Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2312.12168 · New Journal of Physics

Phase retrieval in incoherent diffractive imaging using higher-order photon correlation functions

Manuel Bojer, J Eckert, Sebastian Karl, S Richter, Joachim von Zanthier

Published Jun 1, 2024• 3 citations
arXivHTMLPDF

Abstract

To obtain spatial information about an arbitrary atomic distribution in x-ray structure analysis, e.g. in molecules or proteins, the standard method is to measure the intensity in the far field, i.e. the first-order photon correlation function of the coherently scattered x-ray photons (coherent diffractive imaging). Recently, it was suggested to record alternatively the incoherently scattered photons and measure the second-order photon correlation function to reconstruct the geometry of the unknown atomic distribution (incoherent diffractive imaging). Yet, besides various advantages of the latter method, both techniques suffer from the so-called phase retrieval problem. Lately, an ab-initio phase retrieval algorithm to reconstruct the phase of the so-called structure factor of the scattering objects based on the third-order photon correlation function was reported. The algorithm makes use of the closure phase, which contains important, yet incomplete phase information, well-known from triple correlations and their bispectrum in speckle masking and astronomy applications. Here, we provide a detailed analysis of the underlying scheme and quantities in the context of x-ray structure analysis. In particular, we explicitly calculate for the first time the third-order photon correlation function for single photon emitters in a full quantum mechanical treatment and discuss the uniqueness of the closure phase equations constructed from. In this context, we recapitulate the sign problem of the closure phase and how it can be lifted using redundant information. We further show how the algorithm can be improved using even higher-order photon correlation functions produced by single photon emitters, e.g. the fourth-order correlation function, delivering new phase relations appearing in the four-point correlations.

DOI
10.1088/1367-2630/ad5227

Related papers

Ab initio spatial phase retrieval via intensity triple correlations

Nolan Peard, Kartik Ayyer, Henry N. Chapman

Second-order intensity correlations from incoherent emitters can reveal the Fourier transform modulus of their spatial distribution, but retrieving the phase to enable completely general Fourier inversion to real space remains challenging. Phase retrieval via the third-order intensity correlations has relied on special emitter configurations which simplified an unaddressed sign problem in the computation. Without a complete treatment of this sign problem, the general case of retrieving the Fourier phase from a truly arbitrary configuration of emitters is not possible. In this paper, a general method for ab initio phase retrieval via the intensity triple correlations is described. Simulations demonstrate accurate phase retrieval for clusters of incoherent emitters which could be applied to imaging stars or fluorescent atoms and molecules. With this work, it is now finally tractable to perform Fourier inversion directly and reconstruct images of arbitrary arrays of independent emitters via far-field intensity correlations alone.

arXiv:2210.03793•Optics Express•Jul 13, 2023•4 citations

Quantum enhanced phase retrieval

Liat Liberman, Yonatan Israel, Eilon Poem +1 more

The retrieval of phases from intensity measurements is a key process in many fields in science, from optical microscopy to x-ray crystallography. Here we study phase retrieval of a one-dimensional multi-phase object that is illuminated by quantum states of light. We generalize the iterative Gerchberg-Saxton algorithm to photon correlation measurements on the output plane, rather than the standard intensity measurements. We report a numerical comparison of classical and quantum phase retrieval of a small one-dimensional object of discrete phases from its far-field diffraction. While the classical algorithm was ambiguous and often converged to wrong solutions, quantum light produced a unique reconstruction with smaller errors and faster convergence. We attribute these improvements to a larger Hilbert space that constrains the algorithm.

arXiv:1506.09198•Optica•Feb 16, 2016•17 citations

Incoherent Coincidence Imaging and Its Applicability in X-ray Diffraction

Jing Cheng, Shensheng Han

Entangled-photon coincidence imaging is a method to nonlocally image an object by transmitting a pair of entangled photons through the object and a reference optical system, respectively. The image of the object can be extracted from the coincidence rate of these two photons. From a classical perspective, the image is proportional to the fourth-order correlation function of the wave field. Using classical statistical optics, we study a particular aspect of coincidence imaging with incoherent sources. As an application, we give a proposal to realize lensless Fourier-transform imaging, and discuss its applicability in x-ray diffraction.

arXiv:quant-ph/0408135•Physical Review Letters•Mar 4, 2004•539 citations

Analysis and measurement of high-order photon correlations of light fields

Yanqiang Guo, Lijing Wang, Yu Wang +3 more

High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.

