Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0501679 · Physical Review B

Flux qubits and readout device with two independent flux lines

B. L. T. Plourde, Timothy L. Robertson, P. A. Reichardt, T. Hime, S. Linzen, C.-E. Wu, John L. Clarke

Published Aug 17, 2005• 80 citations
arXivHTMLPDF

Abstract

We report measurements on two superconducting flux qubits coupled to a readout superconducting quantum interference device (SQUID). Two on-chip flux bias lines allow independent flux control of any two of the three elements, as illustrated by a two-dimensional qubit flux map. The application of microwaves yields a frequency-flux dispersion curve for 1- and 2-photon driving of the single-qubit excited state, and coherent manipulation of the single-qubit state results in Rabi oscillations and Ramsey fringes. This architecture should be scalable to many qubits and SQUIDs on a single chip.

DOI
10.1103/physrevb.72.060506

Related papers

Spectroscopy and coherent manipulation of single and coupled flux qubits

Yulin Wu, Hui Deng, Keqiang Huang +7 more

Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time T Rabi = 78 ns and energy relaxation time T 1 = 315 ns. We found that the value of T Rabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.

Chinese Physics B•Sep 1, 2013•3 citations

Dispersive readout of a flux qubit at the single-photon level

Jedediah E Johnson, Emile Hoskinson, Chris Macklin +3 more

A superconducting flux qubit is inductively coupled to a superconducting quantum interference device (SQUID) magnetometer, capacitively shunted to form a 1.294-GHz resonator. The qubit-state-dependent resonator frequency is weakly probed with a microwave signal and detected with a microstrip SQUID amplifier. At a mean resonator occupation $\overline{n}=1.5$ photons, the readout visibility is increased by a factor of 4.5 over that using a cryogenic semiconductor amplifier. As $\overline{n}$ is increased from 0.008 to 0.1, no reduction in ${T}_{1}$ is observed, potentially enabling continuous monitoring of the qubit state.

arXiv:1109.2858•Physical Review B•Dec 15, 2011•20 citations

Readout of a qubit array via a single transmission line

Markus Jerger, Stefano Poletto, P. Macha +4 more

Frequency-selective readout for superconducting qubits opens up the way towards scaling qubit circuits without increasing the number of measurement lines. Here we demonstrate the readout of an array of 7 flux qubits located on the same chip using a single measurement line. Each qubit is placed near an individual λ/4 resonator which, in turn, is coupled to a common microwave transmission line. We performed spectroscopy and coherent manipulation of all qubits and determined their parameters in a single measurement run.

arXiv:1102.0404•Europhysics Letters (EPL)•Nov 1, 2011•28 citations

Microwave readout scheme for a Josephson phase qubit

Tobias Wirth, Jürgen Lisenfeld, Alexander V. Lukashenko +1 more

We present experimental results on a microwave scheme for reading out a Josephson phase qubit. A capacitively shunted superconducting quantum interference device (SQUID) is used as a nonlinear resonator which is inductively coupled to the qubit. The flux state of the qubit is detected by measuring the amplitude and phase of a microwave pulse reflected from the SQUID resonator. By this low-dissipative method, the qubit state measurement time is reduced to 25 μs, which is much faster than the conventional readout performed by switching the SQUID to its nonzero dc voltage state. The readout scheme presented here allows for reading out multiple qubits using a single microwave line by employing frequency-division multiplexing.

arXiv:1010.0954•Applied Physics Letters•Dec 27, 2010•13 citations

Coherent Quantum Dynamics of a Superconducting Flux Qubit

I. Chiorescu, Yasunobu Nakamura, C. J. P. M. Harmans +1 more

We have observed coherent time evolution between two quantum states of a superconducting flux qubit comprising three Josephson junctions in a loop. The superposition of the two states carrying opposite macroscopic persistent currents is manipulated by resonant microwave pulses. Readout by means of switching-event measurement with an attached superconducting quantum interference device revealed quantum-state oscillations with high fidelity. Under strong microwave driving, it was possible to induce hundreds of coherent oscillations. Pulsed operations on this first sample yielded a relaxation time of 900 nanoseconds and a free-induction dephasing time of 20 nanoseconds. These results are promising for future solid-state quantum computing.

arXiv:cond-mat/0305461•Science•Mar 20, 2003•1,216 citations

Optimization of superconducting flux qubit readout using near-quantum-limited amplifiers - eScholarship

Jedediah E Johnson

Though superconducting qubits offer the potential for a scalable quantum computing architecture, the high-fidelity readout necessary to execute practical algorithms has thus far remained elusive. Moreover, achievements toward high fidelity have been accompanied by either long measurement times or demolition of the quantum state. In this dissertation, we address these issues with the novel integration of two ultralow-noise, superconducting amplifiers into separate dispersive flux qubit measurements. We first demonstrate a flux qubit inductively coupled to a 1.294-GHz nonlinear oscillator formed by a capacitively shunted DC SQUID. The frequency of the oscillator is modulated by the state of the qubit and is detected via microwave reflectometry. A microstrip SQUID (Superconducting QUantum Interference Device) amplifier (MSA) is used to increase the sensitivity of the measurement over that of a semiconductor amplifier. In the second experiment, we report measurements of a flux qubit coupled via a shared inductance to a quasi-lumped element 5.78-GHz readout resonator formed by the parallel combination of an interdigitated capacitor and a meander line inductor. The system noise is substantially reduced by a near-quantum-limited Josephson parametric amplifier (paramp).We present measurements of increased fidelity and reduced measurement backaction using the MSA at readout excitation levels as low as one hundredth of a photon in the readout resonator, observing a 4.5-fold increase in the readout visibility. Furthermore, at low readout excitation levels below one tenth of a photon in the readout resonator, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state. Using the paramp, we demonstrate a continuous, high-fidelity readout with sufficient bandwidth and signal-to-noise ratio to resolve quantum jumps in the flux qubit. This is enabled by a readout which discriminates between the readout pointer state distributions to an error below one part in 1000. This, along with the ability to make many successive readouts in a time T1, permits the use of heralding to ensure initialization to a fiducial state, such as the ground state. This method enables us to eliminate errors due to spurious thermal population, increasing the fidelity to 93.9%. Finally, we use heralding to introduce a simple, fast qubit reset protocol without changing the system parameters to induce Purcell relaxation.

