Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0410730 · Physical Review B

Quantum state detection of a superconducting flux qubit using a dc-SQUID in the inductive mode

Adrian Lupaşcu, C. J. P. M. Harmans, Johan E. Mooij

Published May 13, 2005• 25 citations
arXivHTMLPDF

Abstract

We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.

DOI
10.1103/physrevb.71.184506

Related papers

Quiet Readout of Superconducting Flux States

John L. Clarke, John L. Clarke, Timothy L. Robertson +16 more

The INSQUID (INductive Superconducting QUantum Interference Device) can measure the flux state of a superconducting qubit rapidly, while allowing the quantum state of the qubit to evolve with low levels of back action. The INSQUID consists of a dc SQUID with unshunted junctions connected in parallel with a superconducting inductor; the qubit is placed inside the SQUID loop. The inductor is coupled to a readout dc SQUID with resistively-shunted junctions. By applying appropriate fluxes to the input SQUID and the inductor, the INSQUID can be turned "off", so that virtually no flux noise is coupled from the readout SQUID to the qubit. Different flux biases turn the INSQUID "on", enabling the readout SQUID to measure the flux state of the qubit. The INSQUID can also be used to turn on and off the coupling between two or more qubits.

Physica Scripta•Jan 1, 2002•29 citations

Efficiency of underdamped dc SQUIDs as readout devices for flux qubits

Shaoxiong Li, Yang Yu, Wei Qiu +2 more

The flux state quantum bit (qubit) is promising for a solid state implementation of scalable quantum computing. The simplest flux state qubit consists of an rf SQUID with two fluxoid states, which can be readout with a dc SQUID - the most sensitive magnetic flux detector. Efficient readout with less back-action is desirable for quantum computing. In this work, we report measurements of the switching flux and switching current distributions of under damped dc SQUIDs. The data show that single shot readout of flux qubit with very high efficiency (>99%) can be realized using underdamped hysteretic dc SQUIDs.

IEEE Transactions on Applied Superconductivity•Jun 1, 2003•2 citations

Dc SQUID sensitivity for readout of entangled state quantum bits

H Tanaka, Y Sekine, S Saito +1 more

We propose a scheme for entangled state measurement at flux qubits (quantum bits) depending on the sensitivity measurement of a dc SQUID (superconducting quantum interference device). The dc SQUID is used as a flux qubit readout device. The switching current distribution of the dc SQUID is sufficiently narrow to distinguish between two ground states of three Josephson junction qubits with a large mutual inductance between a qubit and the dc SQUID. However, discrimination between two ground states becomes difficult with the smaller mutual inductance that is preferable for qubit coherence. We employed averaging to increase the effective sensitivity. However the averaging smears out the entanglement over two qubits. We found that a Bell-pair measurement can be performed with flux qubits to prove the existence of an entangled state over two qubits. The pre-ensembled measurement scheme, in which our flux qubit readouts work, is preferable to entangled state measurement.

arXiv:cond-mat/0108231•Superconductor Science and Technology•Nov 21, 2001•5 citations

Superconducting quantum interference device with frequency-dependent damping: Readout of flux qubits

Timothy L. Robertson, B. L. T. Plourde, T. Hime +4 more

Recent experiments on superconducting flux qubits, consisting of a superconducting loop interrupted by Josephson junctions, have demonstrated quantum coherence between two different quantum states. The state of the qubit is measured with a superconducting quantum interference device (SQUID). Such measurements require the SQUID to have high resolution while exerting minimal backaction on the qubit. By designing shunts across the SQUID junctions appropriately, one can improve the measurement resolution without increasing the backaction significantly. Using a path-integral approach to analyze the Caldeira-Leggett model, we calculate the narrowing of the distribution of the switching events from the zero-voltage state of the SQUID for arbitrary shunt admittances, focusing on shunts consisting of a capacitance ${C}_{s}$ and resistance ${R}_{s}$ in series. To test this model, we fabricated a dc SQUID in which each junction is shunted with a thin-film interdigitated capacitor in series with a resistor, and measured the switching distribution as a function of temperature and applied magnetic flux. After accounting for the damping due to the SQUID leads, we found good agreement between the measured escape rates and the predictions of our model. We analyze the backaction of a shunted symmetric SQUID on a flux qubit. For the given parameters of our SQUID and realistic parameters for a flux qubit, at the degeneracy point we find a relaxation time of $113\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{s}$, which limits the decoherence time to $226\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{s}$. Based on our analysis of the escape process, we determine that a SQUID with purely capacitive shunts should have narrow switching distributions and no dissipation.