Acta Physica Sinica•Jan 1, 2020•5 citations

Quantum enhanced non-interferometric quantitative phase imaging

Giuseppe Ortolano, Alberto Paniate, Pauline Boucher +5 more

Quantum entanglement and squeezing have significantly improved phase estimation and imaging in interferometric settings beyond the classical limits. However, for a wide class of non-interferometric phase imaging/retrieval methods vastly used in the classical domain, e.g., ptychography and diffractive imaging, a demonstration of quantum advantage is still missing. Here, we fill this gap by exploiting entanglement to enhance imaging of a pure phase object in a non-interferometric setting, only measuring the phase effect on the free-propagating field. This method, based on the so-called "transport of intensity equation", is quantitative since it provides the absolute value of the phase without prior knowledge of the object and operates in wide-field mode, so it does not need time-consuming raster scanning. Moreover, it does not require spatial and temporal coherence of the incident light. Besides a general improvement of the image quality at a fixed number of photons irradiated through the object, resulting in better discrimination of small details, we demonstrate a clear reduction of the uncertainty in the quantitative phase estimation. Although we provide an experimental demonstration of a specific scheme in the visible spectrum, this research also paves the way for applications at different wavelengths, e.g., X-ray imaging, where reducing the photon dose is of utmost importance.

arXiv:2304.14727•Light Science & Applications•Jul 11, 2023•60 citations

Phase retrieval enhanced by quantum correlation

Giuseppe Ortolano, Pauline Boucher, Ivano Ruo Berchera +2 more

Quantum correlation, such as entanglement and squeezing have shown to improve phase estimation in interferometric setups on one side, and non-interferometric imaging scheme of amplitude object on the other. In the last case, quantum correlation among a pair of beams leads to a sub-shot-noise readout of the image intensity pattern, where weak details, otherwise hidden in the noise, can be appreciated. In this paper we propose a technique which exploits entanglement to enhance quantitative phase retrieval of an object in a non-interferometric setting, i.e only measuring the propagated intensity pattern after interaction with the object. The method exploits existing technology, it operates in wide field mode, so does not require time consuming raster scanning and can operate with small spatial coherence of the incident field. This protocol can find application in optical microscopy and X-ray imaging, reducing the photon dose necessary to achieve a fixed signal-to-noise ratio.

