Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0311308 · Physical Review Letters

Differential Charge Sensing and Charge Delocalization in a Tunable Double Quantum Dot

L. DiCarlo, H. J. Lynch, Alex C. Johnson, Lilian Childress, K. Crockett, Charles M. Marcus, Micah P. Hanson, Arthur C. Gossard

Published Jun 4, 2004• 191 citations
arXivHTMLPDF

Abstract

We report measurements of a tunable double quantum dot, operating in the quantum regime, with integrated local charge sensors. The spatial resolution of the sensors allows the charge distribution within the double dot system to be resolved at fixed total charge. We use this readout scheme to investigate charge delocalization as a function of temperature and strength of tunnel coupling, demonstrating that local charge sensing can be used to accurately determine the interdot coupling in the absence of transport.

DOI
10.1103/physrevlett.92.226801

Related papers

Single-Electron Delocalization in Hybrid Vertical-Lateral Double Quantum Dots

T. Hatano, Michael P. Stopa, Seigo Tarucha

We used a hybrid vertical-lateral double-dot device, consisting of laterally coupled vertical quantum dots, to measure the interdot tunnel coupling. By using nonlinear transport measurements of "Coulomb diamonds," we showed that an inherent asymmetry in the capacitances of the component dots influences the diamond slopes, thereby allowing for the determination of the dot through which the electron has passed. We used this technique to prepare a delocalized one-electron state and Heitler-London (HL) two-electron state, and we showed that the interdot tunnel coupling, which determines whether HL is the ground state, is tunable. This implies that our device may be useful for implementing two-electron spin entanglement.

Science•Jul 7, 2005•131 citations

Charge Relaxation in a Single-Electron Si/SiGe Double Quantum Dot

Ke Wang, Chris Payette, Yuliya Dovzhenko +2 more

We measure the interdot charge relaxation time T1 of a single electron trapped in an accumulation mode Si/SiGe double quantum dot. The energy level structure of the charge qubit is determined using photon assisted tunneling, which reveals the presence of a low-lying excited state. We systematically measure T1 as a function of detuning and interdot tunnel coupling and show that it is tunable over four orders of magnitude, with a maximum of 45 μs for our device configuration.

arXiv:1304.2640•Physical Review Letters•Jul 22, 2013•83 citations

Fast Charge Sensing of a Cavity-Coupled Double Quantum Dot Using a Josephson Parametric Amplifier

J. Stehlik, Y.-Y. Liu, C. M. Quintana +3 more

Double quantum dots (DQDs), sometimes referred to as ``artificial molecules'', are highly controllable quantum systems that serve as building blocks for spin-based quantum computation. A fast, high-fidelity charge sensor is needed for determining the number of electrons trapped in the DQD, and for spin-state readout. Here the authors integrate a Josephson parametric amplifier into the readout chain, improving the signal to noise ratio by a factor of 2000 and enabling live tuning of the DQD potential well, without the slow, painstaking adjustment of voltages on several electrodes.

arXiv:1502.01283•Physical Review Applied•Jul 27, 2015•120 citations

Manipulation of a Single Charge in a Double Quantum Dot

J. R. Petta, Alex C. Johnson, Charles M. Marcus +2 more

We manipulate a single electron in a fully tunable double quantum dot using microwave excitation. Under resonant conditions, microwaves drive transitions between the (1,0) and (0,1) charge states of the double dot. Local quantum point contact charge detectors enable a direct measurement of the photon-induced change in occupancy of the charge states. From charge sensing measurements, we find T1 approximately 16 ns and a lower bound estimate for T*(2) of 400 ps for the charge two-level system.

arXiv:cond-mat/0408139•Physical Review Letters•Oct 27, 2004•430 citations

Multi-Dimensional Quantum Capacitance of the Two-Site Hubbard Model: The Role of Tunable Interdot Tunneling

Andrea Secchi, Filippo Troiani

Few-electron states confined in quantum-dot arrays are key objects in quantum computing. The discrimination between these states is essential for the readout of a (multi-)qubit state, and can be achieved through a measurement of the quantum capacitance within the gate-reflectometry approach. For a system controlled by several gates, the dependence of the measured capacitance on the direction of the oscillations in the voltage space is captured by the quantum capacitance matrix. Herein, we apply this tool to study a double quantum dot coupled to three gates, which enable the tuning of both the bias and the tunneling between the two dots. Analytical solutions for the two-electron case are derived within a Hubbard model, showing the overall dependence of the quantum capacitance matrix on the applied gate voltages. In particular, we investigate the role of the tunneling gate and reveal the possibility of exploiting interdot coherences in addition to charge displacements between the dots. Our results can be directly applied to double-dot experimental setups, and pave the way for further applications to larger arrays of quantum dots.

