IEEE Transactions on Applied Superconductivity

Efficiency of underdamped dc SQUIDs as readout devices for flux qubits

Shaoxiong Li, Yang Yu, Wei Qiu, Siyuan Han, Zhen Wang

Published Jun 1, 2003• 2 citations
Publisher

Abstract

The flux state quantum bit (qubit) is promising for a solid state implementation of scalable quantum computing. The simplest flux state qubit consists of an rf SQUID with two fluxoid states, which can be readout with a dc SQUID - the most sensitive magnetic flux detector. Efficient readout with less back-action is desirable for quantum computing. In this work, we report measurements of the switching flux and switching current distributions of under damped dc SQUIDs. The data show that single shot readout of flux qubit with very high efficiency (>99%) can be realized using underdamped hysteretic dc SQUIDs.

DOI
10.1109/tasc.2003.814119

Related papers

Stroboscopic single-shot detection of the flux state in a radio frequency superconducting quantum interference device

C. Cosmelli, F. Sciamanna, Maria Gabriella Castellano +4 more

The flux states of a rf superconducting quantum interference device (SQUID) can be used to investigate macroscopic quantum effects, the most challenging of which is the detection of quantum coherent oscillations, and are promising candidates for the implementation of quantum computing. The use of a proper readout system is of utmost importance for these purposes. In this letter we present experimental evidence of the possibility of using an underdamped, hysteretic dc SQUID to read out stroboscopically the flux states of a rf SQUID, allowing a single shot discrimination with an efficiency of 98%. The devices are all integrated on chip.

Applied Physics Letters•Apr 29, 2002•14 citations

Low-Back-Action RF SQUID Readout for a Josephson Flux Qubit Measurement

V. I. Shnyrkov, Andrii P. Shapovalov, A.A. Kalenyuk +3 more

Superconducting qubits demonstrate good perspectives as scalable blocks for quantum information processing. These systems can be individually readout, addressed, and controlled, making them some of the most attractive thin-film qubits. Quantum measurements should be performed in order to readout the final state of flux qubits. To observe the dynamics of such systems, one requires a fast magnetometer with exceptional sensitivity and low back-action. We address the problem of reducing the back-action of an RF SQUID readout circuit, which may significantly destroy a Josephson flux qubit in the case of the circuits integration. The main sources of such back-action in conventional RF SQUID and DC SQUID circuits are low-ohmic shunting resistors ensuring high damping. The advantage of flux qubits is the presence of an optimal bias point at which, in the first-order approximation, the device is immune to fluctuations in readout and control lines. Nonetheless, even such systems have characteristics limited by a second-order dissipation. The dissipation can be eliminated by using an “ideal parametric readout” based on an RF SQUID acting in non-hysteretic adiabatic mode. In this paper, we propose an RF SQUID in a non-hysteretic regime as a fast, sensitive, and scalable readout system with low back-action for measurements of a single MW photon counter based on a flux qubit.

IEEE International Conference on Electronics and Information Technologies (ELIT)•May 19, 2021•1 citation

Quantum state detection of a superconducting flux qubit using a dc-SQUID in the inductive mode

Adrian Lupaşcu, C. J. P. M. Harmans, Johan E. Mooij

We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.

arXiv:cond-mat/0410730•Physical Review B•May 13, 2005•25 citations

A hysteretic dc SQUID reading the flux states of an rf SQUID

C. Cosmelli, P. Carelli, Maria Gabriella Castellano +3 more

We have realized a hysteretic dc SQUID to measure the flux states of a rf SQUID inductively coupled to the hysteretic dc SQUID. This type of measurement is required whenever is necessary to make a non invasive measure of the state of the rf SQUID. This is the case of measurements of macroscopic quantum coherence or measurements on q-bits systems. With the proposed set up the hysteretic dc SQUID can switch from the superconducting to the normal state depending on the total applied magnetic flux. On this system we measured at 4.2 K the change on the switching probability of the dc SQUID by varying the flux state of the rf SQUID. The experimental results agree very well with the theoretical predictions showing that this device can be used to perform non invasive measurements of the rf SQUID flux state.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•12 citations

Dc SQUID sensitivity for readout of entangled state quantum bits

H Tanaka, Y Sekine, S Saito +1 more

We propose a scheme for entangled state measurement at flux qubits (quantum bits) depending on the sensitivity measurement of a dc SQUID (superconducting quantum interference device). The dc SQUID is used as a flux qubit readout device. The switching current distribution of the dc SQUID is sufficiently narrow to distinguish between two ground states of three Josephson junction qubits with a large mutual inductance between a qubit and the dc SQUID. However, discrimination between two ground states becomes difficult with the smaller mutual inductance that is preferable for qubit coherence. We employed averaging to increase the effective sensitivity. However the averaging smears out the entanglement over two qubits. We found that a Bell-pair measurement can be performed with flux qubits to prove the existence of an entangled state over two qubits. The pre-ensembled measurement scheme, in which our flux qubit readouts work, is preferable to entangled state measurement.

arXiv:cond-mat/0108231•Superconductor Science and Technology•Nov 21, 2001•5 citations

Tracing the characteristics of a flux qubit with a hysteretic dc-superconducting quantum interference device comparator