•Jan 1, 2012•0 citations
We report measurements on two superconducting flux qubits coupled to a readout superconducting quantum interference device (SQUID). Two on-chip flux bias lines allow independent flux control of any two of the three elements, as illustrated by a two-dimensional qubit flux map. The application of microwaves yields a frequency-flux dispersion curve for 1- and 2-photon driving of the single-qubit excited state, and coherent manipulation of the single-qubit state results in Rabi oscillations and Ramsey fringes. This architecture should be scalable to many qubits and SQUIDs on a single chip.
Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time T Rabi = 78 ns and energy relaxation time T 1 = 315 ns. We found that the value of T Rabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.
A superconducting flux qubit is inductively coupled to a superconducting quantum interference device (SQUID) magnetometer, capacitively shunted to form a 1.294-GHz resonator. The qubit-state-dependent resonator frequency is weakly probed with a microwave signal and detected with a microstrip SQUID amplifier. At a mean resonator occupation n‾=1.5\overline{n}=1.5n=1.5 photons, the readout visibility is increased by a factor of 4.5 over that using a cryogenic semiconductor amplifier. As n‾\overline{n}n is increased from 0.008 to 0.1, no reduction in T1{T}_{1}T1​ is observed, potentially enabling continuous monitoring of the qubit state.
Frequency-selective readout for superconducting qubits opens up the way towards scaling qubit circuits without increasing the number of measurement lines. Here we demonstrate the readout of an array of 7 flux qubits located on the same chip using a single measurement line. Each qubit is placed near an individual λ/4 resonator which, in turn, is coupled to a common microwave transmission line. We performed spectroscopy and coherent manipulation of all qubits and determined their parameters in a single measurement run.
We present experimental results on a microwave scheme for reading out a Josephson phase qubit. A capacitively shunted superconducting quantum interference device (SQUID) is used as a nonlinear resonator which is inductively coupled to the qubit. The flux state of the qubit is detected by measuring the amplitude and phase of a microwave pulse reflected from the SQUID resonator. By this low-dissipative method, the qubit state measurement time is reduced to 25 μs, which is much faster than the conventional readout performed by switching the SQUID to its nonzero dc voltage state. The readout scheme presented here allows for reading out multiple qubits using a single microwave line by employing frequency-division multiplexing.
We have observed coherent time evolution between two quantum states of a superconducting flux qubit comprising three Josephson junctions in a loop. The superposition of the two states carrying opposite macroscopic persistent currents is manipulated by resonant microwave pulses. Readout by means of switching-event measurement with an attached superconducting quantum interference device revealed quantum-state oscillations with high fidelity. Under strong microwave driving, it was possible to induce hundreds of coherent oscillations. Pulsed operations on this first sample yielded a relaxation time of 900 nanoseconds and a free-induction dephasing time of 20 nanoseconds. These results are promising for future solid-state quantum computing.
Though superconducting qubits offer the potential for a scalable quantum computing architecture, the high-fidelity readout necessary to execute practical algorithms has thus far remained elusive. Moreover, achievements toward high fidelity have been accompanied by either long measurement times or demolition of the quantum state. In this dissertation, we address these issues with the novel integration of two ultralow-noise, superconducting amplifiers into separate dispersive flux qubit measurements. We first demonstrate a flux qubit inductively coupled to a 1.294-GHz nonlinear oscillator formed by a capacitively shunted DC SQUID. The frequency of the oscillator is modulated by the state of the qubit and is detected via microwave reflectometry. A microstrip SQUID (Superconducting QUantum Interference Device) amplifier (MSA) is used to increase the sensitivity of the measurement over that of a semiconductor amplifier. In the second experiment, we report measurements of a flux qubit coupled via a shared inductance to a quasi-lumped element 5.78-GHz readout resonator formed by the parallel combination of an interdigitated capacitor and a meander line inductor. The system noise is substantially reduced by a near-quantum-limited Josephson parametric amplifier (paramp).We present measurements of increased fidelity and reduced measurement backaction using the MSA at readout excitation levels as low as one hundredth of a photon in the readout resonator, observing a 4.5-fold increase in the readout visibility. Furthermore, at low readout excitation levels below one tenth of a photon in the readout resonator, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state. Using the paramp, we demonstrate a continuous, high-fidelity readout with sufficient bandwidth and signal-to-noise ratio to resolve quantum jumps in the flux qubit. This is enabled by a readout which discriminates between the readout pointer state distributions to an error below one part in 1000. This, along with the ability to make many successive readouts in a time T1, permits the use of heralding to ensure initialization to a fiducial state, such as the ground state. This method enables us to eliminate errors due to spurious thermal population, increasing the fidelity to 93.9%. Finally, we use heralding to introduce a simple, fast qubit reset protocol without changing the system parameters to induce Purcell relaxation.