Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0610253 · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

All-optical atomic magnetometers based on nonlinear magneto-optical rotation with amplitude modulated light

Szymon Pustelny, Adam M. Wojciechowski, M. Kotyrba, Krystian Sycz, Jerzy Zachorowski, Wojciech Gawlik, A. Cingöz, N. Leefer, James Higbie, Eric Corsini, M. P. Ledbetter, Simon Rochester, Alexander O. Sushkov, Dmitry Budker

Published Mar 2, 2007• 5 citations
arXivHTMLPDF

Abstract

We demonstrate a magnetometric technique based on nonlinear magneto-optical rotation using amplitude modulated light. The magnetometers can be operated in either open-loop (typical nonlinear magneto-optical rotation with amplitude-modulated light) or closed-loop (self-oscillating) modes. The latter mode is particularly well suited for conditions where the magnetic field is changing by large amounts over a relatively short timescale.

DOI
10.1117/12.726794

Related papers

Optical atomic magnetometer

Dmitry Budker

An optical atomic magnetometers is provided operating on the principles of nonlinear magneto-optical rotation. An atomic vapor is optically pumped using linearly polarized modulated light. The vapor is then probed using a non-modulated linearly polarized light beam. The resulting modulation in polarization angle of the probe light is detected and used in a feedback loop to induce self-oscillation at the resonant frequency.

•Jan 23, 2023•0 citations

Self-oscillating rubidium magnetometer using nonlinear magneto-optical rotation

Peter D. D. Schwindt, Leo W. Hollberg, John E. Kitching

The detection of nonlinear magneto-optical rotation (NMOR) of polarized light through alkali atomic vapor is a highly sensitive technique for measuring magnetic fields. We demonstrate that when using frequency modulated light to excite the NMOR resonance, it is possible to cause the system to self-oscillate. The NMOR signal is not a simple replica of the sine wave modulation of the light, but rather contains many higher harmonics of the modulation frequency, and we implement two ways of processing the signal to recover the fundamental modulation frequency in the feedback loop and induce self-oscillation. Self-oscillation simplifies and reduces the power consumption of the electronics required to operate a magnetometer, making the NMOR technique attractive for commercialized magnetic sensors.

Review of Scientific Instruments•Dec 1, 2005•57 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•6 citations

Improving sensitivity of an amplitude-modulated magneto-optical atomic magnetometer using squeezed light

Jiahui Li, Irina V. Novikova

We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent probe field under identical conditions. To realize an all-atomic magnetometer prototype, we utilize a nonlinear atomic interaction, known as polarization self-rotation, to produce a squeezed probe field. An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields. While the overall sensitivity of the magnetometer is rather low ( > 250 p T / H z ), we clearly observe a 15 % sensitivity improvement when the squeezed probe is used. Our observations confirm the recently reported quantum enhancement in a modulated atomic magnetometer [ Phys. Rev. Lett. 127 , 193601 ( 2021 ) PRLTAO 0031-9007 10.1103/PhysRevLett.127.193601 ].

arXiv:2207.12962•Journal of the Optical Society of America B•Oct 5, 2022•15 citations

Nonlinear magneto-optical rotation with frequency-modulated light

Dmitry Budker, Derek F. Jackson Kimball, Valeriy V. Yashchuk +1 more

A magnetometric technique is demonstrated that may be suitable for precision measurements of fields ranging from the submicrogauss level to above the earth field. It is based on resonant nonlinear magneto-optical rotation caused by atoms contained in a vapor cell with antirelaxation wall coating. Linearly polarized, frequency-modulated laser light is used for optical pumping and probing. If the time-dependent optical rotation is measured at the first harmonic of the modulation frequency, ultra-narrow (\ensuremath{\sim} a few hertz) resonances are observed at near-zero magnetic fields, and at fields where the Larmor frequency coincides with half the light modulation frequency. Upon optimization, the sensitivity of the technique is expected to exceed ${10}^{\ensuremath{-}11} G/\sqrt{\mathrm{Hz}}.$

arXiv:physics/0201025•Physical Review A•May 2, 2002•139 citations

Nonlinear magneto-optical rotation with modulated light in tilted magnetic fields

