and warm readout electronics.
Microwave Kinetic Inductance Detector (MKID) arrays are currently being developed and deployed for astronomical applications in the visible and near infrared and for sub-millimetre astronomy. One of the main challenges of MKIDs is that large arrays would exhibit a pixel yield, defined as the percentage of individually distinguishable pixels to the total number of pixels, of 75 80 %.1 Imperfections arising during the fabrication can induce an uncontrolled shift in the resonance frequency of individual resonators which end up resonating at the same frequency of a different resonator. This makes a number of pixels indistinguishable and therefore unusable for imaging. This paper proposes an approach to individually re-tune the colliding resonators in order to remove the degeneracy and increase the number of MKIDs with unique resonant frequencies. The frequency re-tuning is achieved through a DC bias of the resonator since the kinetic inductance of a superconducting thin film is current dependent and its dependence is non linear. Even though this approach has been already proposed,2 our innovative pixel design may solve two issues previously described in literature such as non-negligible electromagnetic losses to the DC bias line, and the multiplexibility of multiple resonators on a single feed-line.
We propose a YBCO-based microwave kinetic inductance detector with rewound strip structure (spiral-MKID) suitable for imaging applications. The superconducting rewound strip acts as a microwave resonator and broadband antenna. A 25-pixel MKID array with a width of 10 μm and slightly varying length of each of the resonators was fabricated on a 10 × 10 mm 2 -MgO substrate. Microwave resonance characteristics of the array were evaluated by measuring one of the scattering-matrix elements, S 21 , using a vector network analyser. The 25 resonance dips were clearly observed around 5 GHz; the frequency spacing between adjacent pixels was 13 MHz, with a standard deviation of 5 MHz. Each resonance frequency was shifted by 170 MHz, owing to the temperature change from 11 K to 50 K. We showed that the YBCO-based spiral-MKIDs with 200 nm-thick films have loaded quality factors of 1,200 at 11 K and 700 at 50 K. We irradiated visible light to a single pixel on the array. The obtained noise equivalent power was on the order of 10 −9 W/Hz 1/2 , while the response time was smaller than 30 ms at 13 K. The responsivity of the array at 70 K was six times larger than that at 13 K.
We design and fabricate a 350GHz 8×8 Al Microwave Kinetic Inductance Detector (MKIDs) array for the demonstration of its characteristics, mainly focus on the quasiparticle lifetime of the resonators. The quasiparticle lifetime data is collected by measuring a resonator’s phase response to a LED pulse at resonant frequency in a dilution refrigerator cooled to mK stage. We also measure and discuss the influence of various parameters on the change of quasiparticle lifetime, including different LED voltage supply, bath temperature of the MKIDs, and superconducting film thickness.