Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optimal Gaussian measurements for phase estimation in single-mode Gaussian metrology

Changhun Oh, Changhyoup Lee, Carsten Rockstuhl, Hyunseok Jeong, Jaewan Kim, Hyunchul Nha, Su‐Yong Lee

Published Jan 1, 2019• 65 citations
Publisher

Abstract

The central issue in quantum parameter estimation is to find out the optimal measurement setup that leads to the ultimate lower bound of an estimation error. We address here a question of whether a Gaussian measurement scheme can achieve the ultimate bound for phase estimation in single-mode Gaussian metrology that exploits single-mode Gaussian probe states in a Gaussian environment. We identify three types of optimal Gaussian measurement setups yielding the maximal Fisher information depending on displacement, squeezing, and thermalization of the probe state. We show that the homodyne measurement attains the ultimate bound for both displaced thermal probe states and squeezed vacuum probe states, whereas for the other single-mode Gaussian probe states, the optimized Gaussian measurement cannot be the optimal setup, although they are sometimes nearly optimal. We then demonstrate that the measurement on the basis of the product quadrature operators XP+PX, i.e., a non-Gaussian measurement, is required to be fully optimal.

DOI
10.5445/ir/1000091093

Related papers

Optimal Gaussian measurements for phase estimation in single-mode Gaussian metrology

Changhun Oh, Changhyoup Lee, Carsten Rockstuhl +4 more

Abstract The central issue in quantum parameter estimation is to find out the optimal measurement setup that leads to the ultimate lower bound of an estimation error. We address here a question of whether a Gaussian measurement scheme can achieve the ultimate bound for phase estimation in single-mode Gaussian metrology that exploits single-mode Gaussian probe states in a Gaussian environment. We identify three types of optimal Gaussian measurement setups yielding the maximal Fisher information depending on displacement, squeezing, and thermalization of the probe state. We show that the homodyne measurement attains the ultimate bound for both displaced thermal probe states and squeezed vacuum probe states, whereas for the other single-mode Gaussian probe states, the optimized Gaussian measurement cannot be the optimal setup, although they are sometimes nearly optimal. We then demonstrate that the measurement on the basis of the product quadrature operators $$\hat X\hat P + \hat P\hat X$$ X ̂ P ̂ + P ̂ X ̂ , i.e., a non-Gaussian measurement, is required to be fully optimal.

arXiv:1805.08495•npj Quantum Information•Jan 28, 2019•81 citations

Optimal Gaussian metrology for generic multimode interferometric circuit

Teruo Matsubara, Paolo Facchi A, Vittorio Giovannetti +1 more

Bounds on the ultimate precision attainable in the estimation of a parameter in Gaussian quantum metrology are obtained when the average number of bosonic probes is fixed.We identify the optimal input probe state among generic (mixed in general) Gaussian states with a fixed average number of probe photons for the estimation of a parameter contained in a generic multimode interferometric optical circuit, namely, a passive linear circuit preserving the total number of photons.The optimal Gaussian input state is essentially a single-mode squeezed vacuum, and the ultimate precision is achieved by a homodyne measurement on the single mode.We also reveal the best strategy for the estimation when we are given L identical target circuits and are allowed to apply passive linear controls in between with an arbitrary number of ancilla modes introduced.

arXiv:1802.01452•New Journal of Physics•Feb 11, 2019•32 citations

Knowledge-dependent optimal Gaussian strategies for phase estimation

Ricard Ravell Rodríguez, Simon Morelli

When estimating an unknown phase rotation of a continuous-variable system with homodyne detection, the optimal probe state strongly depends on the value of the estimated parameter. In this article, we identify the optimal pure single-mode Gaussian probe states depending on the knowledge of the estimated phase parameter before the measurement. We find that for a large prior uncertainty, the optimal probe states are close to coherent states, a result in line with findings from noisy parameter estimation. However, with increasingly precise estimates of the parameter, it becomes beneficial to put more of the available energy into the squeezing of the probe state. Surprisingly, there is a clear jump, where the optimal probe state changes abruptly to a squeezed vacuum state, which maximizes the Fisher information for this estimation task. We use our results to study repeated measurements and compare different methods to adapt the probe state based on the changing knowledge of the parameter according to the previous findings.

arXiv:2412.16023•SciPost Physics•May 27, 2025•0 citations

Full-Period Optical Phase Estimation with Heisenberg Scaling Using Displaced Squeezed States and Gaussian Measurements

