arXiv:1610.00725 · Applied Physics Letters

High quality factor platinum silicide microwave kinetic inductance detectors

Paul Szypryt, B. A. Mazin, G. Ulbricht, B. Bumble, S. R. Meeker, C. Bockstiegel, A. B. Walter

Published Oct 10, 2016• 34 citations
arXivHTMLPDF

Abstract

We report on the development of microwave kinetic inductance detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single photons to better than two microseconds and their energies to around ten percent. Previously, MKIDs have been fabricated using either sub-stoichiometric titanium nitride or aluminum, but TiN suffers from the spatial inhomogeneities in the superconducting critical temperature and Al has a low kinetic inductance fraction, causing low detector sensitivity. To address these issues, we have instead fabricated the PtSi microresonators with the superconducting critical temperatures of 944 ± 12 mK and high internal quality factors (Qi≳106). These devices show typical quasiparticle lifetimes of τqp≈30–40 μs and spectral resolution, R=λ/Δλ, of 8 at 406.6 nm. We compare PtSi MKIDs to those fabricated with TiN and detail the substantial advantages that PtSi MKIDs have to offer.

DOI
10.1063/1.4964665

Related papers

Tungsten silicide films for kinetic inductance detectors

T. Cecil, Antonino Miceli, Orlando Quaranta +4 more

Microwave Kinetic Inductance Detectors (MKIDs) provide highly multiplexed arrays of detectors that can be configured to operate from the sub-millimeter to the X-ray regime. We have examined two tungsten silicide alloys (W5Si3 and WSi2), which are dense alloys that provide a critical temperature tunable with composition, large kinetic inductance fraction, and high normal-state resistivity. We have fabricated quarter wavelength CPW superconducting resonators and provide measurement data on critical temperature, surface resistance, quality factor, noise, and quasiparticle lifetime. Tungsten silicide appears to be very promising for kinetic inductance detectors.

•Mar 22, 2012•0 citations

Design and performance of hafnium optical and near-IR kinetic inductance detectors

Nicholas Zobrist, Grégoire Coiffard, Bruce Bumble +9 more

We report on the design and performance of microwave kinetic inductance detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 μΩ cm with RRR=1.6. Resonators on the device displayed internal quality factors of around 200 000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process, which resulted in pixels with decay times of about 40 μs and resolving powers of ∼9 at 800 nm.

arXiv:1911.06434•Applied Physics Letters•Nov 18, 2019•28 citations

Optimizing Ti/TiN Multilayers for UV, Optical and Near-IR Microwave Kinetic Inductance Detectors

Gerhard Ulbricht, Mario de Lucia, Jack Piercy +4 more

Abstract Microwave Kinetic Inductance Detectors (MKIDs) combine significant advantages for photon detection like single photon counting, single pixel energy resolution, vanishing dark counts and µs time resolution with a simple design and the feasibility to scale up into the megapixel range. But high quality MKID fabrication remains challenging as established superconductors tend to either have intrinsic disadvantages, are challenging to deposit or require very low operating temperatures. As alternating stacks of thin Ti and TiN films have shown very impressive results for far-IR and sub-mm MKIDs, they promise significant improvements for UV, visible to near-IR MKIDs as well, especially as they are comparably easy to fabricate and control. In this paper, we present our ongoing project to adapt proximity coupled superconducting films for photon counting MKIDs. Some of the main advantages of Ti/TiN multilayers are their good control of critical temperature (Tc) and their great homogeneity of Tc even over large wafers, promising improved pixel yield especially for large arrays. We demonstrate the effect different temperatures during fabrication have on the detector performance and discuss excess phase noise observed caused by surface oxidization of exposed Si. Our first prototypes achieved photon energy resolving powers of up to 3.1 but turned out to be much too insensitive. As the work presented is still in progress, we also discuss further improvements planned for the near future.

Journal of Low Temperature Physics•May 15, 2024•1 citation

Tungsten silicide films for microwave kinetic inductance detectors

T. Cecil, Antonino Miceli, Orlando Quaranta +4 more

Microwave kinetic inductance detectors provide highly multiplexed arrays of detectors that can be configured to operate from the sub-millimeter to the x-ray regime. We have examined two tungsten silicide alloys (W5Si3 and WSi2), which are dense alloys that provide a critical temperature tunable with composition, large kinetic inductance fraction, and high normal-state resistivity. We have fabricated superconducting resonators and provide measurement data on critical temperature, surface resistance, quality factor, noise, and quasiparticles lifetime. Tungsten silicide appears to be promising for microwave kinetic inductance detectors.

arXiv:1203.5064•Applied Physics Letters•Jul 16, 2012•23 citations

Study of Superconducting Bilayer for Microwave Kinetic Inductance Detectors for Astrophysics

Agnès Dominjon, Masakazu Sekine, K. Karatsu +5 more

Due to their multiplexing capability and their good sensitivity to radiation from submillimeter to X-ray wavelengths, microwave kinetic inductance detectors (MKIDs) are increasingly used in the field of astrophysics. The Advanced Technology Center of the National Astronomical Observatory of Japan is developing MKIDs for astronomical observations such as CMB B-mode search with LiteBIRD. MKIDs are made of superconductors whose energy gap determines the detector frequency range. The energy gap depends on Tc, the critical temperature of the superconductor. It is thus important to be able to adjust Tc in order to choose the suitable frequency range. When using a single-layer MKID, the Tc is fixed by the superconducting gap energy of the unique component and cannot be changed. One possibility is to make a bilayer MKID using the proximity effect to adjust its critical temperature. This paper presents our new study on MKIDs made of superconductor/metal bilayers. We investigated niobium and copper bilayers (Nb/Cu) and fabricated different bilayers in our clean room. The critical temperature of each of them has been measured. We show that the Tc depends on the ratio between Nb and Cu thicknesses and that we are able to control it. Then, we characterized one of these Nb/Cu bilayers (Nb = 8 nm and Cu = 22 nm) once integrated in a MKID. We measured the temperature dependence of the resonant frequency, and we achieved quality factors as high as 2 × 104. The measurement of the noise spectrum provided a lower limit equal to -85 dBc/Hz, and the calculation of the noise equivalent power has shown that the sensitivity of the Nb/Cu bilayer MKID is not very far from that of an Al monolayer MKID.

