Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2005.14687 · Physical Review Letters

Coherent Suppression of Tensor Frequency Shifts through Magnetic Field Rotation

R. Lange, Nils Huntemann, Christian Sanner, H. Shao, B. Lipphardt, Chr. Tamm, E. Peik

Published Sep 28, 2020• 19 citations
arXivHTMLPDF

Abstract

We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to the electric quadrupole interaction, we experimentally demonstrate suppression by more than two orders of magnitude for the ^{2}S_{1/2}→^{2}D_{3/2} transition of a single trapped ^{171}Yb^{+} ion. The scheme provides particular advantages in the case of the ^{171}Yb^{+} ^{2}S_{1/2}→^{2}F_{7/2} electric octupole (E3) transition. For an improved estimate of the residual quadrupole shift for this transition, we measure the excited state electric quadrupole moments Θ(^{2}D_{3/2})=1.95(1)ea_{0}^{2} and Θ(^{2}F_{7/2})=-0.0297(5)ea_{0}^{2} with e the elementary charge and a_{0} the Bohr radius, improving the measurement uncertainties by one order of magnitude.

DOI
10.1103/physrevlett.125.143201

Related papers

Evaluation of the electric quadrupole shift in the ytterbium single-ion optical clock

Chao-Wei Wang, Shao-Yang Dai, Ya-Ni Zuo +4 more

Abstract Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.

Chinese Physics B•Apr 17, 2026•0 citations

Multi-ion Frequency Reference Using Dynamical Decoupling

Lennart Pelzer, Kai Dietze, V. J. Martínez-Lahuerta +6 more

We present the experimental realization of a continuous dynamical decoupling scheme which suppresses leading frequency shifts in a multi-ion frequency reference based on ^{40}Ca^{+}. By near-resonant magnetic coupling of the ^{2}S_{1/2} and ^{2}D_{5/2} Zeeman sublevels using radio-frequency dressing fields, engineered transitions with reduced sensitivity to magnetic-field fluctuations are obtained. A second stage detuned dressing field reduces the influence of amplitude noise in the first stage driving fields and decreases 2nd-rank tensor shifts, such as the electric quadrupole shift. Suppression of the quadratic dependence of the quadrupole shift to 3(2) mHz/μm^{2} and coherence times of 290(20) ms on the optical transition are demonstrated even within a laboratory environment with significant magnetic field noise. Besides removing inhomogeneous line shifts in multi-ion clocks, the demonstrated dynamical decoupling technique may find applications in quantum computing and simulation with trapped ions by a tailored design of decoherence-free subspaces.

Physical Review Letters•Jul 17, 2024•11 citations

Multi-ion Frequency Reference Using Dynamical Decoupling

Pelzer, Lennart, Dietze, Kai, Martínez-Lahuerta, Víctor José +6 more

We present the experimental realization of a continuous dynamical decoupling scheme which suppresses leading frequency shifts in a multi-ion frequency reference based on 40Caþ. By near-resonant magnetic coupling of the 2S1=2 and 2D5=2 Zeeman sublevels using radio-frequency dressing fields, engineered transitions with reduced sensitivity to magnetic-field fluctuations are obtained. A second stage detuned dressing field reduces the influence of amplitude noise in the first stage driving fields and decreases 2nd-rank tensor shifts, such as the electric quadrupole shift. Suppression of the quadratic dependence of the quadrupole shift to 3ð2Þ mHz=μm2 and coherence times of 290(20) ms on the optical transition are demonstrated even within a laboratory environment with significant magnetic field noise. Besides removing inhomogeneous line shifts in multi-ion clocks, the demonstrated dynamical decoupling technique may find applications in quantum computing and simulation with trapped ions by a tailored design of decoherence-free subspaces.

•Jan 1, 2024•0 citations

Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty

Nils Huntemann, Christian Sanner, B. Lipphardt +2 more

We experimentally investigate an optical frequency standard based on the (2)S1/2(F=0)→(2)F7/2(F=3) electric octupole (E3) transition of a single trapped (171)Yb+ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy, which reduces the related relative frequency uncertainty to 1.1×10(-18). To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the E3 transition as 0.888(16)×10(-40) J m(2)/V(2) and a dynamic correction η(300 K)=-0.0015(7). This reduces the uncertainty due to thermal radiation to 1.8×10(-18). The residual motion of the ion yields the largest contribution (2.1×10(-18)) to the total systematic relative uncertainty of the clock of 3.2×10(-18).

arXiv:1602.03908•Physical Review Letters•Feb 8, 2016•677 citations

Nuclear Spin Quenching of the S 2 1 / 2 → F 2 7 / 2 Electric Octupole Transition in Yb + 173

Jialiang Yu, Anand Prakash, Clara Zyskind +4 more

We report the coherent excitation of the highly forbidden ^{2}S_{1/2}→^{2}F_{7/2} clock transition in the odd isotope ^{173}Yb^{+} with nuclear spin I=5/2, and reveal the hyperfine-state-dependent, nuclear-spin-induced quenching of this transition. The inferred lifetime of the F_{e}=4 hyperfine state is one order of magnitude shorter than the unperturbed ^{2}F_{7/2} clock state of ^{171}Yb^{+}. This reduced lifetime lowers the required optical power for coherent excitation of the clock transition, thereby reducing the ac Stark shift caused by the clock laser. Using a three-ion Coulomb crystal, we experimentally demonstrate an approximately twentyfold suppression of the ac Stark shift, a critical improvement for the scalability of future multi-ion Yb^{+} clocks. Furthermore, we report the |^{2}S_{1/2},F_{g}=3⟩→|^{2}F_{7/2},F_{e}=6⟩ unquenched reference transition frequency as 642.11917656354(43) THz, along with the measured hyperfine splitting and calculated quadratic Zeeman sensitivities of the ^{2}F_{7/2} clock state. Our results pave the way toward multi-ion optical clocks and quantum computers based on ^{173}Yb^{+}.

