arXiv:1511.07277 · Physical Review Letters

Atomic Quadrupole Moment Measurement Using Dynamic Decoupling

Ravid Shaniv, N. Akerman, Roee Ozeri

Published Apr 8, 2016• 18 citations
arXivHTMLPDF

Abstract

We present a method that uses dynamic decoupling of a multilevel quantum probe to distinguish small frequency shifts that depend on m_{j}^{2}, where m_{j}^{2} is the angular momentum of level |j⟩ along the quantization axis, from large noisy shifts that are linear in m_{j}, such as those due to magnetic field noise. Using this method we measured the electric-quadrupole moment of the 4D_{5/2} level in ^{88}Sr^{+} to be 2.973_{-0.033}^{+0.026}ea_{0}^{2}. Our measurement improves the uncertainty of this value by an order of magnitude and thus helps mitigate an important systematic uncertainty in ^{88}Sr^{+} based optical atomic clocks and verifies complicated many-body quantum calculations.

DOI
10.1103/physrevlett.116.140801

Related papers

Measurement of the Electric Quadrupole Moment of the 4d D5/22 Level in Sr+88

G. P. Barwood, Helen S. Margolis, Guozheng Huang +2 more

The quadrupole moment of the 4d (2)D(5/2) level in 88Sr+ has been measured to be 2.6(3)ea(2)(0), where a(0) is the Bohr radius and e the elementary charge. A single laser-cooled strontium ion was confined in an end cap trap with a variable dc quadrupole potential, and measurements were made on the 5s (2)S(1/2)-4d (2)D(5/2) transition at 674 nm using a femtosecond optical frequency comb. This work shows that measurements of the unperturbed 88Sr+ transition frequency with sub-Hz uncertainty are possible and is important in understanding the reproducibility of ion trap optical frequency standards.

Physical Review Letters•Sep 22, 2004•78 citations

Quadrupole Shift Cancellation Using Dynamic Decoupling

Ravid Shaniv, Nitzan Akerman, Tom Manovitz +2 more

We present a method that uses radio-frequency pulses to cancel the quadrupole shift in optical clock transitions. Quadrupole shifts are an inherent inhomogeneous broadening mechanism in trapped ion crystals and impose one of the limitations forcing current optical ion clocks to work with a single probe ion. Canceling this shift, at each interrogation cycle of the ion frequency, reduces the complexity in using N>1 ions in clocks, thus allowing for a reduction of the instability in the clock frequency by sqrt[N] according to the standard quantum limit. Our sequence relies on the tensorial nature of the quadrupole shift, and thus also cancels other tensorial shifts, such as the tensor ac stark shift. We experimentally demonstrate our sequence on three and seven ^{88}Sr^{+} ions trapped in a linear Paul trap, using correlation spectroscopy. We show a reduction of the quadrupole shift difference between ions to the ≈10 mHz level where other shifts, such as the relativistic second-order Doppler shift, are expected to limit our spectral resolution. In addition, we show that using radio-frequency dynamic decoupling we can also cancel the effect of first-order Zeeman shifts.

arXiv:1808.10727•Physical Review Letters•Jun 5, 2019•25 citations

Coherent Suppression of Tensor Frequency Shifts through Magnetic Field Rotation

R. Lange, Nils Huntemann, Christian Sanner +4 more

We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to the electric quadrupole interaction, we experimentally demonstrate suppression by more than two orders of magnitude for the ^{2}S_{1/2}→^{2}D_{3/2} transition of a single trapped ^{171}Yb^{+} ion. The scheme provides particular advantages in the case of the ^{171}Yb^{+} ^{2}S_{1/2}→^{2}F_{7/2} electric octupole (E3) transition. For an improved estimate of the residual quadrupole shift for this transition, we measure the excited state electric quadrupole moments Θ(^{2}D_{3/2})=1.95(1)ea_{0}^{2} and Θ(^{2}F_{7/2})=-0.0297(5)ea_{0}^{2} with e the elementary charge and a_{0} the Bohr radius, improving the measurement uncertainties by one order of magnitude.