Marco A. Rodríguez-García, Luis Medina-Dozal, Francisco E. Becerra

We propose two-stage optimized strategies for full-period optical phase estimation with single-mode Gaussian states and Gaussian measurements under a fixed energy constraint. In the first stage (Stage I), displaced squeezed probes and heterodyne measurements provide coarse localization of the phase to a window on the circle. In the second stage (Stage II), squeezed-vacuum probes with adaptive homodyne measurements perform efficient phase estimation inside the selected window. We derive a generalized Cramér-Rao bound for this family of two-stage Gaussian strategies, which contains the contribution from local parameter estimation in Stage II plus an overshoot penalty from coarse localization errors in Stage I. For E <= 25 photons and squeezing limited to 12 dB, protocols using displaced squeezed states in Stage I reduce the optimized two-stage bound relative to protocols using coherent states in Stage I, and remain within a factor of 3 to 30 of the idealized local squeezed-vacuum quantum Cramér-Rao bound.

quant-pharXiv:2607.02960•Jul 6, 2026•0 citations

Multiparameter Gaussian quantum metrology

Rosanna Nichols, Pietro Liuzzo-Scorpo, Paul A. Knott +1 more

We investigate the ultimate precision achievable in Gaussian quantum metrology. We derive general analytical expressions for the quantum Fisher information matrix and for the measurement compatibility condition, ensuring asymptotic saturability of the quantum Cram\'er-Rao bound, for the estimation of multiple parameters encoded in multimode Gaussian states. We then apply our results to the joint estimation of a phase shift and two parameters characterizing Gaussian phase covariant noise in optical interferometry. In such a scheme, we show that two-mode displaced squeezed input probes with optimally tuned squeezing and displacement fulfill the measurement compatibility condition and enable the simultaneous estimation of all three parameters, with an advantage over individual estimation schemes that quickly rises with increasing mean energy of the probes.

arXiv:1711.09132•Physical Review A•Jul 11, 2018•130 citations

Optimal measurements for quantum fidelity between Gaussian states and its relevance to quantum metrology

Changhun Oh, Changhyoup Lee, Leonardo Banchi +3 more

Quantum fidelity is a measure to quantify the closeness between two quantum states. In an operational sense, it is defined as the minimal overlap between the probability distributions of measurement outcomes and the minimum is taken over all possible positive-operator valued measures (POVMs). Quantum fidelity has been investigated in various scientific fields, but the identification of associated optimal measurements has often been overlooked despite its great importance both for fundamental interest and practical purposes. We find here the optimal POVMs for quantum fidelity between multimode Gaussian states in a closed analytical form. Our general finding is applied for selected single-mode Gaussian states of particular interest and we identify three types of optimal measurements: an excitation-number-resolving detection, a projection onto the eigenbasis of operator $\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{x}\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{p}+\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{p}\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{x}$, and a quadrature variable detection, each of which corresponds to distinct types of single-mode Gaussian states. We also show the equivalence between optimal measurements for quantum fidelity and those for quantum parameter estimation when two arbitrary states are infinitesimally close. It is applied for simplifying the derivations of quantum Fisher information and the associated optimal measurements, exemplified by displacement, phase, squeezing, and loss parameter estimation using Gaussian states.

