Chinese Physics B
Evaluation of the electric quadrupole shift in the ytterbium single-ion optical clock
Chao-Wei Wang, Shao-Yang Dai, Ya-Ni Zuo, Kun Liu, Wen-Bo Zhao, Yue-xiang Han, Fang Fang
Abstract
Abstract Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.