arXiv:2005.14687•Physical Review Letters•Sep 28, 2020•19 citations

Multi-ion frequency reference using dynamical decoupling

Lennart Pelzer, Kai Dietze, V. J. Martínez-Lahuerta +6 more

We present the experimental realization of a continuous dynamical decoupling scheme which suppresses leading frequency shifts in a multi-ion frequency reference based on $^{40}\mathrm{Ca}^+$. By near-resonant magnetic coupling of the $^2\mathrm{S}_{1/2}$ and $^2\mathrm{D}_{5/2}$ Zeeman sub-levels using radio-frequency dressing fields, engineered transitions with reduced sensitivity to magnetic-field fluctuations are obtained. A second stage detuned dressing field reduces the influence of amplitude noise in the first stage driving fields and decreases 2\textsuperscript{nd}-rank tensor shifts, such as the electric quadrupole shift. Suppression of the quadratic dependence of the quadrupole shift to $3(2)\,\text{mHz}/μm^2$ and coherence times of $290(20)\,\text{ms}$ on the optical transition are demonstrated even within a laboratory environment with significant magnetic field noise. Besides removing inhomogeneous line shifts in multi-ion clocks, the demonstrated dynamical decoupling technique may find applications in quantum computing and simulation with trapped ions by a tailored design of decoherence-free subspaces.

arXiv:2311.13736•Nov 22, 2023•0 citations

Operating a Multi-Ion Clock with Dynamical Decoupling

Nitzan Akerman, Roee Ozeri

We study and characterize a quasicontinuous dynamical decoupling scheme that effectively suppresses dominant frequency shifts in a multi-ion optical clock. Addressing the challenge of inhomogeneous frequency shifts in such systems, our scheme mitigates primary contributors, namely, the electric quadrupole and the linear Zeeman shifts. Based on ^{88}Sr^{+} ions, we implement the scheme in linear chains of up to 7 ions and demonstrate a significant suppression of the shift by more than 3 orders of magnitude, leading to relative frequency inhomogeneity below 7×10^{-17}. Additionally, we evaluate the associated systematic shift arising from the radio-frequency drive used in the QCDD scheme, showing that, in the presented realization, its contribution to the systematic relative frequency uncertainty is below 10^{-17}, with the potential for further improvement. These results provide a promising avenue toward implementing multi-ion clocks exhibiting an order of magnitude or more improvement in stability while maintaining a similar high degree of accuracy to that of single-ion clocks.

arXiv:2408.05280•Physical Review Letters•Jan 8, 2025•4 citations

The mercury-ion optical clock: towards a measurement of the quadrupole shift

Windell H. Oskay, A. Bartels, Scott A. Diddams +6 more

An optical clock based upon a single mercury ion in a radio-frequency trap has the potential for both high stability and high accuracy. The systematic uncertainty of this frequency standard is limited by contributions due to two types of external fields. The clock has previously been operated with a magnetic bias field that destabilizes dark states that limit the rates of laser cooling and state detection. This bias field has previously resulted in a substantial second-order Zeeman shift. We now destabilize the dark states with a polarization-scrambling technique that allows us to operate with only a minimal magnetic field. The second uncertainty that we address here is the magnitude of the quadrupole shift due to the interaction of stray electric-field gradients with the quadrupole moment of the ion. We describe the steps that we are taking to evaluate this shift in the near future. 1

