arXiv:1405.4071

Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$

Ichiro Ushijima, Masao Takamoto, Das, Manoj, Ohkubo, Takuya, Hidetoshi Katori

Published May 16, 2014• 0 citations
arXivHTMLPDF

Abstract

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systéme International) second that refers to Cs microwave clocks with fractional uncertainties at $10^{-16}$. Recent revolutionary progress of optical clocks aims to achieve $1\times 10^{-18}$ uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with $^{87}$Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for $N \sim 1,000$ atoms allows investigation of the uncertainties at $2\times 10^{-18}$ in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within $(-1.1\pm 1.6)\times 10^{-18}$. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.

DOI
10.48550/arxiv.1405.4071

Related papers

Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$

Manoj Das, Hidetoshi Katori, Ichiro Ushijima +2 more

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systeme International) second that refers to Cs microwave clocks with fractional uncertainties at $10^{-16}$. Recent revolutionary progress of optical clocks aims to achieve $1\times 10^{-18}$ uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with $^{87}$Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for $N \sim 1,000$ atoms allows investigation of the uncertainties at $2\times 10^{-18}$ in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within $(-1.1\pm 1.6)\times 10^{-18}$. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.

•May 16, 2014•7 citations

A clock network for geodesy and fundamental science

Christian Lisdat, Gesine Grosche, Nicolas Quintin +32 more

Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.

arXiv:1511.07735•Nature Communications•Aug 9, 2016•460 citations

Development of an Apparatus for a Strontium Optical Lattice Optical Frequency Standard

Ian R. Hill

Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.

•Jun 1, 2012•3 citations

Tackling the blackbody shift in a strontium optical lattice clock

Thomas Middelmann, Christian Lisdat, Stephan Falke +3 more

A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock transition and, secondly, by interrogating the atoms in a cryogenic environment. Both approaches rely on transporting ultracold atoms over several cm within a probe cycle. We evaluate this approach of mechanically moving the optical lattice and conclude that it is feasible to transport the atoms over 50 mm within 300 ms. With this transport a dc Stark shift measurement will allow to reduce the contribution of the blackbody radiation to the fractional uncertainty below 2 * 10^-17 at room temperature by improving the shift coefficient known only from atomic structure calculations up to now. We propose a cryogenic environment at 77 K that will reduce this contribution to few parts in 10^-18.

arXiv:1009.2017•Sep 10, 2010•2 citations

87Sr optical lattice clocks at JILA

Michael J. Martin, Matthew D. Swallows, Travis Nicholson +5 more

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations

Atomic clock frequency ratios with fractional uncertainty $\leq 3.2 \times 10^{-18}$

Alexander Aeppli, Willa J. Arthur-Dworschack, Kyle Beloy +24 more

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in $^{87}$Sr ratios at approximately $1\times10^{-16}$ and the Al$^+$/Yb ratio at $1.6\times10^{-17}$ in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of $1.3 \times 10^{-16}$ at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.

physics.atom-phCross-listedarXiv:2512.21428•Dec 26, 2025
Cryogenic optical lattice clocks with a relative frequency difference of 1×10−181\times 10^{-18}1×10−18
Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systéme International) second that refers to Cs microwave clocks with fractional uncertainties at 10−1610^{-16}10−16. Recent revolutionary progress of optical clocks aims to achieve 1×10−181\times 10^{-18}1×10−18 uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with 87^{87}87Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for N∼1,000N \sim 1,000N∼1,000 atoms allows investigation of the uncertainties at 2×10−182\times 10^{-18}2×10−18 in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within (−1.1±1.6)×10−18(-1.1\pm 1.6)\times 10^{-18}(−1.1±1.6)×10−18. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.
Cryogenic optical lattice clocks with a relative frequency difference of 1×10−181\times 10^{-18}1×10−18
Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systeme International) second that refers to Cs microwave clocks with fractional uncertainties at 10−1610^{-16}10−16. Recent revolutionary progress of optical clocks aims to achieve 1×10−181\times 10^{-18}1×10−18 uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with 87^{87}87Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for N∼1,000N \sim 1,000N∼1,000 atoms allows investigation of the uncertainties at 2×10−182\times 10^{-18}2×10−18 in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within (−1.1±1.6)×10−18(-1.1\pm 1.6)\times 10^{-18}(−1.1±1.6)×10−18. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.
A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock transition and, secondly, by interrogating the atoms in a cryogenic environment. Both approaches rely on transporting ultracold atoms over several cm within a probe cycle. We evaluate this approach of mechanically moving the optical lattice and conclude that it is feasible to transport the atoms over 50 mm within 300 ms. With this transport a dc Stark shift measurement will allow to reduce the contribution of the blackbody radiation to the fractional uncertainty below 2 * 10^-17 at room temperature by improving the shift coefficient known only from atomic structure calculations up to now. We propose a cryogenic environment at 77 K that will reduce this contribution to few parts in 10^-18.
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.
Atomic clock frequency ratios with fractional uncertainty ≤3.2×10−18\leq 3.2 \times 10^{-18}≤3.2×10−18
We report high-precision frequency ratio measurements between optical atomic clocks based on 27^{27}27Al+^++, 171^{171}171Yb, and 87^{87}87Sr. With total fractional uncertainties at or below 3.2×10−183.2 \times 10^{-18}3.2×10−18, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in 87^{87}87Sr ratios at approximately 1×10−161\times10^{-16}1×10−16 and the Al+^++/Yb ratio at 1.6×10−171.6\times10^{-17}1.6×10−17 in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of 1.3×10−161.3 \times 10^{-16}1.3×10−16 at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.