arXiv:2109.10095•Sep 21, 2021•1 citation
To obtain spatial information about an arbitrary atomic distribution in x-ray structure analysis, e.g. in molecules or proteins, the standard method is to measure the intensity in the far field, i.e. the first-order photon correlation function of the coherently scattered x-ray photons (coherent diffractive imaging). Recently, it was suggested to record alternatively the incoherently scattered photons and measure the second-order photon correlation function to reconstruct the geometry of the unknown atomic distribution (incoherent diffractive imaging). Yet, besides various advantages of the latter method, both techniques suffer from the so-called phase retrieval problem. Lately, an ab-initio phase retrieval algorithm to reconstruct the phase of the so-called structure factor of the scattering objects based on the third-order photon correlation function was reported. The algorithm makes use of the closure phase, which contains important, yet incomplete phase information, well-known from triple correlations and their bispectrum in speckle masking and astronomy applications. Here, we provide a detailed analysis of the underlying scheme and quantities in the context of x-ray structure analysis. In particular, we explicitly calculate for the first time the third-order photon correlation function for single photon emitters in a full quantum mechanical treatment and discuss the uniqueness of the closure phase equations constructed from. In this context, we recapitulate the sign problem of the closure phase and how it can be lifted using redundant information. We further show how the algorithm can be improved using even higher-order photon correlation functions produced by single photon emitters, e.g. the fourth-order correlation function, delivering new phase relations appearing in the four-point correlations.
Second-order intensity correlations from incoherent emitters can reveal the Fourier transform modulus of their spatial distribution, but retrieving the phase to enable completely general Fourier inversion to real space remains challenging. Phase retrieval via the third-order intensity correlations has relied on special emitter configurations which simplified an unaddressed sign problem in the computation. Without a complete treatment of this sign problem, the general case of retrieving the Fourier phase from a truly arbitrary configuration of emitters is not possible. In this paper, a general method for ab initio phase retrieval via the intensity triple correlations is described. Simulations demonstrate accurate phase retrieval for clusters of incoherent emitters which could be applied to imaging stars or fluorescent atoms and molecules. With this work, it is now finally tractable to perform Fourier inversion directly and reconstruct images of arbitrary arrays of independent emitters via far-field intensity correlations alone.
The retrieval of phases from intensity measurements is a key process in many fields in science, from optical microscopy to x-ray crystallography. Here we study phase retrieval of a one-dimensional multi-phase object that is illuminated by quantum states of light. We generalize the iterative Gerchberg-Saxton algorithm to photon correlation measurements on the output plane, rather than the standard intensity measurements. We report a numerical comparison of classical and quantum phase retrieval of a small one-dimensional object of discrete phases from its far-field diffraction. While the classical algorithm was ambiguous and often converged to wrong solutions, quantum light produced a unique reconstruction with smaller errors and faster convergence. We attribute these improvements to a larger Hilbert space that constrains the algorithm.
Entangled-photon coincidence imaging is a method to nonlocally image an object by transmitting a pair of entangled photons through the object and a reference optical system, respectively. The image of the object can be extracted from the coincidence rate of these two photons. From a classical perspective, the image is proportional to the fourth-order correlation function of the wave field. Using classical statistical optics, we study a particular aspect of coincidence imaging with incoherent sources. As an application, we give a proposal to realize lensless Fourier-transform imaging, and discuss its applicability in x-ray diffraction.
High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.
Quantum entanglement and squeezing have significantly improved phase estimation and imaging in interferometric settings beyond the classical limits. However, for a wide class of non-interferometric phase imaging/retrieval methods vastly used in the classical domain, e.g., ptychography and diffractive imaging, a demonstration of quantum advantage is still missing. Here, we fill this gap by exploiting entanglement to enhance imaging of a pure phase object in a non-interferometric setting, only measuring the phase effect on the free-propagating field. This method, based on the so-called "transport of intensity equation", is quantitative since it provides the absolute value of the phase without prior knowledge of the object and operates in wide-field mode, so it does not need time-consuming raster scanning. Moreover, it does not require spatial and temporal coherence of the incident light. Besides a general improvement of the image quality at a fixed number of photons irradiated through the object, resulting in better discrimination of small details, we demonstrate a clear reduction of the uncertainty in the quantitative phase estimation. Although we provide an experimental demonstration of a specific scheme in the visible spectrum, this research also paves the way for applications at different wavelengths, e.g., X-ray imaging, where reducing the photon dose is of utmost importance.
Quantum correlation, such as entanglement and squeezing have shown to improve phase estimation in interferometric setups on one side, and non-interferometric imaging scheme of amplitude object on the other. In the last case, quantum correlation among a pair of beams leads to a sub-shot-noise readout of the image intensity pattern, where weak details, otherwise hidden in the noise, can be appreciated. In this paper we propose a technique which exploits entanglement to enhance quantitative phase retrieval of an object in a non-interferometric setting, i.e only measuring the propagated intensity pattern after interaction with the object. The method exploits existing technology, it operates in wide field mode, so does not require time consuming raster scanning and can operate with small spatial coherence of the incident field. This protocol can find application in optical microscopy and X-ray imaging, reducing the photon dose necessary to achieve a fixed signal-to-noise ratio.