European Frequency and Time Forum•Jan 1, 2004•2 citations
We present a method that uses dynamic decoupling of a multilevel quantum probe to distinguish small frequency shifts that depend on m_{j}^{2}, where m_{j}^{2} is the angular momentum of level |j⟩ along the quantization axis, from large noisy shifts that are linear in m_{j}, such as those due to magnetic field noise. Using this method we measured the electric-quadrupole moment of the 4D_{5/2} level in ^{88}Sr^{+} to be 2.973_{-0.033}^{+0.026}ea_{0}^{2}. Our measurement improves the uncertainty of this value by an order of magnitude and thus helps mitigate an important systematic uncertainty in ^{88}Sr^{+} based optical atomic clocks and verifies complicated many-body quantum calculations.
The quadrupole moment of the 4d (2)D(5/2) level in 88Sr+ has been measured to be 2.6(3)ea(2)(0), where a(0) is the Bohr radius and e the elementary charge. A single laser-cooled strontium ion was confined in an end cap trap with a variable dc quadrupole potential, and measurements were made on the 5s (2)S(1/2)-4d (2)D(5/2) transition at 674 nm using a femtosecond optical frequency comb. This work shows that measurements of the unperturbed 88Sr+ transition frequency with sub-Hz uncertainty are possible and is important in understanding the reproducibility of ion trap optical frequency standards.
We present a method that uses radio-frequency pulses to cancel the quadrupole shift in optical clock transitions. Quadrupole shifts are an inherent inhomogeneous broadening mechanism in trapped ion crystals and impose one of the limitations forcing current optical ion clocks to work with a single probe ion. Canceling this shift, at each interrogation cycle of the ion frequency, reduces the complexity in using N>1 ions in clocks, thus allowing for a reduction of the instability in the clock frequency by sqrt[N] according to the standard quantum limit. Our sequence relies on the tensorial nature of the quadrupole shift, and thus also cancels other tensorial shifts, such as the tensor ac stark shift. We experimentally demonstrate our sequence on three and seven ^{88}Sr^{+} ions trapped in a linear Paul trap, using correlation spectroscopy. We show a reduction of the quadrupole shift difference between ions to the ≈10 mHz level where other shifts, such as the relativistic second-order Doppler shift, are expected to limit our spectral resolution. In addition, we show that using radio-frequency dynamic decoupling we can also cancel the effect of first-order Zeeman shifts.
We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to the electric quadrupole interaction, we experimentally demonstrate suppression by more than two orders of magnitude for the ^{2}S_{1/2}→^{2}D_{3/2} transition of a single trapped ^{171}Yb^{+} ion. The scheme provides particular advantages in the case of the ^{171}Yb^{+} ^{2}S_{1/2}→^{2}F_{7/2} electric octupole (E3) transition. For an improved estimate of the residual quadrupole shift for this transition, we measure the excited state electric quadrupole moments Θ(^{2}D_{3/2})=1.95(1)ea_{0}^{2} and Θ(^{2}F_{7/2})=-0.0297(5)ea_{0}^{2} with e the elementary charge and a_{0} the Bohr radius, improving the measurement uncertainties by one order of magnitude.
We present the experimental realization of a continuous dynamical decoupling scheme which suppresses leading frequency shifts in a multi-ion frequency reference based on 40Ca+^{40}\mathrm{Ca}^+40Ca+. By near-resonant magnetic coupling of the 2S1/2^2\mathrm{S}_{1/2}2S1/2​ and 2D5/2^2\mathrm{D}_{5/2}2D5/2​ Zeeman sub-levels using radio-frequency dressing fields, engineered transitions with reduced sensitivity to magnetic-field fluctuations are obtained. A second stage detuned dressing field reduces the influence of amplitude noise in the first stage driving fields and decreases 2\textsuperscript{nd}-rank tensor shifts, such as the electric quadrupole shift. Suppression of the quadratic dependence of the quadrupole shift to 3(2) mHz/μm23(2)\,\text{mHz}/μm^23(2)mHz/μm2 and coherence times of 290(20) ms290(20)\,\text{ms}290(20)ms on the optical transition are demonstrated even within a laboratory environment with significant magnetic field noise. Besides removing inhomogeneous line shifts in multi-ion clocks, the demonstrated dynamical decoupling technique may find applications in quantum computing and simulation with trapped ions by a tailored design of decoherence-free subspaces.
We study and characterize a quasicontinuous dynamical decoupling scheme that effectively suppresses dominant frequency shifts in a multi-ion optical clock. Addressing the challenge of inhomogeneous frequency shifts in such systems, our scheme mitigates primary contributors, namely, the electric quadrupole and the linear Zeeman shifts. Based on ^{88}Sr^{+} ions, we implement the scheme in linear chains of up to 7 ions and demonstrate a significant suppression of the shift by more than 3 orders of magnitude, leading to relative frequency inhomogeneity below 7×10^{-17}. Additionally, we evaluate the associated systematic shift arising from the radio-frequency drive used in the QCDD scheme, showing that, in the presented realization, its contribution to the systematic relative frequency uncertainty is below 10^{-17}, with the potential for further improvement. These results provide a promising avenue toward implementing multi-ion clocks exhibiting an order of magnitude or more improvement in stability while maintaining a similar high degree of accuracy to that of single-ion clocks.
An optical clock based upon a single mercury ion in a radio-frequency trap has the potential for both high stability and high accuracy. The systematic uncertainty of this frequency standard is limited by contributions due to two types of external fields. The clock has previously been operated with a magnetic bias field that destabilizes dark states that limit the rates of laser cooling and state detection. This bias field has previously resulted in a substantial second-order Zeeman shift. We now destabilize the dark states with a polarization-scrambling technique that allows us to operate with only a minimal magnetic field. The second uncertainty that we address here is the magnitude of the quadrupole shift due to the interaction of stray electric-field gradients with the quadrupole moment of the ion. We describe the steps that we are taking to evaluate this shift in the near future. 1