Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2410.15663 · Applied Physics Letters

Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms

Shrey Mehta, G. K. Samanta, Raghwinder Singh Grewal

Published Jan 27, 2025• 8 citations
arXivHTMLPDF

Abstract

Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.

DOI
10.1063/5.0248330

Related papers

Dead-zone-free orientation-based pulsed atomic magnetometer

Jinghong Xu, Liwei Jiang, Yuntian Zou +6 more

The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.

Physical Review Research•Apr 6, 2026•0 citations

Dead-zone-free free-induction-decay alkali-metal atomic magnetometer

X.-K. Wang, J. He, HH Deng +2 more

The detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead zone free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass cavity assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three dimensional space, and a field sensitivity better than 80 fT/Hz^(1/2) over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed loop mode by feeding back the real time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work paves the way towards a sensitive vector FID magnetometer.

arXiv:2609.04847•Physical Review A•Aug 25, 2026•0 citations

A Multi-Pass Optically Pumped Rubidium Atomic Magnetometer with Free Induction Decay

Lulu Zhang, Yongbiao Yang, Ni Zhao +2 more

A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.

arXiv:2301.08437•Sensors•Oct 7, 2022•18 citations

Free-induction-decay magnetometer based on synchronous optical pumping and RF pulse modulation

Jinghong Xu, Liwei Jiang, Junhao Liu +7 more

Free-induction-decay (FID) magnetometer is highly suitable for precise magnetic field sensing in unshielded environments with the benefit of exceptional accuracy and large dynamic range. The sensitivity of the FID magnetometer is directly influenced by the signal-to-noise ratio, making it critical to enhance the amplitude of the FID signal. In this study, we propose a FID magnetometer based on synchronous optical pumping and RF pulse modulation. A comprehensive theoretical description of the magnetometer is introduced, followed by simulation and experiment that compare the proposed modulation method with the synchronous optical pumping modulation method and the RF pulse modulation method. The results show that the synchronous optical pumping and RF pulse modulation achieves the enhancement of the FID signal and improves the magnetometer sensitivity. Furthermore, the dead zone of the magnetometer is reduced to the direction of the probe beam. This work is significant for further development of optically pumped magnetometers and provides a new scheme for their applications in unshielded environments.

EPJ Quantum Technology•May 30, 2025•10 citations

Dead-Zone-Free Atomic Magnetometry with Simultaneous Excitation of Orientation and Alignment Resonances

Amit Ben-Kish, Michael V. Romalis

Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones," certain orientations of the magnetic field where the magnetometer loses its sensitivity. We demonstrate a simple polarization modulation scheme that simultaneously creates coherent population trapping (CPT) in orientation and alignment, thereby eliminating dead zones. Using 87Rb in a 10 Torr buffer gas cell we measure narrow, high-contrast CPT transparency peaks for all orientations and also show the absence of systematic effects associated with nonlinear Zeeman splitting.

arXiv:1001.0345•Physical Review Letters•Nov 4, 2010•87 citations

A dead-zone free 4He atomic magnetometer with intensity-modulated linearly polarized light and a liquid crystal polarization rotator

Teng Wu, Xiang Peng, Zaisheng Lin +1 more

We demonstrate an all-optical (4)He atomic magnetometer experimental scheme based on an original Bell-Bloom configuration. A single intensity-modulated linearly polarized laser beam is used both for generating spin polarization within a single (4)He vapor and probing the spin precessing under a static magnetic field. The transmitted light signal from the vapor is then phase-sensitively detected at the modulation frequency and its harmonics, which lead to the atomic magnetic resonance signals. Based on this structure, a liquid crystal is added in our magnetometer system and constitutes a polarization rotator. By controlling the voltage applied on the liquid crystal, the light linear polarization vector can be kept perpendicular with the ambient magnetic field direction, which in turn provides the maximum resonance signal amplitude. Moreover, the system exhibits a magnetic-field noise floor of about 2pT/√Hz, which is not degraded due to the presence of the liquid crystal and varying magnetic field direction. The experiment results prove that our method can eliminate the dead-zone effect, improve the system spatial isotropy, and thus be suitable in mobile applications.

Review of Scientific Instruments•Oct 1, 2015•25 citations
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.
The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.
The detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead zone free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass cavity assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three dimensional space, and a field sensitivity better than 80 fT/Hz^(1/2) over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed loop mode by feeding back the real time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work paves the way towards a sensitive vector FID magnetometer.
A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.
Free-induction-decay (FID) magnetometer is highly suitable for precise magnetic field sensing in unshielded environments with the benefit of exceptional accuracy and large dynamic range. The sensitivity of the FID magnetometer is directly influenced by the signal-to-noise ratio, making it critical to enhance the amplitude of the FID signal. In this study, we propose a FID magnetometer based on synchronous optical pumping and RF pulse modulation. A comprehensive theoretical description of the magnetometer is introduced, followed by simulation and experiment that compare the proposed modulation method with the synchronous optical pumping modulation method and the RF pulse modulation method. The results show that the synchronous optical pumping and RF pulse modulation achieves the enhancement of the FID signal and improves the magnetometer sensitivity. Furthermore, the dead zone of the magnetometer is reduced to the direction of the probe beam. This work is significant for further development of optically pumped magnetometers and provides a new scheme for their applications in unshielded environments.
Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones," certain orientations of the magnetic field where the magnetometer loses its sensitivity. We demonstrate a simple polarization modulation scheme that simultaneously creates coherent population trapping (CPT) in orientation and alignment, thereby eliminating dead zones. Using 87Rb in a 10 Torr buffer gas cell we measure narrow, high-contrast CPT transparency peaks for all orientations and also show the absence of systematic effects associated with nonlinear Zeeman splitting.
We demonstrate an all-optical (4)He atomic magnetometer experimental scheme based on an original Bell-Bloom configuration. A single intensity-modulated linearly polarized laser beam is used both for generating spin polarization within a single (4)He vapor and probing the spin precessing under a static magnetic field. The transmitted light signal from the vapor is then phase-sensitively detected at the modulation frequency and its harmonics, which lead to the atomic magnetic resonance signals. Based on this structure, a liquid crystal is added in our magnetometer system and constitutes a polarization rotator. By controlling the voltage applied on the liquid crystal, the light linear polarization vector can be kept perpendicular with the ambient magnetic field direction, which in turn provides the maximum resonance signal amplitude. Moreover, the system exhibits a magnetic-field noise floor of about 2pT/√Hz, which is not degraded due to the presence of the liquid crystal and varying magnetic field direction. The experiment results prove that our method can eliminate the dead-zone effect, improve the system spatial isotropy, and thus be suitable in mobile applications.