arXiv:1901.02994•Physical Review A•Jul 16, 2019•37 citations
The central issue in quantum parameter estimation is to find out the optimal measurement setup that leads to the ultimate lower bound of an estimation error. We address here a question of whether a Gaussian measurement scheme can achieve the ultimate bound for phase estimation in single-mode Gaussian metrology that exploits single-mode Gaussian probe states in a Gaussian environment. We identify three types of optimal Gaussian measurement setups yielding the maximal Fisher information depending on displacement, squeezing, and thermalization of the probe state. We show that the homodyne measurement attains the ultimate bound for both displaced thermal probe states and squeezed vacuum probe states, whereas for the other single-mode Gaussian probe states, the optimized Gaussian measurement cannot be the optimal setup, although they are sometimes nearly optimal. We then demonstrate that the measurement on the basis of the product quadrature operators XP+PX, i.e., a non-Gaussian measurement, is required to be fully optimal.
Abstract The central issue in quantum parameter estimation is to find out the optimal measurement setup that leads to the ultimate lower bound of an estimation error. We address here a question of whether a Gaussian measurement scheme can achieve the ultimate bound for phase estimation in single-mode Gaussian metrology that exploits single-mode Gaussian probe states in a Gaussian environment. We identify three types of optimal Gaussian measurement setups yielding the maximal Fisher information depending on displacement, squeezing, and thermalization of the probe state. We show that the homodyne measurement attains the ultimate bound for both displaced thermal probe states and squeezed vacuum probe states, whereas for the other single-mode Gaussian probe states, the optimized Gaussian measurement cannot be the optimal setup, although they are sometimes nearly optimal. We then demonstrate that the measurement on the basis of the product quadrature operators X^P^+P^X^\hat X\hat P + \hat P\hat XX^P^+P^X^ X ̂ P ̂ + P ̂ X ̂ , i.e., a non-Gaussian measurement, is required to be fully optimal.
Bounds on the ultimate precision attainable in the estimation of a parameter in Gaussian quantum metrology are obtained when the average number of bosonic probes is fixed.We identify the optimal input probe state among generic (mixed in general) Gaussian states with a fixed average number of probe photons for the estimation of a parameter contained in a generic multimode interferometric optical circuit, namely, a passive linear circuit preserving the total number of photons.The optimal Gaussian input state is essentially a single-mode squeezed vacuum, and the ultimate precision is achieved by a homodyne measurement on the single mode.We also reveal the best strategy for the estimation when we are given L identical target circuits and are allowed to apply passive linear controls in between with an arbitrary number of ancilla modes introduced.
When estimating an unknown phase rotation of a continuous-variable system with homodyne detection, the optimal probe state strongly depends on the value of the estimated parameter. In this article, we identify the optimal pure single-mode Gaussian probe states depending on the knowledge of the estimated phase parameter before the measurement. We find that for a large prior uncertainty, the optimal probe states are close to coherent states, a result in line with findings from noisy parameter estimation. However, with increasingly precise estimates of the parameter, it becomes beneficial to put more of the available energy into the squeezing of the probe state. Surprisingly, there is a clear jump, where the optimal probe state changes abruptly to a squeezed vacuum state, which maximizes the Fisher information for this estimation task. We use our results to study repeated measurements and compare different methods to adapt the probe state based on the changing knowledge of the parameter according to the previous findings.
We propose two-stage optimized strategies for full-period optical phase estimation with single-mode Gaussian states and Gaussian measurements under a fixed energy constraint. In the first stage (Stage I), displaced squeezed probes and heterodyne measurements provide coarse localization of the phase to a window on the circle. In the second stage (Stage II), squeezed-vacuum probes with adaptive homodyne measurements perform efficient phase estimation inside the selected window. We derive a generalized Cramér-Rao bound for this family of two-stage Gaussian strategies, which contains the contribution from local parameter estimation in Stage II plus an overshoot penalty from coarse localization errors in Stage I. For E <= 25 photons and squeezing limited to 12 dB, protocols using displaced squeezed states in Stage I reduce the optimized two-stage bound relative to protocols using coherent states in Stage I, and remain within a factor of 3 to 30 of the idealized local squeezed-vacuum quantum Cramér-Rao bound.
We investigate the ultimate precision achievable in Gaussian quantum metrology. We derive general analytical expressions for the quantum Fisher information matrix and for the measurement compatibility condition, ensuring asymptotic saturability of the quantum Cram\'er-Rao bound, for the estimation of multiple parameters encoded in multimode Gaussian states. We then apply our results to the joint estimation of a phase shift and two parameters characterizing Gaussian phase covariant noise in optical interferometry. In such a scheme, we show that two-mode displaced squeezed input probes with optimally tuned squeezing and displacement fulfill the measurement compatibility condition and enable the simultaneous estimation of all three parameters, with an advantage over individual estimation schemes that quickly rises with increasing mean energy of the probes.
Quantum fidelity is a measure to quantify the closeness between two quantum states. In an operational sense, it is defined as the minimal overlap between the probability distributions of measurement outcomes and the minimum is taken over all possible positive-operator valued measures (POVMs). Quantum fidelity has been investigated in various scientific fields, but the identification of associated optimal measurements has often been overlooked despite its great importance both for fundamental interest and practical purposes. We find here the optimal POVMs for quantum fidelity between multimode Gaussian states in a closed analytical form. Our general finding is applied for selected single-mode Gaussian states of particular interest and we identify three types of optimal measurements: an excitation-number-resolving detection, a projection onto the eigenbasis of operator $\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{x}\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{p}+\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{p}\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{x}$, and a quadrature variable detection, each of which corresponds to distinct types of single-mode Gaussian states. We also show the equivalence between optimal measurements for quantum fidelity and those for quantum parameter estimation when two arbitrary states are infinitesimally close. It is applied for simplifying the derivations of quantum Fisher information and the associated optimal measurements, exemplified by displacement, phase, squeezing, and loss parameter estimation using Gaussian states.