Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1401.4186

The escape physics of single shot measurement of flux qubit with dcSQUID

Mao-Chuang Yeh, Anthony J. Leggett

Published Jan 16, 2014• 1 citation
arXivHTMLPDF

Abstract

In most experiments on flux qubits,the "measurement" is performed by coupling the system to a dc SQUID and recording the distribution of switching currents for the latter;this measurement protocol is very far from the classic von Neumann ("projective") scheme,in that very little information is obtained from a single run,rather one has to repeat the experiment tens of thosands of times to extract anything useful.Here, concentrating on the equlibrium behavior of the flux qubit,we carry out an analytic calculation of the dc-SQUID switching current distribution as a function of external bias flux on the qubit,and compare our predictions with the data from experiments conducted at Delft and NTT.

DOI
10.48550/arxiv.1401.4186

Related papers

A theoretical analysis of flux-qubit measurements with a dc-SQUID

Nakano, H., Hirotaka Tanaka, Shiro Saito +3 more

The readout process of a superconducting flux-qubit is theoretically analyzed in terms of the quantum dynamics of a qubit-SQUID coupled system during measurement. The quantity directly observed by the measurement is the switching current (Isw) of the dc-SQUID placed around the qubit ring. In order to clarify the relation between the Isw and the qubit state, we calculated the time evolution of the density operator of the qubit-SQUID system while increasing the SQUID bias current until switching events occur and obtained the switching current distributions. This clarifies what information of the qubit is obtained by a dc-SQUID switching current measurement under specific conditions, for example, when the qubit eigenstate is a superposition of two different flux states.

arXiv:cond-mat/0406622•Jun 25, 2004•2 citations

Single-Shot Readout of Macroscopic Quantum Superposition State in a Superconducting Flux Qubit

Hirotaka Tanaka, Shiro Saito, Hayato Nakano +3 more

Single-shot readout experiments were performed on the two lowest-energy states of a superconducting qubit with three Josephson junctions embedded in a superconducting loop. We measured the qubit state via switching current Isw of a current-biased dc-SQUID, a quantum detector surrounding the qubit loop. The qubit signals were measured in a small Isw regime of the SQUID, typically less than 100 nA, where the Isw distribution is particularly narrow. The obtained single-shot data indicate that the qubit state is readout, through the flux generated by the qubit persistent-current, as energy eigenstates rather than current eigenstates.

arXiv:cond-mat/0407299•Jul 12, 2004•8 citations

Relaxation and Dephasing in a Flux-qubit

Patrice Bertet, I. Chiorescu, Guido Burkard +4 more

We report detailed measurements of the relaxation and dephasing time in a flux-qubit measured by a switching DC SQUID. We studied their dependence on the two important circuit bias parameters: the externally applied magnetic flux and the bias current through the SQUID in two samples. We demonstrate two complementary strategies to protect the qubit from these decoherence sources. One consists in biasing the qubit so that its resonance frequency is stationary with respect to the control parameters ({\it optimal point}) ; the second consists in {\it decoupling} the qubit from current noise by chosing a proper bias current through the SQUID. At the decoupled optimal point, we measured long spin-echo decay times of up to $4 μs$.

arXiv:cond-mat/0412485•Dec 17, 2004•14 citations

Fast High-Fidelity Measurements of the Ground and Excited States of a dc-SQUID Phase Qubit

Tauno Palomaki, S. K. Dutta, Rupert Lewis +8 more

We have investigated the fidelity and speed of single-shot current-pulse measurements of the three lowest energy states of the dc SQUID phase qubit. We apply a short (2ns) current pulse to one junction of a Nb/AlOx/Nb SQUID that is in the zero voltage state at 25 mK and measure if the system switches to the finite voltage state. By plotting the switching rate versus pulse size we can determine average occupancy of the levels down to 0.01%, quantify small levels of leakage, and find the optimum pulse condition for single-shot measurements. Our best error rate is 3% with a measurement fidelity of 94%. By monitoring the escape rate during the pulse, the pulse current in the junction can be found to better than 10 nA on a 0.1 ns time scale. Theoretical analysis of the system reveals switching curves that are in good agreement with the data, as well as predictions that the ultimate single-shot error rate for this technique can reach 0.4% and the fidelity 99.2%.

arXiv:cond-mat/0608399•Aug 17, 2006•2 citations

Efficiency of underdamped dc SQUIDs as readout devices for flux qubits

Shaoxiong Li, Yang Yu, Wei Qiu +2 more

The flux state quantum bit (qubit) is promising for a solid state implementation of scalable quantum computing. The simplest flux state qubit consists of an rf SQUID with two fluxoid states, which can be readout with a dc SQUID - the most sensitive magnetic flux detector. Efficient readout with less back-action is desirable for quantum computing. In this work, we report measurements of the switching flux and switching current distributions of under damped dc SQUIDs. The data show that single shot readout of flux qubit with very high efficiency (>99%) can be realized using underdamped hysteretic dc SQUIDs.