Entropy•Dec 31, 2022•4 citations

Monitoring quantum transport: Backaction and measurement correlations

Robert Hussein, Jorge Gómez-García, Sigmund Kohler

We investigate a tunnel contact coupled to a double quantum dot (DQD) and employed as a charge monitor for the latter. We consider both the classical limit and the quantum regime. In the classical case, we derive measurement correlations from conditional probabilities, yielding quantitative statements about the parameter regime in which the detection scheme works well. Moreover, we demonstrate that not only the DQD occupation but also the corresponding current may strongly correlate with the detector current. The quantum-mechanical solution, obtained with a Bloch-Redfield master equation, shows that the backaction of the measurement tends to localize the DQD electrons, and thus significantly reduces the DQD current. Moreover, it provides the effective parameters of the classical treatment. It turns out that already the classical description is adequate for most operating regimes.

arXiv:1407.2803•Physical Review B•Oct 14, 2014•9 citations
We report measurements of a tunable double quantum dot, operating in the quantum regime, with integrated local charge sensors. The spatial resolution of the sensors allows the charge distribution within the double dot system to be resolved at fixed total charge. We use this readout scheme to investigate charge delocalization as a function of temperature and strength of tunnel coupling, demonstrating that local charge sensing can be used to accurately determine the interdot coupling in the absence of transport.
We used a hybrid vertical-lateral double-dot device, consisting of laterally coupled vertical quantum dots, to measure the interdot tunnel coupling. By using nonlinear transport measurements of "Coulomb diamonds," we showed that an inherent asymmetry in the capacitances of the component dots influences the diamond slopes, thereby allowing for the determination of the dot through which the electron has passed. We used this technique to prepare a delocalized one-electron state and Heitler-London (HL) two-electron state, and we showed that the interdot tunnel coupling, which determines whether HL is the ground state, is tunable. This implies that our device may be useful for implementing two-electron spin entanglement.
Double quantum dots (DQDs), sometimes referred to as ``artificial molecules'', are highly controllable quantum systems that serve as building blocks for spin-based quantum computation. A fast, high-fidelity charge sensor is needed for determining the number of electrons trapped in the DQD, and for spin-state readout. Here the authors integrate a Josephson parametric amplifier into the readout chain, improving the signal to noise ratio by a factor of 2000 and enabling live tuning of the DQD potential well, without the slow, painstaking adjustment of voltages on several electrodes.
Few-electron states confined in quantum-dot arrays are key objects in quantum computing. The discrimination between these states is essential for the readout of a (multi-)qubit state, and can be achieved through a measurement of the quantum capacitance within the gate-reflectometry approach. For a system controlled by several gates, the dependence of the measured capacitance on the direction of the oscillations in the voltage space is captured by the quantum capacitance matrix. Herein, we apply this tool to study a double quantum dot coupled to three gates, which enable the tuning of both the bias and the tunneling between the two dots. Analytical solutions for the two-electron case are derived within a Hubbard model, showing the overall dependence of the quantum capacitance matrix on the applied gate voltages. In particular, we investigate the role of the tunneling gate and reveal the possibility of exploiting interdot coherences in addition to charge displacements between the dots. Our results can be directly applied to double-dot experimental setups, and pave the way for further applications to larger arrays of quantum dots.
We investigate a tunnel contact coupled to a double quantum dot (DQD) and employed as a charge monitor for the latter. We consider both the classical limit and the quantum regime. In the classical case, we derive measurement correlations from conditional probabilities, yielding quantitative statements about the parameter regime in which the detection scheme works well. Moreover, we demonstrate that not only the DQD occupation but also the corresponding current may strongly correlate with the detector current. The quantum-mechanical solution, obtained with a Bloch-Redfield master equation, shows that the backaction of the measurement tends to localize the DQD electrons, and thus significantly reduces the DQD current. Moreover, it provides the effective parameters of the classical treatment. It turns out that already the classical description is adequate for most operating regimes.