EPJ Quantum Technology

Free-induction-decay magnetometer based on synchronous optical pumping and RF pulse modulation

Jinghong Xu, Liwei Jiang, Junhao Liu, Jiali Liu, Yuanqiang Chen, Jun Zhu, Chi Fang, Qi Shao, Yuntian Zou, Huijing Bai

Published May 30, 2025• 10 citations
Publisher

Abstract

Free-induction-decay (FID) magnetometer is highly suitable for precise magnetic field sensing in unshielded environments with the benefit of exceptional accuracy and large dynamic range. The sensitivity of the FID magnetometer is directly influenced by the signal-to-noise ratio, making it critical to enhance the amplitude of the FID signal. In this study, we propose a FID magnetometer based on synchronous optical pumping and RF pulse modulation. A comprehensive theoretical description of the magnetometer is introduced, followed by simulation and experiment that compare the proposed modulation method with the synchronous optical pumping modulation method and the RF pulse modulation method. The results show that the synchronous optical pumping and RF pulse modulation achieves the enhancement of the FID signal and improves the magnetometer sensitivity. Furthermore, the dead zone of the magnetometer is reduced to the direction of the probe beam. This work is significant for further development of optically pumped magnetometers and provides a new scheme for their applications in unshielded environments.

DOI
10.1140/epjqt/s40507-025-00373-y

Related papers

Dead-zone-free orientation-based pulsed atomic magnetometer

Jinghong Xu, Liwei Jiang, Yuntian Zou +6 more

The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.

Physical Review Research•Apr 6, 2026•0 citations

Free Induction Decay Optically Pumped Magnetometers: A Review

Jiarui Liu, Xiao Liu, Yuantian Lu +4 more

Free induction decay (FID) optically pumped magnetometers are among the most sensitive quantum sensors available for high-precision magnetic field measurements. This review summarizes recent advances in FID magnetometers, which represent a critical technological route that suppresses systematic errors by temporally separating atomic polarization from magnetic field detection. This review covers light-modulated optical pumping schemes (such as the Bell-Bloom mode), radio-frequency excitation schemes, and magnetic-field-enhanced pumping schemes. Key technological developments, including chip-scale MEMS fabrication, optical multipass architectures, advanced frequency estimation algorithms, and error suppression methods, are also discussed. Finally, emerging trends toward higher integration, environmental robustness, and intelligent signal demodulation are highlighted. These trends provide insights into the development of next-generation high-performance quantum sensors and their growing role in biomedical and geophysical applications, as well as in fundamental scientific research.

Sensors•Sep 26, 2026•0 citations

Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms

Shrey Mehta, G. K. Samanta, Raghwinder Singh Grewal

Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.

arXiv:2410.15663•Applied Physics Letters•Jan 27, 2025•8 citations

A Multi-Pass Optically Pumped Rubidium Atomic Magnetometer with Free Induction Decay

Lulu Zhang, Yongbiao Yang, Ni Zhao +2 more

A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.

arXiv:2301.08437•Sensors•Oct 7, 2022•18 citations

Free-induction-decay 4 He magnetometer using a multipass cell

Kaiwen Yi, Yang Liu, Bowen Wang +4 more

Optically pumped magnetometers (OPMs) based on the free-induction-decay (FID) configuration have recently attracted interest owing to their advantages, such as being calibration-free, easy to operate, and showing reduced light shifts induced by the pump light. Currently, alkali-metal vapor cells have been employed in most of the FID magnetometers. However, the relatively narrow linewidth of the magnetic resonance signal and nonlinear Zeeman (NLZ) effects generate bandwidth limitation and heading errors of these magnetometers in the Earth's field, respectively. In this work, we propose a ${}^{4}\mathrm{He}$-based FID magnetometer, which not only has the advantages of being NLZ-free and showing a high bandwidth, but also maintains an enhanced sensitivity assisted by a multipass cell. This magnetometer demonstrates a magnetic field noise floor of $0.34\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/{\mathrm{Hz}}^{1/2}$ with a Nyquist-limited bandwidth of $5$ kHz, which opens another route for atomic magnetometry using FID signals, and exhibits potential for applications in high-frequency magnetic field detection, such as biomagnetic measurements and magnetic communications in the geomagnetic field.

