Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1503.07941 · Physical Review Letters

Frequency Ratio of Hg 199 and Sr 87 Optical Lattice Clocks beyond the SI Limit

K. Yamanaka, Noriaki Ohmae, Ichiro Ushijima, Masao Takamoto, Hidetoshi Katori

Published Jun 10, 2015• 106 citations
arXivHTMLPDF

Abstract

We report on a frequency ratio measurement of a $^{199}\mathrm{Hg}$-based optical lattice clock referencing a $^{87}\mathrm{Sr}$-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ for the Hg clock. The frequency ratio is measured to be ${\ensuremath{\nu}}_{\mathrm{Hg}}/{\ensuremath{\nu}}_{\mathrm{Sr}}=2.629\text{ }314\text{ }209\text{ }898\text{ }909\text{ }60(22)$ with a fractional uncertainty of $8.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$, which is smaller than the uncertainty of the realization of the International System of Units (SI) second, i.e., the SI limit.

DOI
10.1103/physrevlett.114.230801

Related papers

Atomic clock frequency ratios with fractional uncertainty $\leq 3.2 \times 10^{-18}$

Alexander Aeppli, Willa J. Arthur-Dworschack, Kyle Beloy +24 more

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in $^{87}$Sr ratios at approximately $1\times10^{-16}$ and the Al$^+$/Yb ratio at $1.6\times10^{-17}$ in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of $1.3 \times 10^{-16}$ at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.

physics.atom-phCross-listedarXiv:2512.21428•Physical Review Letters•Dec 26, 2025•11 citations

An Al$^+$ clock with $1.6\times10^{-18}$ systematic uncertainty and its frequency ratios

Fabian Dawel, Johannes Krämer, D. Drapier +15 more

Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an $^{27}\mathrm{Al}^+$ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a $^{87}$Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is $1.6\times10^{-18}$, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be $ν_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,$Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be $ν_{\mathrm{Al}^+}/ν_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)$, limited by the accuracy of the Sr clock. This ratio differs by $8.6σ$ and $1.2σ$ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.

arXiv:2606.23151•Jun 22, 2026•3 citations

Evaluation of Lattice Light Shift at Low 10−19 Uncertainty for a Shallow Lattice Sr Optical Clock

Kyungtae Kim, Alexander Aeppli, Tobias Bothwell +1 more

A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5×10^{-19}.

arXiv:2210.16374•Physical Review Letters•Mar 15, 2023•72 citations

Clock with 8 × 10 − 19 Systematic Uncertainty

Alexander Aeppli, Kyungtae Kim, William Warfield +2 more

We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.

arXiv:2403.10664•Physical Review Letters•Jul 10, 2024•246 citations

Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$

Manoj Das, Hidetoshi Katori, Ichiro Ushijima +2 more

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systeme International) second that refers to Cs microwave clocks with fractional uncertainties at $10^{-16}$. Recent revolutionary progress of optical clocks aims to achieve $1\times 10^{-18}$ uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with $^{87}$Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for $N \sim 1,000$ atoms allows investigation of the uncertainties at $2\times 10^{-18}$ in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within $(-1.1\pm 1.6)\times 10^{-18}$. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.

•May 16, 2014•10 citations

Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$

Ichiro Ushijima, Masao Takamoto, Das, Manoj +2 more

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systéme International) second that refers to Cs microwave clocks with fractional uncertainties at $10^{-16}$. Recent revolutionary progress of optical clocks aims to achieve $1\times 10^{-18}$ uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with $^{87}$Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for $N \sim 1,000$ atoms allows investigation of the uncertainties at $2\times 10^{-18}$ in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within $(-1.1\pm 1.6)\times 10^{-18}$. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.

arXiv:1405.4071•May 16, 2014•25 citations
We report on a frequency ratio measurement of a 199Hg^{199}\mathrm{Hg}199Hg-based optical lattice clock referencing a 87Sr^{87}\mathrm{Sr}87Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of 7.2\ifmmode×\else\texttimes\fi10\ensuremath−177.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}7.2\ifmmode×\else\texttimes\fi10\ensuremath−17 for the Hg clock. The frequency ratio is measured to be \ensuremathνHg/\ensuremathνSr=2.629 314 209 898 909 60(22){\ensuremath{\nu}}_{\mathrm{Hg}}/{\ensuremath{\nu}}_{\mathrm{Sr}}=2.629\text{ }314\text{ }209\text{ }898\text{ }909\text{ }60(22)\ensuremathνHg​/\ensuremathνSr​=2.629 314 209 898 909 60(22) with a fractional uncertainty of 8.4\ifmmode×\else\texttimes\fi10\ensuremath−178.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}8.4\ifmmode×\else\texttimes\fi10\ensuremath−17, which is smaller than the uncertainty of the realization of the International System of Units (SI) second, i.e., the SI limit.
Atomic clock frequency ratios with fractional uncertainty ≤3.2×10−18\leq 3.2 \times 10^{-18}≤3.2×10−18
We report high-precision frequency ratio measurements between optical atomic clocks based on 27^{27}27Al+^++, 171^{171}171Yb, and 87^{87}87Sr. With total fractional uncertainties at or below 3.2×10−183.2 \times 10^{-18}3.2×10−18, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in 87^{87}87Sr ratios at approximately 1×10−161\times10^{-16}1×10−16 and the Al+^++/Yb ratio at 1.6×10−171.6\times10^{-17}1.6×10−17 in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of 1.3×10−161.3 \times 10^{-16}1.3×10−16 at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.
An Al+^++ clock with 1.6×10−181.6\times10^{-18}1.6×10−18 systematic uncertainty and its frequency ratios
Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an 27Al+^{27}\mathrm{Al}^+27Al+ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a 87^{87}87Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is 1.6×10−181.6\times10^{-18}1.6×10−18, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be νAl+=1121015393207859.19(24) ν_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,νAl+​=1121015393207859.19(24)Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be νAl+/ν87Sr=2.611701431781462668(36)ν_{\mathrm{Al}^+}/ν_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)νAl+​/ν87Sr​=2.611701431781462668(36), limited by the accuracy of the Sr clock. This ratio differs by 8.6σ8.6σ8.6σ and 1.2σ1.2σ1.2σ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.
A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5×10^{-19}.
We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.
Cryogenic optical lattice clocks with a relative frequency difference of 1×10−181\times 10^{-18}1×10−18
Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systeme International) second that refers to Cs microwave clocks with fractional uncertainties at 10−1610^{-16}10−16. Recent revolutionary progress of optical clocks aims to achieve 1×10−181\times 10^{-18}1×10−18 uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with 87^{87}87Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for N∼1,000N \sim 1,000N∼1,000 atoms allows investigation of the uncertainties at 2×10−182\times 10^{-18}2×10−18 in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within (−1.1±1.6)×10−18(-1.1\pm 1.6)\times 10^{-18}(−1.1±1.6)×10−18. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.
Cryogenic optical lattice clocks with a relative frequency difference of 1×10−181\times 10^{-18}1×10−18
Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systéme International) second that refers to Cs microwave clocks with fractional uncertainties at 10−1610^{-16}10−16. Recent revolutionary progress of optical clocks aims to achieve 1×10−181\times 10^{-18}1×10−18 uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with 87^{87}87Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for N∼1,000N \sim 1,000N∼1,000 atoms allows investigation of the uncertainties at 2×10−182\times 10^{-18}2×10−18 in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within (−1.1±1.6)×10−18(-1.1\pm 1.6)\times 10^{-18}(−1.1±1.6)×10−18. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.