Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2210.16374 · Physical Review Letters

Evaluation of Lattice Light Shift at Low 10−19 Uncertainty for a Shallow Lattice Sr Optical Clock

Kyungtae Kim, Alexander Aeppli, Tobias Bothwell, Jun Ye

Published Mar 15, 2023• 63 citations
arXivHTMLPDF

Abstract

A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5×10^{-19}.

DOI
10.1103/physrevlett.130.113203

Related papers

Strategies for reducing the light shift in atomic clocks

Hidetoshi Katori, Vitalii D Ovsiannikov, S. I. Marmo +1 more

Recent progress in optical lattice clocks requires unprecedented precision in controlling systematic uncertainties at the ${10}^{\ensuremath{-}18}$ level. Tuning of nonlinear light shifts is shown to reduce lattice-induced clock shift for a wide range of lattice intensity. Based on theoretical multipolar, nonlinear, anharmonic, and higher-order light shifts, we numerically demonstrate possible strategies for Sr, Yb, and Hg clocks to achieve lattice-induced systematic uncertainty below $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$.

arXiv:1503.07633•Physical Review A•May 14, 2015•74 citations

Clock with 8 × 10 − 19 Systematic Uncertainty

Alexander Aeppli, Kyungtae Kim, William Warfield +2 more

We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.

arXiv:2403.10664•Physical Review Letters•Jul 10, 2024•211 citations

Frequency Ratio of Hg 199 and Sr 87 Optical Lattice Clocks beyond the SI Limit

K. Yamanaka, Noriaki Ohmae, Ichiro Ushijima +2 more

We report on a frequency ratio measurement of a $^{199}\mathrm{Hg}$-based optical lattice clock referencing a $^{87}\mathrm{Sr}$-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ for the Hg clock. The frequency ratio is measured to be ${\ensuremath{\nu}}_{\mathrm{Hg}}/{\ensuremath{\nu}}_{\mathrm{Sr}}=2.629\text{ }314\text{ }209\text{ }898\text{ }909\text{ }60(22)$ with a fractional uncertainty of $8.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$, which is smaller than the uncertainty of the realization of the International System of Units (SI) second, i.e., the SI limit.

Physical Review Letters•Jun 10, 2015•104 citations

Higher-order shifts of a clock frequency in Sr, Yb and Hg atoms trapped in an optical lattice

Vitalii D Ovsiannikov, Vitalii G Pal'chikov, Hidetoshi Katori

The recent progress in designing optical frequency standards with an uncertainty at a level of 10-17-10-18 requires unprecedented accuracy in estimating the role of higher-order uncertainties of optical clocks. In this paper, we systematically evaluate the multipole, nonlinear, anharmonic contributions to uncertainty of the optical-lattice-based clocks of alkaline-earth-like-atoms Sr, Yb and Hg.

European Frequency and Time Forum•Jun 1, 2014•0 citations

Operating a 87 Sr optical lattice clock with high precision and at high density

Matthew D. Swallows, Michael J. Martin, Michael Bishof +5 more

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-(16) fractional frequency level. An upgraded laser system has recently been constructed in our lab which may allow the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. To take full advantage of these improvements, it will be necessary to operate a lattice clock with a large number of atoms, and systematic frequency shifts resulting from atomic interactions will become increasingly important. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms and describe a novel method by which such systematic effects can be suppressed.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2012•46 citations

Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ

Takumi Kobayashi, Daisuke Akamatsu, Yusuke Hisai +6 more

We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

arXiv:1901.00954•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Sep 18, 2018•26 citations
A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5×10^{-19}.
Recent progress in optical lattice clocks requires unprecedented precision in controlling systematic uncertainties at the ${10}^{\ensuremath{-}18}$ level. Tuning of nonlinear light shifts is shown to reduce lattice-induced clock shift for a wide range of lattice intensity. Based on theoretical multipolar, nonlinear, anharmonic, and higher-order light shifts, we numerically demonstrate possible strategies for Sr, Yb, and Hg clocks to achieve lattice-induced systematic uncertainty below $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$.
We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.
We report on a frequency ratio measurement of a 199Hg^{199}\mathrm{Hg}199Hg-based optical lattice clock referencing a 87Sr^{87}\mathrm{Sr}87Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ for the Hg clock. The frequency ratio is measured to be ${\ensuremath{\nu}}_{\mathrm{Hg}}/{\ensuremath{\nu}}_{\mathrm{Sr}}=2.629\text{ }314\text{ }209\text{ }898\text{ }909\text{ }60(22)$ with a fractional uncertainty of $8.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$, which is smaller than the uncertainty of the realization of the International System of Units (SI) second, i.e., the SI limit.
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-(16) fractional frequency level. An upgraded laser system has recently been constructed in our lab which may allow the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. To take full advantage of these improvements, it will be necessary to operate a lattice clock with a large number of atoms, and systematic frequency shifts resulting from atomic interactions will become increasingly important. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms and describe a novel method by which such systematic effects can be suppressed.
We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.