Physical Review B•Jul 11, 2005•23 citations

Low-Back-Action RF SQUID Readout for a Josephson Flux Qubit Measurement

V. I. Shnyrkov, Andrii P. Shapovalov, A.A. Kalenyuk +3 more

Superconducting qubits demonstrate good perspectives as scalable blocks for quantum information processing. These systems can be individually readout, addressed, and controlled, making them some of the most attractive thin-film qubits. Quantum measurements should be performed in order to readout the final state of flux qubits. To observe the dynamics of such systems, one requires a fast magnetometer with exceptional sensitivity and low back-action. We address the problem of reducing the back-action of an RF SQUID readout circuit, which may significantly destroy a Josephson flux qubit in the case of the circuits integration. The main sources of such back-action in conventional RF SQUID and DC SQUID circuits are low-ohmic shunting resistors ensuring high damping. The advantage of flux qubits is the presence of an optimal bias point at which, in the first-order approximation, the device is immune to fluctuations in readout and control lines. Nonetheless, even such systems have characteristics limited by a second-order dissipation. The dissipation can be eliminated by using an “ideal parametric readout” based on an RF SQUID acting in non-hysteretic adiabatic mode. In this paper, we propose an RF SQUID in a non-hysteretic regime as a fast, sensitive, and scalable readout system with low back-action for measurements of a single MW photon counter based on a flux qubit.

IEEE International Conference on Electronics and Information Technologies (ELIT)•May 19, 2021•1 citation

Phase coherent dynamics of a superconducting flux qubit with capacitive bias readout

Frank Deppe, M. Mariantoni, E. P. Menzel +7 more

We present a systematic study of the phase coherent dynamics of a superconducting three-Josephson-junction flux qubit. The qubit state is detected with the integrated-pulse method, which is a variant of the pulsed switching-dc-superconducting quantum interference device (SQUID) method. In this scheme, the dc SQUID bias current pulse is applied via a capacitor instead of a resistor, giving rise to a narrow bandpass instead of a pure low-pass filter configuration of the electromagnetic environment. Measuring one and the same qubit with both setups allows a direct comparison. With the capacitive method about four times faster switching pulses and an increased visibility are achieved. Furthermore, the deliberate engineering of the electromagnetic environment, which minimizes the noise due to the bias circuit, is facilitated. Right at the degeneracy point, the qubit coherence is limited by energy relaxation. We find two main noise contributions. White noise limits the energy relaxation and contributes to the dephasing far from the degeneracy point. $1∕f$ noise is the dominant source of dephasing in the direct vicinity of the optimal point. The influence of $1∕f$ noise is also supported by nonrandom beatings in the Ramsey and spin echo decay traces. Numeric simulations of a coupled qubit-oscillator system indicate that these beatings are due to the resonant interaction of the qubit with at least one pointlike fluctuator, coupled especially strongly to the qubit.

arXiv:0710.4455•Physical Review B•Dec 4, 2007•38 citations
We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.
The INSQUID (INductive Superconducting QUantum Interference Device) can measure the flux state of a superconducting qubit rapidly, while allowing the quantum state of the qubit to evolve with low levels of back action. The INSQUID consists of a dc SQUID with unshunted junctions connected in parallel with a superconducting inductor; the qubit is placed inside the SQUID loop. The inductor is coupled to a readout dc SQUID with resistively-shunted junctions. By applying appropriate fluxes to the input SQUID and the inductor, the INSQUID can be turned "off", so that virtually no flux noise is coupled from the readout SQUID to the qubit. Different flux biases turn the INSQUID "on", enabling the readout SQUID to measure the flux state of the qubit. The INSQUID can also be used to turn on and off the coupling between two or more qubits.
The flux state quantum bit (qubit) is promising for a solid state implementation of scalable quantum computing. The simplest flux state qubit consists of an rf SQUID with two fluxoid states, which can be readout with a dc SQUID - the most sensitive magnetic flux detector. Efficient readout with less back-action is desirable for quantum computing. In this work, we report measurements of the switching flux and switching current distributions of under damped dc SQUIDs. The data show that single shot readout of flux qubit with very high efficiency (>99%) can be realized using underdamped hysteretic dc SQUIDs.
We propose a scheme for entangled state measurement at flux qubits (quantum bits) depending on the sensitivity measurement of a dc SQUID (superconducting quantum interference device). The dc SQUID is used as a flux qubit readout device. The switching current distribution of the dc SQUID is sufficiently narrow to distinguish between two ground states of three Josephson junction qubits with a large mutual inductance between a qubit and the dc SQUID. However, discrimination between two ground states becomes difficult with the smaller mutual inductance that is preferable for qubit coherence. We employed averaging to increase the effective sensitivity. However the averaging smears out the entanglement over two qubits. We found that a Bell-pair measurement can be performed with flux qubits to prove the existence of an entangled state over two qubits. The pre-ensembled measurement scheme, in which our flux qubit readouts work, is preferable to entangled state measurement.
Recent experiments on superconducting flux qubits, consisting of a superconducting loop interrupted by Josephson junctions, have demonstrated quantum coherence between two different quantum states. The state of the qubit is measured with a superconducting quantum interference device (SQUID). Such measurements require the SQUID to have high resolution while exerting minimal backaction on the qubit. By designing shunts across the SQUID junctions appropriately, one can improve the measurement resolution without increasing the backaction significantly. Using a path-integral approach to analyze the Caldeira-Leggett model, we calculate the narrowing of the distribution of the switching events from the zero-voltage state of the SQUID for arbitrary shunt admittances, focusing on shunts consisting of a capacitance Cs{C}_{s}Cs​ and resistance Rs{R}_{s}Rs​ in series. To test this model, we fabricated a dc SQUID in which each junction is shunted with a thin-film interdigitated capacitor in series with a resistor, and measured the switching distribution as a function of temperature and applied magnetic flux. After accounting for the damping due to the SQUID leads, we found good agreement between the measured escape rates and the predictions of our model. We analyze the backaction of a shunted symmetric SQUID on a flux qubit. For the given parameters of our SQUID and realistic parameters for a flux qubit, at the degeneracy point we find a relaxation time of $113\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{s}$, which limits the decoherence time to $226\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{s}$. Based on our analysis of the escape process, we determine that a SQUID with purely capacitive shunts should have narrow switching distributions and no dissipation.
Superconducting qubits demonstrate good perspectives as scalable blocks for quantum information processing. These systems can be individually readout, addressed, and controlled, making them some of the most attractive thin-film qubits. Quantum measurements should be performed in order to readout the final state of flux qubits. To observe the dynamics of such systems, one requires a fast magnetometer with exceptional sensitivity and low back-action. We address the problem of reducing the back-action of an RF SQUID readout circuit, which may significantly destroy a Josephson flux qubit in the case of the circuits integration. The main sources of such back-action in conventional RF SQUID and DC SQUID circuits are low-ohmic shunting resistors ensuring high damping. The advantage of flux qubits is the presence of an optimal bias point at which, in the first-order approximation, the device is immune to fluctuations in readout and control lines. Nonetheless, even such systems have characteristics limited by a second-order dissipation. The dissipation can be eliminated by using an “ideal parametric readout” based on an RF SQUID acting in non-hysteretic adiabatic mode. In this paper, we propose an RF SQUID in a non-hysteretic regime as a fast, sensitive, and scalable readout system with low back-action for measurements of a single MW photon counter based on a flux qubit.
We present a systematic study of the phase coherent dynamics of a superconducting three-Josephson-junction flux qubit. The qubit state is detected with the integrated-pulse method, which is a variant of the pulsed switching-dc-superconducting quantum interference device (SQUID) method. In this scheme, the dc SQUID bias current pulse is applied via a capacitor instead of a resistor, giving rise to a narrow bandpass instead of a pure low-pass filter configuration of the electromagnetic environment. Measuring one and the same qubit with both setups allows a direct comparison. With the capacitive method about four times faster switching pulses and an increased visibility are achieved. Furthermore, the deliberate engineering of the electromagnetic environment, which minimizes the noise due to the bias circuit, is facilitated. Right at the degeneracy point, the qubit coherence is limited by energy relaxation. We find two main noise contributions. White noise limits the energy relaxation and contributes to the dephasing far from the degeneracy point. 1∕f1∕f1∕f noise is the dominant source of dephasing in the direct vicinity of the optimal point. The influence of 1∕f1∕f1∕f noise is also supported by nonrandom beatings in the Ramsey and spin echo decay traces. Numeric simulations of a coupled qubit-oscillator system indicate that these beatings are due to the resonant interaction of the qubit with at least one pointlike fluctuator, coupled especially strongly to the qubit.