Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1002.0210 · Optics Letters

Photon-number correlations by photon-number resolving detectors

Alessia Allevi, Maria Bondani, Alessandra Andreoni

Published May 13, 2010• 44 citations
arXivHTMLPDF

Abstract

We demonstrate that by using pairs of photodetectors endowed with internal gain we are able to quantify the photon-number correlation coefficient between the two components of a pulsed bipartite state in the "mesoscopic" intensity regime (less than 100 mean photons). We compare the performances of hybrid photoemissive detectors to those of multipixel silicon photon counters and demonstrate that the absence of significant noise allows the evaluation of the variance of the distribution of the differences in photon numbers, and hence of the shot-noise level, without any correction.

DOI
10.1364/ol.35.001707

Related papers

Light Statistics by Non-Calibrated Linear Photodetectors

Maria Bondani, Alessia Allevi, Alessandra Andreoni

We theoretically demonstrate that detectors endowed with internal gain and operated in regimes in which they do not necessarily behave as photon-counters, but still ensure linear input/output responses, can allow a self-consistent characterization of the statistics of the number of detected photons without need of knowing their gain. We present experiments performed with a photo-emissive hybrid detector on a number of classical fields endowed with non-trivial statistics and show that the method works for both microscopic and mesoscopic photon numbers. The obtained detected-photon probability distributions agree with those expected for the photon numbers, which are also reconstructed by an independent method.

arXiv:0810.4026•Advanced Science Letters•Dec 1, 2009•49 citations

PHOTON-NUMBER CORRELATION OF A CLASSICAL EXOTIC STATE IN THE MESOSCOPIC REGIME

Alessia Allevi, Federica A. Beduini, Maria Bondani +1 more

We demonstrate that by using a pair of hybrid photodetectors, it is possible to quantify the photon-number correlation coefficient between the components of a classical state described by non-trivial statistics and by a non-Gaussian Wigner function. The measurements, performed in the quite unexplored mesoscopic domain (up to 100 photons incident onto the detector), are in good agreement with the theoretical predictions, and thus open the possibility of performing further tests on this exotic state for its application in the field of quantum information.

International Journal of Quantum Information•Jan 1, 2011•5 citations

Photon-number-resolving detectors and their role in quantifying quantum correlations

Si-Hui Tan, Leonid A. Krivitsky, Berthold‐Georg Englert

Harnessing entanglement as a resource is the main workhorse of many quantum protocols, and establishing the degree of quantum correlations of quantum states is an important certification process that has to take place prior to any implementations of these quantum protocols. The emergence of photodetectors known as photon-number-resolving detectors (PNRDs) that allow for accounting of photon numbers simultaneously arriving at the detectors has led to the need for modeling accurately and applying them for use in the certification process. Here we study the variance of difference of photocounts (VDP) of two PNRDs, which is one measure of quantum correlations, under the effects of loss and saturation. We found that it would be possible to distinguish between the classical correlation of a two-mode coherent state and the quantum correlation of a twin-beam state within some photo count regime of the detector. We compare the behavior of two such PNRDs. The first for which the photocount statistics follow a binomial distribution accounting for losses, and the second is that of Agarwal, Vogel, and Sperling for which the incident beam is first split and then separately measured by ON/OFF detectors. In our calculations, analytical expressions are derived for the variance of difference where possible. In these cases, Gauss' hypergeometric function appears regularly, giving an insight to the type of quantum statistics the photon counting gives in these PNRDs. The different mechanisms of the two types of PNRDs leads to quantitative differences in their VDP.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 4, 2016•1 citation

Self-consistent characterization of light statistics

Maria Bondani, Alessia Allevi, Andrea Agliati +1 more

We demonstrate the possibility of a self-consistent characterization of the photon-number statistics of a light field by using photoemissive detectors with internal gain simply endowed with linear input/output responses. The method can be applied to both microscopic and mesoscopic photon-number regimes. The detectors must operate in the linear range without the need for photon-counting capabilities.

arXiv:0810.4055•Journal of Modern Optics•Jan 20, 2009•76 citations

Reliable source of conditional states by multiple-photon subtraction using hybrid photodetectors

Maria Bondani, Alessia Allevi, Marco G. Genoni +3 more

By using hybrid photodetectors we exploited the photon-number correlations existing in bipartite optical states to demonstrate the effect of multiple-photon subtraction on the generation of conditional states in the pulsed regime. We operated on both classical and quantum Gaussian bipartite states in the mesoscopic regime without background subtraction and corrections. The obtained conditional states are non-Gaussian in nature, thus particularly useful for applications to Quantum Information. All the experimental results are in excellent agreement with theoretical models.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 1, 2012•2 citations