IEEE Transactions on Applied Superconductivity•Feb 19, 2016•16 citations

Design and measurement of superconducting microwave kinetic inductance detectors

Florian Blauth

Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.

•Oct 1, 2019•0 citations
We report on the development of microwave kinetic inductance detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single photons to better than two microseconds and their energies to around ten percent. Previously, MKIDs have been fabricated using either sub-stoichiometric titanium nitride or aluminum, but TiN suffers from the spatial inhomogeneities in the superconducting critical temperature and Al has a low kinetic inductance fraction, causing low detector sensitivity. To address these issues, we have instead fabricated the PtSi microresonators with the superconducting critical temperatures of 944 ± 12 mK and high internal quality factors (Qi≳106). These devices show typical quasiparticle lifetimes of τqp≈30–40 μs and spectral resolution, R=λ/Δλ, of 8 at 406.6 nm. We compare PtSi MKIDs to those fabricated with TiN and detail the substantial advantages that PtSi MKIDs have to offer.
Microwave Kinetic Inductance Detectors (MKIDs) provide highly multiplexed arrays of detectors that can be configured to operate from the sub-millimeter to the X-ray regime. We have examined two tungsten silicide alloys (W5Si3 and WSi2), which are dense alloys that provide a critical temperature tunable with composition, large kinetic inductance fraction, and high normal-state resistivity. We have fabricated quarter wavelength CPW superconducting resonators and provide measurement data on critical temperature, surface resistance, quality factor, noise, and quasiparticle lifetime. Tungsten silicide appears to be very promising for kinetic inductance detectors.
We report on the design and performance of microwave kinetic inductance detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 μΩ cm with RRR=1.6. Resonators on the device displayed internal quality factors of around 200 000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process, which resulted in pixels with decay times of about 40 μs and resolving powers of ∼9 at 800 nm.
Abstract Microwave Kinetic Inductance Detectors (MKIDs) combine significant advantages for photon detection like single photon counting, single pixel energy resolution, vanishing dark counts and µs time resolution with a simple design and the feasibility to scale up into the megapixel range. But high quality MKID fabrication remains challenging as established superconductors tend to either have intrinsic disadvantages, are challenging to deposit or require very low operating temperatures. As alternating stacks of thin Ti and TiN films have shown very impressive results for far-IR and sub-mm MKIDs, they promise significant improvements for UV, visible to near-IR MKIDs as well, especially as they are comparably easy to fabricate and control. In this paper, we present our ongoing project to adapt proximity coupled superconducting films for photon counting MKIDs. Some of the main advantages of Ti/TiN multilayers are their good control of critical temperature (Tc) and their great homogeneity of Tc even over large wafers, promising improved pixel yield especially for large arrays. We demonstrate the effect different temperatures during fabrication have on the detector performance and discuss excess phase noise observed caused by surface oxidization of exposed Si. Our first prototypes achieved photon energy resolving powers of up to 3.1 but turned out to be much too insensitive. As the work presented is still in progress, we also discuss further improvements planned for the near future.
Microwave kinetic inductance detectors provide highly multiplexed arrays of detectors that can be configured to operate from the sub-millimeter to the x-ray regime. We have examined two tungsten silicide alloys (W5Si3 and WSi2), which are dense alloys that provide a critical temperature tunable with composition, large kinetic inductance fraction, and high normal-state resistivity. We have fabricated superconducting resonators and provide measurement data on critical temperature, surface resistance, quality factor, noise, and quasiparticles lifetime. Tungsten silicide appears to be promising for microwave kinetic inductance detectors.
Due to their multiplexing capability and their good sensitivity to radiation from submillimeter to X-ray wavelengths, microwave kinetic inductance detectors (MKIDs) are increasingly used in the field of astrophysics. The Advanced Technology Center of the National Astronomical Observatory of Japan is developing MKIDs for astronomical observations such as CMB B-mode search with LiteBIRD. MKIDs are made of superconductors whose energy gap determines the detector frequency range. The energy gap depends on Tc, the critical temperature of the superconductor. It is thus important to be able to adjust Tc in order to choose the suitable frequency range. When using a single-layer MKID, the Tc is fixed by the superconducting gap energy of the unique component and cannot be changed. One possibility is to make a bilayer MKID using the proximity effect to adjust its critical temperature. This paper presents our new study on MKIDs made of superconductor/metal bilayers. We investigated niobium and copper bilayers (Nb/Cu) and fabricated different bilayers in our clean room. The critical temperature of each of them has been measured. We show that the Tc depends on the ratio between Nb and Cu thicknesses and that we are able to control it. Then, we characterized one of these Nb/Cu bilayers (Nb = 8 nm and Cu = 22 nm) once integrated in a MKID. We measured the temperature dependence of the resonant frequency, and we achieved quality factors as high as 2 × 104. The measurement of the noise spectrum provided a lower limit equal to -85 dBc/Hz, and the calculation of the noise equivalent power has shown that the sensitivity of the Nb/Cu bilayer MKID is not very far from that of an Al monolayer MKID.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.