An optical clock based upon a single mercury ion in a radio-frequency trap has the potential for both high stability and high accuracy. The systematic uncertainty of this frequency standard is limited by contributions due to two types of external fields. The clock has previously been operated with a magnetic bias field that destabilizes dark states that limit the rates of laser cooling and state detection. This bias field has previously resulted in a substantial second-order Zeeman shift. We now destabilize the dark states with a polarization-scrambling technique that allows us to operate with only a minimal magnetic field. The second uncertainty that we address here is the magnitude of the quadrupole shift due to the interaction of stray electric-field gradients with the quadrupole moment of the ion. We describe the steps that we are taking to evaluate this shift in the near future. 1
An optical clock based upon a single mercury ion in a radio-frequency trap has the potential for both high stability and high accuracy. The systematic uncertainty of this frequency standard is limited by contributions due to two types of external fields. The clock has previously been operated with a magnetic bias field that destabilizes dark states that limit the rates of laser cooling and state detection. This bias field has previously resulted in a substantial second-order Zeeman shift. We now destabilize the dark states with a polarization-scrambling technique that allows us to operate with only a minimal magnetic field. The second uncertainty that we address here is the magnitude of the quadrupole shift due to the interaction of stray electric-field gradients with the quadrupole moment of the ion. We describe the steps that we are taking to evaluate this shift in the near future. 1
Abstract Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.
We report the first operation of a Ra+ optical clock, a promising high-performance clock candidate. The clock uses a single trapped 226Ra+ ion and operates on the $7s\text{ }^{2}{S}_{1/2}\ensuremath{\rightarrow}6d\text{ }^{2}{D}_{5/2}$ electric quadrupole transition. By self-referencing three pairs of symmetric Zeeman transitions, we demonstrate a frequency instability of $1.1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/\sqrt{\ensuremath{\tau}}$, where $\ensuremath{\tau}$ is the averaging time in seconds. The total systematic uncertainty is evaluated to be $\mathrm{\ensuremath{\Delta}}\ensuremath{\nu}/\ensuremath{\nu}=9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$. Using the clock, we realize the first measurement of the ratio of the D5/2 state to the S1/2 state Land\'e g-factors: gD/gS=0.5988053(11). A Ra+ optical clock could improve limits on the time variation of the fine structure constant, $\stackrel{\ifmmode \dot{}\else \textperiodcentered \fi{}}{\ensuremath{\alpha}}/\ensuremath{\alpha}$, in an optical frequency comparison. The ion also has several features that make it a suitable system for a transportable optical clock.
We explore the potential of the electric quadrupole transitions 7s2S1/2 - 6d2D3/2, 6d2D5/2 in radium isotopes as single-ion optical frequency standards. The frequency shifts of the clock transitions due to external fields and the corresponding uncertainties are calculated. Several competitive ARa+ candidates with A= 223 - 229 are identified. In particular, we show that the transition 7s2S1/2(F=2,mF=0) - 6d2D3/2(F=0,mF=0) at 828 nm in 223Ra+, with no linear Zeeman and electric quadrupole shifts, stands out as a relatively simple case, which could be exploited as a compact, robust, and low-cost atomic clock operating at a fractional frequency uncertainty of 10−17. With more experimental effort, the 223,225,226Ra+ clocks could be pushed to a projected performance reaching the 10−18 level.
Abstract We present a novel method for engineering an optical clock transition that is robust against external field fluctuations and is able to overcome limits resulting from field inhomogeneities. The technique is based on the application of continuous driving fields to form a pair of dressed states essentially free of all relevant shifts. Specifically, the clock transition is robust to magnetic field shifts, quadrupole and other tensor shifts, and amplitude fluctuations of the driving fields. The scheme is applicable to either a single ion or an ensemble of ions, and is relevant for several types of ions, such as 40 Ca + , 88 Sr + , 138 Ba + and 176 Lu + . Taking a spherically symmetric Coulomb crystal formed by 400 40 Ca + ions as an example, we show through numerical simulations that the inhomogeneous linewidth of tens of Hertz in such a crystal together with linear Zeeman shifts of order 10 MHz are reduced to form a linewidth of around 1 Hz. We estimate a two-order-of-magnitude reduction in averaging time compared to state-of-the art single ion frequency references, assuming a probe laser fractional instability of 10 − 15 . Furthermore, a statistical uncertainty reaching 2.9 × 10−16 in 1 s is estimated for a cascaded clock scheme in which the dynamically decoupled Coulomb crystal clock stabilizes the interrogation laser for an 27 Al + clock.
Optical clocks serve as the benchmark devices for the next-generation definition of the second and have significant applications in testing the theories beyong the standard models, dark matter research, and related fields.The ytterbium ion optical clock, featuring two clock transition lines, is among the most precise optical clocks with the lowest uncertainties.The National Institute of Metrology, China (NIM), initiated research on ytterbium ion optical clocks in 2021.Based on an end-cap ion trap, a vacuum system has been established.A 370 nm thirdharmonic fiber laser, along with 760 nm and 935 nm DFB lasers, ensures a stable operation of the optical system.To date, both the electric quadrupole and electric octupole clock transitions have been observed.A 2.8 Hz linewidth of the electric octupole transition has been achieved, with a stability of 1.7E-15 τ -1/2 after closed-loop locking.The uncertainties due to AC Starks shift from clock laser and second-order Doppler shifts are being evaluated, with an expected total uncertainty below 5E-18.
The 435 mum171Yb+transition is a good candidate for an atomic clock based on an optical transition. We have stored single171Yb ions for several months in RF traps. The ions are cooled, repumped and the clock transition is interrogated by (frequency-doubled) diode lasers. The interrogation laser linewidth was 30 Hz determining the resolvable linewidth of the Yb+transition interrogated. The absolute frequency of this transition was measured using an optical comb generator, self referenced by broadening the spectrum to above one octave, with respect to a Cs fountain clock. Of all systematic frequency shifts to which this transition is subject an estimate indicates that the electric quadruple shift appears is the largest. To obtain a magnitude of the quadruple shift (and the quadruple moment) the clock frequencies of two independently stored and cooled171Yb ions were compared while varying the static electric field in one trap. The measured frequency shift amounting to ~1 Hz/V. This result would seem to permit clocks with much higher accuracy than the clocks based on microwave transition, particularly if the technique of aligning the ions with respect to the electric field were applicable. Anticipating even more precise clocks, we are presently investigating a blue nuclear transition in229Th. Such a nuclear transition should be even better shielded from environmental influences than transitions in the electron shell. This nuclear transition has not yet been directly optically observed. We are presently investigating the luminescence after incoherent broad band optical excitation. The triply ionized223Th is then a suitable system for trapped single ion spectroscopy. The cooling transition lies conveniently in the near infrared and the nuclear clock transition can be read out by nuclear/electron shell double resonance