Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0408135 · Physical Review Letters

Incoherent Coincidence Imaging and Its Applicability in X-ray Diffraction

Jing Cheng, Shensheng Han

Published Mar 4, 2004• 504 citations
arXivHTMLPDF

Abstract

Entangled-photon coincidence imaging is a method to nonlocally image an object by transmitting a pair of entangled photons through the object and a reference optical system, respectively. The image of the object can be extracted from the coincidence rate of these two photons. From a classical perspective, the image is proportional to the fourth-order correlation function of the wave field. Using classical statistical optics, we study a particular aspect of coincidence imaging with incoherent sources. As an application, we give a proposal to realize lensless Fourier-transform imaging, and discuss its applicability in x-ray diffraction.

DOI
10.1103/physrevlett.92.093903

Related papers

Quantum and Classical Coincidence Imaging

Ryan S. Bennink, Sean J. Bentley, Robert W. Boyd +1 more

Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.

Physical Review Letters•Jan 22, 2004•418 citations

“Two-Photon” Coincidence Imaging with a Classical Source

Ryan S. Bennink, Sean J. Bentley, Robert W. Boyd

Coincidence imaging is a technique that extracts an image of a test system from the statistics of photons transmitted by a reference system when the two systems are illuminated by a source possessing appropriate correlations. It has recently been argued that quantum entangled sources are necessary for the implementation of this technique. We show that this technique does not require entanglement, and we provide an experimental demonstration of coincidence imaging using a classical source. We further find that any kind of coincidence imaging technique which uses a "bucket" detector in the test arm is incapable of imaging phase-only objects, whether a classical or quantum source is employed.

Physical Review Letters•Aug 26, 2002•1,115 citations

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•3 citations

Quantum imaging

Milena D’Angelo, Yanhua H. Shih

Since the early days of quantum mechanics, physicists have been puzzled by the counterintuitive consequences of entanglement. Quantum imaging is one of the most intriguing effects exhibiting the typical nonlocal behavior of entangled states and has in fact stimulated an intense debate regarding fundamental issues of quantum theory. Recently, particular attention has been given to the possibility of simulating quantum imaging classically, that is, without entanglement. The study of quantum imaging has also lead to useful practical applications such as high precision nonlocal timing-positioning and quantum lithography, in which measurements may achieve resolution even beyond the classical limits. In this paper, we first introduce the concept of quantum imaging and emphasize its peculiar quantum nature through a set of inequalities derived from the historical argument of Einstein, Podolsky and Rosen (EPR). The EPR inequalities are the quantitative formulation of the very different physics governing entangled and separable systems. We show that two-photon imaging may achieve its fundamental limit only through nonlocal measurements realized on entangled photon pairs. Furthermore, we show that quantum imaging may be exploited to overcome the Rayleigh diffraction limit; this is the basic idea behind quantum lithography. Finally, we discuss the possibility of extending the coherent two-photon imaging typical of entangled photon pairs to incoherent coincidence imaging, by employing chaotic light. From an applicative viewpoint, chaotic radiation may represent the ideal candidate for mimicking quantum ghost imaging, provided adequate detection schemes are developed.

Laser Physics Letters•Sep 16, 2005•132 citations

Coincidence fractional Fourier transform with entangled photon pairs and incoherent light

Yangjian Cai, Qiang Lin, Shi‐Yao Zhu

The coincidence fractional Fourier transforms with entangled photon pairs and with incoherent light are introduced. Optical systems for implementing the two coincidence fractional Fourier transforms are designed. The difference between the two coincidence fractional Fourier transforms is discussed.

Applied Physics Letters•Jan 5, 2005•26 citations

Resolution and apodization in images generated by twin photons

Ivan F. Santos, M. A. Sagioro, Carlos Henrique Monken +1 more

We show that an image of an object is obtained when at least one of the photons of a parametric down-converted pair illuminates the object and the two photons are detected in coincidence after they have been transmitted by two lenses. The image is mathematically described by a quantum fourth-order correlation function that differs from the classical image description in two aspects. The quantum image is produced by a nonlocal effective lens whose aperture is described by a compressed convolution of the magnitude of lens transmission functions. The image is generated by the entangled state two-photon light source in which the effective wavelength is equal to the de Broglie wavelength $\ensuremath{\lambda}/2,$ where $\ensuremath{\lambda}$ is the wavelength associated to the individual photons. Images can be obtained with a resolution better than the obtained with coherent classical light sources. Better resolution and strong apodization effects are observed.

Physical Review A•Mar 26, 2003•30 citations
Entangled-photon coincidence imaging is a method to nonlocally image an object by transmitting a pair of entangled photons through the object and a reference optical system, respectively. The image of the object can be extracted from the coincidence rate of these two photons. From a classical perspective, the image is proportional to the fourth-order correlation function of the wave field. Using classical statistical optics, we study a particular aspect of coincidence imaging with incoherent sources. As an application, we give a proposal to realize lensless Fourier-transform imaging, and discuss its applicability in x-ray diffraction.
Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.
Coincidence imaging is a technique that extracts an image of a test system from the statistics of photons transmitted by a reference system when the two systems are illuminated by a source possessing appropriate correlations. It has recently been argued that quantum entangled sources are necessary for the implementation of this technique. We show that this technique does not require entanglement, and we provide an experimental demonstration of coincidence imaging using a classical source. We further find that any kind of coincidence imaging technique which uses a "bucket" detector in the test arm is incapable of imaging phase-only objects, whether a classical or quantum source is employed.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
Since the early days of quantum mechanics, physicists have been puzzled by the counterintuitive consequences of entanglement. Quantum imaging is one of the most intriguing effects exhibiting the typical nonlocal behavior of entangled states and has in fact stimulated an intense debate regarding fundamental issues of quantum theory. Recently, particular attention has been given to the possibility of simulating quantum imaging classically, that is, without entanglement. The study of quantum imaging has also lead to useful practical applications such as high precision nonlocal timing-positioning and quantum lithography, in which measurements may achieve resolution even beyond the classical limits. In this paper, we first introduce the concept of quantum imaging and emphasize its peculiar quantum nature through a set of inequalities derived from the historical argument of Einstein, Podolsky and Rosen (EPR). The EPR inequalities are the quantitative formulation of the very different physics governing entangled and separable systems. We show that two-photon imaging may achieve its fundamental limit only through nonlocal measurements realized on entangled photon pairs. Furthermore, we show that quantum imaging may be exploited to overcome the Rayleigh diffraction limit; this is the basic idea behind quantum lithography. Finally, we discuss the possibility of extending the coherent two-photon imaging typical of entangled photon pairs to incoherent coincidence imaging, by employing chaotic light. From an applicative viewpoint, chaotic radiation may represent the ideal candidate for mimicking quantum ghost imaging, provided adequate detection schemes are developed.
We show that an image of an object is obtained when at least one of the photons of a parametric down-converted pair illuminates the object and the two photons are detected in coincidence after they have been transmitted by two lenses. The image is mathematically described by a quantum fourth-order correlation function that differs from the classical image description in two aspects. The quantum image is produced by a nonlocal effective lens whose aperture is described by a compressed convolution of the magnitude of lens transmission functions. The image is generated by the entangled state two-photon light source in which the effective wavelength is equal to the de Broglie wavelength $\ensuremath{\lambda}/2,$ where $\ensuremath{\lambda}$ is the wavelength associated to the individual photons. Images can be obtained with a resolution better than the obtained with coherent classical light sources. Better resolution and strong apodization effects are observed.