arXiv:2512.05872•Physical Review Letters•Dec 15, 2025•1 citation

High-Accuracy Optical Clock Based on the Octupole Transition in Yb+171

Nils Huntemann, Maksim V. Okhapkin, B. Lipphardt +3 more

We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.

arXiv:1111.2446•Physical Review Letters•Feb 29, 2012•241 citations
We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to the electric quadrupole interaction, we experimentally demonstrate suppression by more than two orders of magnitude for the ^{2}S_{1/2}→^{2}D_{3/2} transition of a single trapped ^{171}Yb^{+} ion. The scheme provides particular advantages in the case of the ^{171}Yb^{+} ^{2}S_{1/2}→^{2}F_{7/2} electric octupole (E3) transition. For an improved estimate of the residual quadrupole shift for this transition, we measure the excited state electric quadrupole moments Θ(^{2}D_{3/2})=1.95(1)ea_{0}^{2} and Θ(^{2}F_{7/2})=-0.0297(5)ea_{0}^{2} with e the elementary charge and a_{0} the Bohr radius, improving the measurement uncertainties by one order of magnitude.
Abstract Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.
We present the experimental realization of a continuous dynamical decoupling scheme which suppresses leading frequency shifts in a multi-ion frequency reference based on ^{40}Ca^{+}. By near-resonant magnetic coupling of the ^{2}S_{1/2} and ^{2}D_{5/2} Zeeman sublevels using radio-frequency dressing fields, engineered transitions with reduced sensitivity to magnetic-field fluctuations are obtained. A second stage detuned dressing field reduces the influence of amplitude noise in the first stage driving fields and decreases 2nd-rank tensor shifts, such as the electric quadrupole shift. Suppression of the quadratic dependence of the quadrupole shift to 3(2) mHz/μm^{2} and coherence times of 290(20) ms on the optical transition are demonstrated even within a laboratory environment with significant magnetic field noise. Besides removing inhomogeneous line shifts in multi-ion clocks, the demonstrated dynamical decoupling technique may find applications in quantum computing and simulation with trapped ions by a tailored design of decoherence-free subspaces.
We present the experimental realization of a continuous dynamical decoupling scheme which suppresses leading frequency shifts in a multi-ion frequency reference based on 40Caþ. By near-resonant magnetic coupling of the 2S1=2 and 2D5=2 Zeeman sublevels using radio-frequency dressing fields, engineered transitions with reduced sensitivity to magnetic-field fluctuations are obtained. A second stage detuned dressing field reduces the influence of amplitude noise in the first stage driving fields and decreases 2nd-rank tensor shifts, such as the electric quadrupole shift. Suppression of the quadratic dependence of the quadrupole shift to 3ð2Þ mHz=μm2 and coherence times of 290(20) ms on the optical transition are demonstrated even within a laboratory environment with significant magnetic field noise. Besides removing inhomogeneous line shifts in multi-ion clocks, the demonstrated dynamical decoupling technique may find applications in quantum computing and simulation with trapped ions by a tailored design of decoherence-free subspaces.
We experimentally investigate an optical frequency standard based on the (2)S1/2(F=0)→(2)F7/2(F=3) electric octupole (E3) transition of a single trapped (171)Yb+ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy, which reduces the related relative frequency uncertainty to 1.1×10(-18). To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the E3 transition as 0.888(16)×10(-40) J m(2)/V(2) and a dynamic correction η(300 K)=-0.0015(7). This reduces the uncertainty due to thermal radiation to 1.8×10(-18). The residual motion of the ion yields the largest contribution (2.1×10(-18)) to the total systematic relative uncertainty of the clock of 3.2×10(-18).
We report the coherent excitation of the highly forbidden ^{2}S_{1/2}→^{2}F_{7/2} clock transition in the odd isotope ^{173}Yb^{+} with nuclear spin I=5/2, and reveal the hyperfine-state-dependent, nuclear-spin-induced quenching of this transition. The inferred lifetime of the F_{e}=4 hyperfine state is one order of magnitude shorter than the unperturbed ^{2}F_{7/2} clock state of ^{171}Yb^{+}. This reduced lifetime lowers the required optical power for coherent excitation of the clock transition, thereby reducing the ac Stark shift caused by the clock laser. Using a three-ion Coulomb crystal, we experimentally demonstrate an approximately twentyfold suppression of the ac Stark shift, a critical improvement for the scalability of future multi-ion Yb^{+} clocks. Furthermore, we report the |^{2}S_{1/2},F_{g}=3⟩→|^{2}F_{7/2},F_{e}=6⟩ unquenched reference transition frequency as 642.11917656354(43) THz, along with the measured hyperfine splitting and calculated quadratic Zeeman sensitivities of the ^{2}F_{7/2} clock state. Our results pave the way toward multi-ion optical clocks and quantum computers based on ^{173}Yb^{+}.
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.