Szymon Pustelny, Wojciech Gawlik, Simon Rochester +3 more

Larmor precession of laser-polarized atoms contained in antirelaxation-coated cells, detected via nonlinear magneto-optical rotation (NMOR), is a promising technique for a new generation of ultrasensitive atomic magnetometers. For magnetic fields directed along the light propagation direction, resonances in NMOR appear when linearly polarized light is frequency or amplitude modulated at twice the Larmor frequency. Because the frequency of these resonances depends on the magnitude but not the direction of the field, they are useful for scalar magnetometry. Additional NMOR resonances at the Larmor frequency appear when the magnetic field is tilted away from the light propagation direction in the plane defined by the light propagation and polarization vectors. These resonances, studied both experimentally and with a density matrix calculation in the present work, offer a convenient method of achieving additional information about a direction of the magnetic field.

arXiv:physics/0606257•Physical Review A•Dec 29, 2006•56 citations
We demonstrate a magnetometric technique based on nonlinear magneto-optical rotation using amplitude modulated light. The magnetometers can be operated in either open-loop (typical nonlinear magneto-optical rotation with amplitude-modulated light) or closed-loop (self-oscillating) modes. The latter mode is particularly well suited for conditions where the magnetic field is changing by large amounts over a relatively short timescale.
The detection of nonlinear magneto-optical rotation (NMOR) of polarized light through alkali atomic vapor is a highly sensitive technique for measuring magnetic fields. We demonstrate that when using frequency modulated light to excite the NMOR resonance, it is possible to cause the system to self-oscillate. The NMOR signal is not a simple replica of the sine wave modulation of the light, but rather contains many higher harmonics of the modulation frequency, and we implement two ways of processing the signal to recover the fundamental modulation frequency in the feedback loop and induce self-oscillation. Self-oscillation simplifies and reduces the power consumption of the electronics required to operate a magnetometer, making the NMOR technique attractive for commercialized magnetic sensors.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent probe field under identical conditions. To realize an all-atomic magnetometer prototype, we utilize a nonlinear atomic interaction, known as polarization self-rotation, to produce a squeezed probe field. An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields. While the overall sensitivity of the magnetometer is rather low ( > 250 p T / H z ), we clearly observe a 15 % sensitivity improvement when the squeezed probe is used. Our observations confirm the recently reported quantum enhancement in a modulated atomic magnetometer [ Phys. Rev. Lett. 127 , 193601 ( 2021 ) PRLTAO 0031-9007 10.1103/PhysRevLett.127.193601 ].
A magnetometric technique is demonstrated that may be suitable for precision measurements of fields ranging from the submicrogauss level to above the earth field. It is based on resonant nonlinear magneto-optical rotation caused by atoms contained in a vapor cell with antirelaxation wall coating. Linearly polarized, frequency-modulated laser light is used for optical pumping and probing. If the time-dependent optical rotation is measured at the first harmonic of the modulation frequency, ultra-narrow (\ensuremath{\sim} a few hertz) resonances are observed at near-zero magnetic fields, and at fields where the Larmor frequency coincides with half the light modulation frequency. Upon optimization, the sensitivity of the technique is expected to exceed ${10}^{\ensuremath{-}11} G/\sqrt{\mathrm{Hz}}.$
Larmor precession of laser-polarized atoms contained in antirelaxation-coated cells, detected via nonlinear magneto-optical rotation (NMOR), is a promising technique for a new generation of ultrasensitive atomic magnetometers. For magnetic fields directed along the light propagation direction, resonances in NMOR appear when linearly polarized light is frequency or amplitude modulated at twice the Larmor frequency. Because the frequency of these resonances depends on the magnitude but not the direction of the field, they are useful for scalar magnetometry. Additional NMOR resonances at the Larmor frequency appear when the magnetic field is tilted away from the light propagation direction in the plane defined by the light propagation and polarization vectors. These resonances, studied both experimentally and with a density matrix calculation in the present work, offer a convenient method of achieving additional information about a direction of the magnetic field.