Entangled-photon coincidence imaging is a method to nonlocally image an object by transmitting a pair of entangled photons through the object and a reference optical system, respectively. The image of the object can be extracted from the coincidence rate of these two photons. From a classical perspective, the image is proportional to the fourth-order correlation function of the wave field. Using classical statistical optics, we study a particular aspect of coincidence imaging with incoherent sources. As an application, we give a proposal to realize lensless Fourier-transform imaging, and discuss its applicability in x-ray diffraction.
Entangled-photon coincidence imaging is a method to nonlocally image an object by transmitting a pair of entangled photons through the object and a reference optical system, respectively. The image of the object can be extracted from the coincidence rate of these two photons. From a classical perspective, the image is proportional to the fourth-order correlation function of the wave field. Using classical statistical optics, we study a particular aspect of coincidence imaging with incoherent sources. As an application, we give a proposal to realize lensless Fourier-transform imaging, and discuss its applicability in x-ray diffraction.
Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.
Coincidence imaging is a technique that extracts an image of a test system from the statistics of photons transmitted by a reference system when the two systems are illuminated by a source possessing appropriate correlations. It has recently been argued that quantum entangled sources are necessary for the implementation of this technique. We show that this technique does not require entanglement, and we provide an experimental demonstration of coincidence imaging using a classical source. We further find that any kind of coincidence imaging technique which uses a "bucket" detector in the test arm is incapable of imaging phase-only objects, whether a classical or quantum source is employed.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
Since the early days of quantum mechanics, physicists have been puzzled by the counterintuitive consequences of entanglement. Quantum imaging is one of the most intriguing effects exhibiting the typical nonlocal behavior of entangled states and has in fact stimulated an intense debate regarding fundamental issues of quantum theory. Recently, particular attention has been given to the possibility of simulating quantum imaging classically, that is, without entanglement. The study of quantum imaging has also lead to useful practical applications such as high precision nonlocal timing-positioning and quantum lithography, in which measurements may achieve resolution even beyond the classical limits. In this paper, we first introduce the concept of quantum imaging and emphasize its peculiar quantum nature through a set of inequalities derived from the historical argument of Einstein, Podolsky and Rosen (EPR). The EPR inequalities are the quantitative formulation of the very different physics governing entangled and separable systems. We show that two-photon imaging may achieve its fundamental limit only through nonlocal measurements realized on entangled photon pairs. Furthermore, we show that quantum imaging may be exploited to overcome the Rayleigh diffraction limit; this is the basic idea behind quantum lithography. Finally, we discuss the possibility of extending the coherent two-photon imaging typical of entangled photon pairs to incoherent coincidence imaging, by employing chaotic light. From an applicative viewpoint, chaotic radiation may represent the ideal candidate for mimicking quantum ghost imaging, provided adequate detection schemes are developed.
To obtain spatial information about an arbitrary atomic distribution in x-ray structure analysis, e.g. in molecules or proteins, the standard method is to measure the intensity in the far field, i.e. the first-order photon correlation function of the coherently scattered x-ray photons (coherent diffractive imaging). Recently, it was suggested to record alternatively the incoherently scattered photons and measure the second-order photon correlation function to reconstruct the geometry of the unknown atomic distribution (incoherent diffractive imaging). Yet, besides various advantages of the latter method, both techniques suffer from the so-called phase retrieval problem. Lately, an ab-initio phase retrieval algorithm to reconstruct the phase of the so-called structure factor of the scattering objects based on the third-order photon correlation function was reported. The algorithm makes use of the closure phase, which contains important, yet incomplete phase information, well-known from triple correlations and their bispectrum in speckle masking and astronomy applications. Here, we provide a detailed analysis of the underlying scheme and quantities in the context of x-ray structure analysis. In particular, we explicitly calculate for the first time the third-order photon correlation function for single photon emitters in a full quantum mechanical treatment and discuss the uniqueness of the closure phase equations constructed from. In this context, we recapitulate the sign problem of the closure phase and how it can be lifted using redundant information. We further show how the algorithm can be improved using even higher-order photon correlation functions produced by single photon emitters, e.g. the fourth-order correlation function, delivering new phase relations appearing in the four-point correlations.