IEEE Transactions on Applied Superconductivity•Jun 1, 2003•2 citations

Quantum state detection of a superconducting flux qubit using a dc-SQUID in the inductive mode

Adrian Lupaşcu, C. J. P. M. Harmans, Johan E. Mooij

We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.

arXiv:cond-mat/0410730•Physical Review B•May 13, 2005•25 citations
In most experiments on flux qubits,the "measurement" is performed by coupling the system to a dc SQUID and recording the distribution of switching currents for the latter;this measurement protocol is very far from the classic von Neumann ("projective") scheme,in that very little information is obtained from a single run,rather one has to repeat the experiment tens of thosands of times to extract anything useful.Here, concentrating on the equlibrium behavior of the flux qubit,we carry out an analytic calculation of the dc-SQUID switching current distribution as a function of external bias flux on the qubit,and compare our predictions with the data from experiments conducted at Delft and NTT.
The readout process of a superconducting flux-qubit is theoretically analyzed in terms of the quantum dynamics of a qubit-SQUID coupled system during measurement. The quantity directly observed by the measurement is the switching current (Isw) of the dc-SQUID placed around the qubit ring. In order to clarify the relation between the Isw and the qubit state, we calculated the time evolution of the density operator of the qubit-SQUID system while increasing the SQUID bias current until switching events occur and obtained the switching current distributions. This clarifies what information of the qubit is obtained by a dc-SQUID switching current measurement under specific conditions, for example, when the qubit eigenstate is a superposition of two different flux states.
Single-shot readout experiments were performed on the two lowest-energy states of a superconducting qubit with three Josephson junctions embedded in a superconducting loop. We measured the qubit state via switching current Isw of a current-biased dc-SQUID, a quantum detector surrounding the qubit loop. The qubit signals were measured in a small Isw regime of the SQUID, typically less than 100 nA, where the Isw distribution is particularly narrow. The obtained single-shot data indicate that the qubit state is readout, through the flux generated by the qubit persistent-current, as energy eigenstates rather than current eigenstates.
We report detailed measurements of the relaxation and dephasing time in a flux-qubit measured by a switching DC SQUID. We studied their dependence on the two important circuit bias parameters: the externally applied magnetic flux and the bias current through the SQUID in two samples. We demonstrate two complementary strategies to protect the qubit from these decoherence sources. One consists in biasing the qubit so that its resonance frequency is stationary with respect to the control parameters ({\it optimal point}) ; the second consists in {\it decoupling} the qubit from current noise by chosing a proper bias current through the SQUID. At the decoupled optimal point, we measured long spin-echo decay times of up to 4μs4 μs4μs.
We have investigated the fidelity and speed of single-shot current-pulse measurements of the three lowest energy states of the dc SQUID phase qubit. We apply a short (2ns) current pulse to one junction of a Nb/AlOx/Nb SQUID that is in the zero voltage state at 25 mK and measure if the system switches to the finite voltage state. By plotting the switching rate versus pulse size we can determine average occupancy of the levels down to 0.01%, quantify small levels of leakage, and find the optimum pulse condition for single-shot measurements. Our best error rate is 3% with a measurement fidelity of 94%. By monitoring the escape rate during the pulse, the pulse current in the junction can be found to better than 10 nA on a 0.1 ns time scale. Theoretical analysis of the system reveals switching curves that are in good agreement with the data, as well as predictions that the ultimate single-shot error rate for this technique can reach 0.4% and the fidelity 99.2%.
The flux state quantum bit (qubit) is promising for a solid state implementation of scalable quantum computing. The simplest flux state qubit consists of an rf SQUID with two fluxoid states, which can be readout with a dc SQUID - the most sensitive magnetic flux detector. Efficient readout with less back-action is desirable for quantum computing. In this work, we report measurements of the switching flux and switching current distributions of under damped dc SQUIDs. The data show that single shot readout of flux qubit with very high efficiency (>99%) can be realized using underdamped hysteretic dc SQUIDs.
We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.