Physical Review Applied•Jul 31, 2024•25 citations

Optical pumping enhancement of a free-induction-decay magnetometer

Dominic Hunter, Marcin S. Mrozowski, Allan McWilliam +4 more

Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two orders of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of 238fT/Hz was achieved in a field of approximately 50 µT, in close agreement with the Cramér–Rao lower bound predicted noise density of 258fT/Hz.

arXiv:2307.11600•Journal of the Optical Society of America B•Sep 18, 2023•22 citations
Free-induction-decay (FID) magnetometer is highly suitable for precise magnetic field sensing in unshielded environments with the benefit of exceptional accuracy and large dynamic range. The sensitivity of the FID magnetometer is directly influenced by the signal-to-noise ratio, making it critical to enhance the amplitude of the FID signal. In this study, we propose a FID magnetometer based on synchronous optical pumping and RF pulse modulation. A comprehensive theoretical description of the magnetometer is introduced, followed by simulation and experiment that compare the proposed modulation method with the synchronous optical pumping modulation method and the RF pulse modulation method. The results show that the synchronous optical pumping and RF pulse modulation achieves the enhancement of the FID signal and improves the magnetometer sensitivity. Furthermore, the dead zone of the magnetometer is reduced to the direction of the probe beam. This work is significant for further development of optically pumped magnetometers and provides a new scheme for their applications in unshielded environments.
The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.
Free induction decay (FID) optically pumped magnetometers are among the most sensitive quantum sensors available for high-precision magnetic field measurements. This review summarizes recent advances in FID magnetometers, which represent a critical technological route that suppresses systematic errors by temporally separating atomic polarization from magnetic field detection. This review covers light-modulated optical pumping schemes (such as the Bell-Bloom mode), radio-frequency excitation schemes, and magnetic-field-enhanced pumping schemes. Key technological developments, including chip-scale MEMS fabrication, optical multipass architectures, advanced frequency estimation algorithms, and error suppression methods, are also discussed. Finally, emerging trends toward higher integration, environmental robustness, and intelligent signal demodulation are highlighted. These trends provide insights into the development of next-generation high-performance quantum sensors and their growing role in biomedical and geophysical applications, as well as in fundamental scientific research.
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.
A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.
Optically pumped magnetometers (OPMs) based on the free-induction-decay (FID) configuration have recently attracted interest owing to their advantages, such as being calibration-free, easy to operate, and showing reduced light shifts induced by the pump light. Currently, alkali-metal vapor cells have been employed in most of the FID magnetometers. However, the relatively narrow linewidth of the magnetic resonance signal and nonlinear Zeeman (NLZ) effects generate bandwidth limitation and heading errors of these magnetometers in the Earth's field, respectively. In this work, we propose a 4He{}^{4}\mathrm{He}4He-based FID magnetometer, which not only has the advantages of being NLZ-free and showing a high bandwidth, but also maintains an enhanced sensitivity assisted by a multipass cell. This magnetometer demonstrates a magnetic field noise floor of 0.34pT/Hz1/20.34\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/{\mathrm{Hz}}^{1/2}0.34pT/Hz1/2 with a Nyquist-limited bandwidth of 555 kHz, which opens another route for atomic magnetometry using FID signals, and exhibits potential for applications in high-frequency magnetic field detection, such as biomagnetic measurements and magnetic communications in the geomagnetic field.
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two orders of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of 238fT/Hz was achieved in a field of approximately 50 µT, in close agreement with the Cramér–Rao lower bound predicted noise density of 258fT/Hz.