Dual channel self-oscillating optical magnetometer

Jacopo Belfi, G. Bevilacqua, V. Biancalana, S. Cartaleva, Yordanka V. Dancheva, K. Khanbekyan, L. Moi

Published Apr 3, 2009• 30 citations
arXivHTMLPDF

Abstract

We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.

DOI
10.1364/josab.26.000910

Related papers

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•11 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•6 citations

Compact, high-sensitivity atomic magnetometer utilizing the light-narrowing effect and in-phase excitation

Yuhao Guo, Shuangai Wan, Xiaoguang Sun +1 more

A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.

Applied Optics•Jan 17, 2019•29 citations

A highly drift-stable atomic magnetometer for fundamental physics experiments

Martin Rosner, BECK Douglas howard, P. Fierlinger +7 more

We report the design and performance of a nonmagnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 and 600 s. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell–Bloom configuration, a higher order polarization moment (alignment) of Cs atoms is created with a pump laser beam in an anti-relaxation coated Pyrex cell under vacuum, filled with Cs vapor at room temperature. The polarization plane of light passing through the cell is modulated due the precession of the atoms in an external magnetic field of 2.1 μT, used to optically determine the Larmor precession frequency. Operation is based on a sequence of optical pumping and observation of freely precessing spins at a repetition rate of 8 Hz. This free precession decay readout scheme separates optical pumping and probing and, thus, ensures a systematically highly clean measurement. Due to the residual offset of the sensor of <15 pT together with negligible crosstalk of adjacent sensors, this device is uniquely suitable for a variety of experiments in low-energy particle physics with extreme precision, here as a highly stable and systematically clean reference probe in search for time-reversal symmetry violating electric dipole moments.

arXiv:2201.06936•Applied Physics Letters•Apr 18, 2022•30 citations

Free-induction-decay magnetometer based on synchronous optical pumping and RF pulse modulation

Jinghong Xu, Liwei Jiang, Junhao Liu +7 more

Free-induction-decay (FID) magnetometer is highly suitable for precise magnetic field sensing in unshielded environments with the benefit of exceptional accuracy and large dynamic range. The sensitivity of the FID magnetometer is directly influenced by the signal-to-noise ratio, making it critical to enhance the amplitude of the FID signal. In this study, we propose a FID magnetometer based on synchronous optical pumping and RF pulse modulation. A comprehensive theoretical description of the magnetometer is introduced, followed by simulation and experiment that compare the proposed modulation method with the synchronous optical pumping modulation method and the RF pulse modulation method. The results show that the synchronous optical pumping and RF pulse modulation achieves the enhancement of the FID signal and improves the magnetometer sensitivity. Furthermore, the dead zone of the magnetometer is reduced to the direction of the probe beam. This work is significant for further development of optically pumped magnetometers and provides a new scheme for their applications in unshielded environments.

EPJ Quantum Technology•May 30, 2025•10 citations

Improving the sensitivity of optically pumped magnetometers by hyperfine repumping

V. Schultze, Theo Scholtes, R.P.J. IJsselsteijn +1 more

Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F=4 pumping: F=3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F=3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the Mx and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the Mx mode it is more pronounced (about 50 versus 200 fT/√Hz for a 50 mm3 Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed.

Journal of the Optical Society of America B•Apr 2, 2015•20 citations
We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.
We report the design and performance of a nonmagnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 and 600 s. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell–Bloom configuration, a higher order polarization moment (alignment) of Cs atoms is created with a pump laser beam in an anti-relaxation coated Pyrex cell under vacuum, filled with Cs vapor at room temperature. The polarization plane of light passing through the cell is modulated due the precession of the atoms in an external magnetic field of 2.1 μT, used to optically determine the Larmor precession frequency. Operation is based on a sequence of optical pumping and observation of freely precessing spins at a repetition rate of 8 Hz. This free precession decay readout scheme separates optical pumping and probing and, thus, ensures a systematically highly clean measurement. Due to the residual offset of the sensor of <15 pT together with negligible crosstalk of adjacent sensors, this device is uniquely suitable for a variety of experiments in low-energy particle physics with extreme precision, here as a highly stable and systematically clean reference probe in search for time-reversal symmetry violating electric dipole moments.
Free-induction-decay (FID) magnetometer is highly suitable for precise magnetic field sensing in unshielded environments with the benefit of exceptional accuracy and large dynamic range. The sensitivity of the FID magnetometer is directly influenced by the signal-to-noise ratio, making it critical to enhance the amplitude of the FID signal. In this study, we propose a FID magnetometer based on synchronous optical pumping and RF pulse modulation. A comprehensive theoretical description of the magnetometer is introduced, followed by simulation and experiment that compare the proposed modulation method with the synchronous optical pumping modulation method and the RF pulse modulation method. The results show that the synchronous optical pumping and RF pulse modulation achieves the enhancement of the FID signal and improves the magnetometer sensitivity. Furthermore, the dead zone of the magnetometer is reduced to the direction of the probe beam. This work is significant for further development of optically pumped magnetometers and provides a new scheme for their applications in unshielded environments.
Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F=4 pumping: F=3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F=3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the Mx and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the Mx mode it is more pronounced (about 50 versus 200 fT/√Hz for a 50 mm3 Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed.