Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0810.4055 · Journal of Modern Optics

Self-consistent characterization of light statistics

Maria Bondani, Alessia Allevi, Andrea Agliati, Alessandra Andreoni

Published Jan 20, 2009• 76 citations
arXivHTMLPDF

Abstract

We demonstrate the possibility of a self-consistent characterization of the photon-number statistics of a light field by using photoemissive detectors with internal gain simply endowed with linear input/output responses. The method can be applied to both microscopic and mesoscopic photon-number regimes. The detectors must operate in the linear range without the need for photon-counting capabilities.

DOI
10.1080/09500340802357307

Related papers

Light Statistics by Non-Calibrated Linear Photodetectors

Maria Bondani, Alessia Allevi, Alessandra Andreoni

We theoretically demonstrate that detectors endowed with internal gain and operated in regimes in which they do not necessarily behave as photon-counters, but still ensure linear input/output responses, can allow a self-consistent characterization of the statistics of the number of detected photons without need of knowing their gain. We present experiments performed with a photo-emissive hybrid detector on a number of classical fields endowed with non-trivial statistics and show that the method works for both microscopic and mesoscopic photon numbers. The obtained detected-photon probability distributions agree with those expected for the photon numbers, which are also reconstructed by an independent method.

arXiv:0810.4026•Advanced Science Letters•Dec 1, 2009•49 citations

Photon statistics in the macroscopic realm measured without photon counters

Alessandra Andreoni, Maria Bondani

In a macroscopic realm, in which photons are too many to be counted by any photon-counting detector, photon statistics can be measured by using detectors simply endowed with linear response. We insert one of such detectors in a conventional photon-counting apparatus, which returns a voltage every time the detector responds to light by generating a number of elementary charges via its primary photodetection process. We only assume that, when a single charge is photogenerated, the probability density of the voltages is a distribution that is narrow with respect to its mean value. Under this hypothesis the output voltages can be suitably binned so that their probability distribution is the same as that of the photogenerated charges, that is, of the detected photons.

arXiv:0906.2662•Physical Review A•Jul 22, 2009•33 citations

CHOOSING A PHOTOEMISSIVE DETECTOR SUITABLE FOR PHOTON-NUMBER STATISTICS OF PULSED FIELDS

Maria Bondani, Alessia Allevi, Alessandra Andreoni

We investigate the possibility of using linear detectors that exhibit a response to dark just resolved from that corresponding to a single detected photon to reconstruct the photon-number statistics of pulsed fields containing sizeable numbers of photons per pulse. We demonstrate that by applying a self-consistent procedure to analyze the output pulses of such detectors, we can properly measure statistical distributions of the number of detected photons and photon number correlations. The lack of fulfillment of such minimal requirements impairs the possibility of reliable shot-by-shot determinations of photon numbers.

International Journal of Quantum Information•Jan 1, 2011•2 citations

Photon-number correlations by photon-number resolving detectors

Alessia Allevi, Maria Bondani, Alessandra Andreoni

We demonstrate that by using pairs of photodetectors endowed with internal gain we are able to quantify the photon-number correlation coefficient between the two components of a pulsed bipartite state in the "mesoscopic" intensity regime (less than 100 mean photons). We compare the performances of hybrid photoemissive detectors to those of multipixel silicon photon counters and demonstrate that the absence of significant noise allows the evaluation of the variance of the distribution of the differences in photon numbers, and hence of the shot-noise level, without any correction.

arXiv:1002.0210•Optics Letters•May 13, 2010•44 citations

Linearity and scalability of photon counting: toward accurate multiparameter photonic sensing

Miroslav Ježek

We introduce the direct linearity characterization of single-photon detectors and photon-number-resolving detectors. We discuss the supralinearity that goes beyond the current single-photon detection models. We also report on advanced detectors and sensors of statistical, vector, and correlation properties of light down to the single-photon level. The novel detection schemes harness complex optical networks, single-photon detector arrays, and deep learning. We present high-fidelity photon statistics estimation, resource-efficient polarization sensor, and quantum entanglement detector. We discuss the efficiency and scaling of the presented detection modalities.

Quantum Optics and Photon Counting•Jun 6, 2025•0 citations

Generation and Detection of Mesoscopic Pulsed States of Light for Quantum Information

Alessia Allevi, Maria Bondani

Generation and measurement of quantum states of the electromagnetic field represent a hot and widely discussed topic in the Physics community, since optical states are useful not only in fundamental experiments but also in several applications in the fields of Quantum Optics and Quantum Information (Bouwmeester et al., 2000). In fact, optical radiation is endowed with relevant characteristics as it travels at maximum possible speed, it is almost unaffected by the interaction with the environment, which in many cases represents an unavoidable decoherence source, and it can be integrated in optoelectronic circuits to implement quantum computing protocols (Sansoni et al., 2010). The possibility of using optical fields in applicative protocols depends on the capability of generating and manipulating optical states that are robust with respect to losses (i.e. that contain a sizeable number of photons) and that can be produced and measured at high rate. For all these reasons, mesoscopic pulsed optical states containing few tens of photons per pulse seem to be the ideal candidates for applications to quantum communication protocols in which each pulse must be addressed individually. Moreover, the problem of generating suitable pulsed states must be considered together with the question of their measurement and characterization. In fact, nowadays we have many types of pulsed-light sources at our disposal, each of them characterized by different pulse durations (from few fs up to few ns), different pulse-repetition rates (from few Hz to 100 MHz) and a wide range of energies per pulse (from few nJ to several J). However, not all these pulsed light can be easily measured. In the mesoscopic intensity regime, for example, detectors endowed with photon-number resolution are required so as to determine shot-by-shot photon numbers or, at least, to characterize some features of the optical states. In fact, full characterization of the optical state, obtained e.g. by evaluating its Wigner function, can be achieved with optical homodyne tomography (OHT) (Raymer, 1997), a technique that over the years has proved its effectiveness in reconstructing both classical and quantum states, even if further optimizations are needed in the case of pulsed fields (Zavatta et al., 2006). Direct detection schemes are an alternative to OHT in all the cases in which knowing the statistics of detected photons is sufficient to characterize the signal state, as demonstrated in the pioneering work of Arecchi (Arecchi, 1965). Obviously, the implementation of a direct detection scheme requires a proper choice of the detector, the development of a calibration 11