Maria Gabriella Castellano, F. Chiarello, Roberto Leoni +6 more

A hysteretic dc-superconducting quantum interference device (SQUID) is used to trace the flux characteristic of a tunable rf-SQUID, the basic element for the realization of superconducting flux qubits. This allows important simplifications of circuitry and electronics in developing devices for quantum computing, by eliminating the necessity of more complex magnetometers. A hysteretic dc-SQUID is usually operated as a comparator, distinguishing only which one of two adjacent flux states is occupied by the rf-SQUID. The necessary sensitivity, moreover, is usually reached only at temperatures in the mK range. However, by exploiting the statistical properties of the current–voltage curve in the region where the switching from the zero-voltage state occurs, it is possible to obtain an accurate tracing of the input flux, even at a relatively high temperature (a few Kelvin). In our case, the input signal is given by the internal flux of a tunable rf-SQUID, the building block of a flux qubit.

Journal of Applied Physics•Dec 4, 2003•4 citations
The flux state quantum bit (qubit) is promising for a solid state implementation of scalable quantum computing. The simplest flux state qubit consists of an rf SQUID with two fluxoid states, which can be readout with a dc SQUID - the most sensitive magnetic flux detector. Efficient readout with less back-action is desirable for quantum computing. In this work, we report measurements of the switching flux and switching current distributions of under damped dc SQUIDs. The data show that single shot readout of flux qubit with very high efficiency (>99%) can be realized using underdamped hysteretic dc SQUIDs.
The flux states of a rf superconducting quantum interference device (SQUID) can be used to investigate macroscopic quantum effects, the most challenging of which is the detection of quantum coherent oscillations, and are promising candidates for the implementation of quantum computing. The use of a proper readout system is of utmost importance for these purposes. In this letter we present experimental evidence of the possibility of using an underdamped, hysteretic dc SQUID to read out stroboscopically the flux states of a rf SQUID, allowing a single shot discrimination with an efficiency of 98%. The devices are all integrated on chip.
Superconducting qubits demonstrate good perspectives as scalable blocks for quantum information processing. These systems can be individually readout, addressed, and controlled, making them some of the most attractive thin-film qubits. Quantum measurements should be performed in order to readout the final state of flux qubits. To observe the dynamics of such systems, one requires a fast magnetometer with exceptional sensitivity and low back-action. We address the problem of reducing the back-action of an RF SQUID readout circuit, which may significantly destroy a Josephson flux qubit in the case of the circuits integration. The main sources of such back-action in conventional RF SQUID and DC SQUID circuits are low-ohmic shunting resistors ensuring high damping. The advantage of flux qubits is the presence of an optimal bias point at which, in the first-order approximation, the device is immune to fluctuations in readout and control lines. Nonetheless, even such systems have characteristics limited by a second-order dissipation. The dissipation can be eliminated by using an “ideal parametric readout” based on an RF SQUID acting in non-hysteretic adiabatic mode. In this paper, we propose an RF SQUID in a non-hysteretic regime as a fast, sensitive, and scalable readout system with low back-action for measurements of a single MW photon counter based on a flux qubit.
We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.
We have realized a hysteretic dc SQUID to measure the flux states of a rf SQUID inductively coupled to the hysteretic dc SQUID. This type of measurement is required whenever is necessary to make a non invasive measure of the state of the rf SQUID. This is the case of measurements of macroscopic quantum coherence or measurements on q-bits systems. With the proposed set up the hysteretic dc SQUID can switch from the superconducting to the normal state depending on the total applied magnetic flux. On this system we measured at 4.2 K the change on the switching probability of the dc SQUID by varying the flux state of the rf SQUID. The experimental results agree very well with the theoretical predictions showing that this device can be used to perform non invasive measurements of the rf SQUID flux state.
We propose a scheme for entangled state measurement at flux qubits (quantum bits) depending on the sensitivity measurement of a dc SQUID (superconducting quantum interference device). The dc SQUID is used as a flux qubit readout device. The switching current distribution of the dc SQUID is sufficiently narrow to distinguish between two ground states of three Josephson junction qubits with a large mutual inductance between a qubit and the dc SQUID. However, discrimination between two ground states becomes difficult with the smaller mutual inductance that is preferable for qubit coherence. We employed averaging to increase the effective sensitivity. However the averaging smears out the entanglement over two qubits. We found that a Bell-pair measurement can be performed with flux qubits to prove the existence of an entangled state over two qubits. The pre-ensembled measurement scheme, in which our flux qubit readouts work, is preferable to entangled state measurement.
A hysteretic dc-superconducting quantum interference device (SQUID) is used to trace the flux characteristic of a tunable rf-SQUID, the basic element for the realization of superconducting flux qubits. This allows important simplifications of circuitry and electronics in developing devices for quantum computing, by eliminating the necessity of more complex magnetometers. A hysteretic dc-SQUID is usually operated as a comparator, distinguishing only which one of two adjacent flux states is occupied by the rf-SQUID. The necessary sensitivity, moreover, is usually reached only at temperatures in the mK range. However, by exploiting the statistical properties of the current–voltage curve in the region where the switching from the zero-voltage state occurs, it is possible to obtain an accurate tracing of the input flux, even at a relatively high temperature (a few Kelvin). In our case, the input signal is given by the internal flux of a tunable rf-SQUID, the building block of a flux qubit.