HIGH-ORDER PHOTON-NUMBER CORRELATIONS: A RESOURCE FOR CHARACTERIZATION AND APPLICATIONS OF QUANTUM STATES

Alessia Allevi, Stefano Olivares, Maria Bondani

We measure high-order correlation functions of detected-photon numbers in the mesoscopic regime by means of hybrid photodetectors. The analytical expressions for correlations are evaluated in terms of quantities that can be experimentally accessed by a selfconsistent analysis of the detectors' outputs. We demonstrate that high-order correlations can be used to characterize the nature of the optical states, for instance by better discriminating between classical and quantum behavior even in critical situations, such as multimode twin-beam state. The results are in very good agreement with the theory, both for classical states and quantum states.

International Journal of Quantum Information•Dec 1, 2012•34 citations
We demonstrate that by using pairs of photodetectors endowed with internal gain we are able to quantify the photon-number correlation coefficient between the two components of a pulsed bipartite state in the "mesoscopic" intensity regime (less than 100 mean photons). We compare the performances of hybrid photoemissive detectors to those of multipixel silicon photon counters and demonstrate that the absence of significant noise allows the evaluation of the variance of the distribution of the differences in photon numbers, and hence of the shot-noise level, without any correction.
We theoretically demonstrate that detectors endowed with internal gain and operated in regimes in which they do not necessarily behave as photon-counters, but still ensure linear input/output responses, can allow a self-consistent characterization of the statistics of the number of detected photons without need of knowing their gain. We present experiments performed with a photo-emissive hybrid detector on a number of classical fields endowed with non-trivial statistics and show that the method works for both microscopic and mesoscopic photon numbers. The obtained detected-photon probability distributions agree with those expected for the photon numbers, which are also reconstructed by an independent method.
We demonstrate that by using a pair of hybrid photodetectors, it is possible to quantify the photon-number correlation coefficient between the components of a classical state described by non-trivial statistics and by a non-Gaussian Wigner function. The measurements, performed in the quite unexplored mesoscopic domain (up to 100 photons incident onto the detector), are in good agreement with the theoretical predictions, and thus open the possibility of performing further tests on this exotic state for its application in the field of quantum information.
Harnessing entanglement as a resource is the main workhorse of many quantum protocols, and establishing the degree of quantum correlations of quantum states is an important certification process that has to take place prior to any implementations of these quantum protocols. The emergence of photodetectors known as photon-number-resolving detectors (PNRDs) that allow for accounting of photon numbers simultaneously arriving at the detectors has led to the need for modeling accurately and applying them for use in the certification process. Here we study the variance of difference of photocounts (VDP) of two PNRDs, which is one measure of quantum correlations, under the effects of loss and saturation. We found that it would be possible to distinguish between the classical correlation of a two-mode coherent state and the quantum correlation of a twin-beam state within some photo count regime of the detector. We compare the behavior of two such PNRDs. The first for which the photocount statistics follow a binomial distribution accounting for losses, and the second is that of Agarwal, Vogel, and Sperling for which the incident beam is first split and then separately measured by ON/OFF detectors. In our calculations, analytical expressions are derived for the variance of difference where possible. In these cases, Gauss' hypergeometric function appears regularly, giving an insight to the type of quantum statistics the photon counting gives in these PNRDs. The different mechanisms of the two types of PNRDs leads to quantitative differences in their VDP.
By using hybrid photodetectors we exploited the photon-number correlations existing in bipartite optical states to demonstrate the effect of multiple-photon subtraction on the generation of conditional states in the pulsed regime. We operated on both classical and quantum Gaussian bipartite states in the mesoscopic regime without background subtraction and corrections. The obtained conditional states are non-Gaussian in nature, thus particularly useful for applications to Quantum Information. All the experimental results are in excellent agreement with theoretical models.
We measure high-order correlation functions of detected-photon numbers in the mesoscopic regime by means of hybrid photodetectors. The analytical expressions for correlations are evaluated in terms of quantities that can be experimentally accessed by a selfconsistent analysis of the detectors' outputs. We demonstrate that high-order correlations can be used to characterize the nature of the optical states, for instance by better discriminating between classical and quantum behavior even in critical situations, such as multimode twin-beam state. The results are in very good agreement with the theory, both for classical states and quantum states.