InTech eBooks•Nov 14, 2011•2 citations
We demonstrate the possibility of a self-consistent characterization of the photon-number statistics of a light field by using photoemissive detectors with internal gain simply endowed with linear input/output responses. The method can be applied to both microscopic and mesoscopic photon-number regimes. The detectors must operate in the linear range without the need for photon-counting capabilities.
We theoretically demonstrate that detectors endowed with internal gain and operated in regimes in which they do not necessarily behave as photon-counters, but still ensure linear input/output responses, can allow a self-consistent characterization of the statistics of the number of detected photons without need of knowing their gain. We present experiments performed with a photo-emissive hybrid detector on a number of classical fields endowed with non-trivial statistics and show that the method works for both microscopic and mesoscopic photon numbers. The obtained detected-photon probability distributions agree with those expected for the photon numbers, which are also reconstructed by an independent method.
In a macroscopic realm, in which photons are too many to be counted by any photon-counting detector, photon statistics can be measured by using detectors simply endowed with linear response. We insert one of such detectors in a conventional photon-counting apparatus, which returns a voltage every time the detector responds to light by generating a number of elementary charges via its primary photodetection process. We only assume that, when a single charge is photogenerated, the probability density of the voltages is a distribution that is narrow with respect to its mean value. Under this hypothesis the output voltages can be suitably binned so that their probability distribution is the same as that of the photogenerated charges, that is, of the detected photons.
We investigate the possibility of using linear detectors that exhibit a response to dark just resolved from that corresponding to a single detected photon to reconstruct the photon-number statistics of pulsed fields containing sizeable numbers of photons per pulse. We demonstrate that by applying a self-consistent procedure to analyze the output pulses of such detectors, we can properly measure statistical distributions of the number of detected photons and photon number correlations. The lack of fulfillment of such minimal requirements impairs the possibility of reliable shot-by-shot determinations of photon numbers.
We demonstrate that by using pairs of photodetectors endowed with internal gain we are able to quantify the photon-number correlation coefficient between the two components of a pulsed bipartite state in the "mesoscopic" intensity regime (less than 100 mean photons). We compare the performances of hybrid photoemissive detectors to those of multipixel silicon photon counters and demonstrate that the absence of significant noise allows the evaluation of the variance of the distribution of the differences in photon numbers, and hence of the shot-noise level, without any correction.
We introduce the direct linearity characterization of single-photon detectors and photon-number-resolving detectors. We discuss the supralinearity that goes beyond the current single-photon detection models. We also report on advanced detectors and sensors of statistical, vector, and correlation properties of light down to the single-photon level. The novel detection schemes harness complex optical networks, single-photon detector arrays, and deep learning. We present high-fidelity photon statistics estimation, resource-efficient polarization sensor, and quantum entanglement detector. We discuss the efficiency and scaling of the presented detection modalities.
Generation and measurement of quantum states of the electromagnetic field represent a hot and widely discussed topic in the Physics community, since optical states are useful not only in fundamental experiments but also in several applications in the fields of Quantum Optics and Quantum Information (Bouwmeester et al., 2000). In fact, optical radiation is endowed with relevant characteristics as it travels at maximum possible speed, it is almost unaffected by the interaction with the environment, which in many cases represents an unavoidable decoherence source, and it can be integrated in optoelectronic circuits to implement quantum computing protocols (Sansoni et al., 2010). The possibility of using optical fields in applicative protocols depends on the capability of generating and manipulating optical states that are robust with respect to losses (i.e. that contain a sizeable number of photons) and that can be produced and measured at high rate. For all these reasons, mesoscopic pulsed optical states containing few tens of photons per pulse seem to be the ideal candidates for applications to quantum communication protocols in which each pulse must be addressed individually. Moreover, the problem of generating suitable pulsed states must be considered together with the question of their measurement and characterization. In fact, nowadays we have many types of pulsed-light sources at our disposal, each of them characterized by different pulse durations (from few fs up to few ns), different pulse-repetition rates (from few Hz to 100 MHz) and a wide range of energies per pulse (from few nJ to several J). However, not all these pulsed light can be easily measured. In the mesoscopic intensity regime, for example, detectors endowed with photon-number resolution are required so as to determine shot-by-shot photon numbers or, at least, to characterize some features of the optical states. In fact, full characterization of the optical state, obtained e.g. by evaluating its Wigner function, can be achieved with optical homodyne tomography (OHT) (Raymer, 1997), a technique that over the years has proved its effectiveness in reconstructing both classical and quantum states, even if further optimizations are needed in the case of pulsed fields (Zavatta et al., 2006). Direct detection schemes are an alternative to OHT in all the cases in which knowing the statistics of detected photons is sufficient to characterize the signal state, as demonstrated in the pioneering work of Arecchi (Arecchi, 1965). Obviously, the implementation of a direct detection scheme requires a proper choice of the detector, the development of a calibration 11