We analyze the Heisenberg limit on phase estimation for Gaussian states. In the analysis, no reference to a phase operator is made. We prove that the squeezed vacuum state is the most sensitive for a given average photon number. We provide two adaptive local measurement schemes that attain the Heisenberg limit asymptotically. One of them is described by a positive operator-valued measure and its efficiency is exhaustively explored. We also study Gaussian measurement schemes based on phase quadrature measurements. We show that homodyne tomography of the appropriate quadrature attains the Heisenberg limit for large samples. This proves that this limit can be attained with local projective von Neuman measurements.
We analyze the Heisenberg limit on phase estimation for Gaussian states. In the analysis, no reference to a phase operator is made. We prove that the squeezed vacuum state is the most sensitive for a given average photon number. We provide two adaptive local measurement schemes that attain the Heisenberg limit asymptotically. One of them is described by a positive operator-valued measure and its efficiency is exhaustively explored. We also study Gaussian measurement schemes based on phase quadrature measurements. We show that homodyne tomography of the appropriate quadrature attains the Heisenberg limit for large samples. This proves that this limit can be attained with local projective von Neuman measurements.
Phase estimation plays a central role in communications, sensing, and information processing. Quantum correlated states, such as squeezed states, enable phase estimation beyond the shot-noise limit, and in principle approach the ultimate quantum limit in precision, when paired with optimal quantum measurements. However, physical realizations of optimal quantum measurements for optical phase estimation with quantum-correlated states are still unknown. Here we address this problem by introducing an adaptive Gaussian measurement strategy for optical phase estimation with squeezed vacuum states that, by construction, approaches the quantum limit in precision. This strategy builds from a comprehensive set of locally optimal POVMs through rotations and homodyne measurements and uses the Adaptive Quantum State Estimation framework for optimizing the adaptive measurement process, which, under certain regularity conditions, guarantees asymptotic optimality for this quantum parameter estimation problem. As a result, the adaptive phase estimation strategy based on locally-optimal homodyne measurements achieves the quantum limit within the phase interval of [ 0 , π / 2 ) . Furthermore, we generalize this strategy by including heterodyne measurements, enabling phase estimation across the full range of phases from [ 0 , π ) , where squeezed vacuum allows for unambiguous phase encoding. Remarkably, for this phase interval, which is the maximum range of phases that can be encoded in squeezed vacuum, this estimation strategy maintains an asymptotic quantum-optimal performance, representing a significant advancement in quantum metrology.
We propose two-stage optimized strategies for full-period optical phase estimation with single-mode Gaussian states and Gaussian measurements under a fixed energy constraint. In the first stage (Stage I), displaced squeezed probes and heterodyne measurements provide coarse localization of the phase to a window on the circle. In the second stage (Stage II), squeezed-vacuum probes with adaptive homodyne measurements perform efficient phase estimation inside the selected window. We derive a generalized Cramér-Rao bound for this family of two-stage Gaussian strategies, which contains the contribution from local parameter estimation in Stage II plus an overshoot penalty from coarse localization errors in Stage I. For E <= 25 photons and squeezing limited to 12 dB, protocols using displaced squeezed states in Stage I reduce the optimized two-stage bound relative to protocols using coherent states in Stage I, and remain within a factor of 3 to 30 of the idealized local squeezed-vacuum quantum Cramér-Rao bound.
The ultimate precision of phase estimation is limited by the Heisenberg scaling Δϕ0=K/N, where K∼1 is a numerical prefactor and N is the mean number of photons interacting with the phase shifting object(s). However, achieving this fundamental limit often comes at the cost of an extremely narrow high-sensitive range, rendering schemes impractical. We analyze the precision limits of phase measurements in single- and two-arm optical interferometers with input Gaussian states. We consider two detection methods: conventional homodyne measurement and non-Gaussian threshold detection that saturates the quantum Cramér-Rao bound. We characterize the performance by two complementary metrics: the peak sensitivity Δϕ0 and the width δϕ of the high-sensitivity range. We demonstrate that Heisenberg scaling is attainable in all configurations considered. However, we reveal that δϕ strongly depends on K. We derive an approximate analytic expression that describes this trade-off. We show also that the two-arm interferometer with antisymmetrically squeezed inputs exhibits exceptional performance, simultaneously achieving Heisenberg-limited sensitivity and a broad high-sensitivity range δϕ=π/2.
The central issue in quantum parameter estimation is to find out the optimal measurement setup that leads to the ultimate lower bound of an estimation error. We address here a question of whether a Gaussian measurement scheme can achieve the ultimate bound for phase estimation in single-mode Gaussian metrology that exploits single-mode Gaussian probe states in a Gaussian environment. We identify three types of optimal Gaussian measurement setups yielding the maximal Fisher information depending on displacement, squeezing, and thermalization of the probe state. We show that the homodyne measurement attains the ultimate bound for both displaced thermal probe states and squeezed vacuum probe states, whereas for the other single-mode Gaussian probe states, the optimized Gaussian measurement cannot be the optimal setup, although they are sometimes nearly optimal. We then demonstrate that the measurement on the basis of the product quadrature operators XP+PX, i.e., a non-Gaussian measurement, is required to be fully optimal.
Abstract The central issue in quantum parameter estimation is to find out the optimal measurement setup that leads to the ultimate lower bound of an estimation error. We address here a question of whether a Gaussian measurement scheme can achieve the ultimate bound for phase estimation in single-mode Gaussian metrology that exploits single-mode Gaussian probe states in a Gaussian environment. We identify three types of optimal Gaussian measurement setups yielding the maximal Fisher information depending on displacement, squeezing, and thermalization of the probe state. We show that the homodyne measurement attains the ultimate bound for both displaced thermal probe states and squeezed vacuum probe states, whereas for the other single-mode Gaussian probe states, the optimized Gaussian measurement cannot be the optimal setup, although they are sometimes nearly optimal. We then demonstrate that the measurement on the basis of the product quadrature operators X^P^+P^X^ X ̂ P ̂ + P ̂ X ̂ , i.e., a non-Gaussian measurement, is required to be fully optimal.
The modern scientific method is critically dependent on precision measurements of physical parameters. A classic example is the measurement of the optical phase enabled by optical interferometry, where the error on the measured phase is conventionally bounded by the so-called Heisenberg limit. To achieve phase estimation at the Heisenberg limit, it has been common to consider protocols based on highly complex N00N states of light. However, despite decades of research and several experimental explorations, there has been no demonstration of deterministic phase estimation with N00N states reaching the Heisenberg limit or even surpassing the shot noise limit. Here we use a deterministic phase estimation scheme based on a source of Gaussian squeezed vacuum states and high-efficiency homodyne detection to obtain phase estimates with an extreme sensitivity that significantly surpasses the shot noise limit and even beats the conventional Heisenberg limit as well as the performance of a pure N00N state protocol. Using a high-efficiency setup with a total loss of about 11%, we achieve a Fisher information of 15.8(6) rad^{-2} per photon-a significant increase in performance compared to state of the art and beyond an ideal six photon N00N state scheme. This work represents an important achievement in quantum metrology, and it opens the door to future quantum sensing technologies for the interrogation of light-sensitive biological systems.