Submillimeter Heterodyne Detection Using Diffusion Cooled Superconducting Hot-Electron

William R. McGrath, Anders J. Skalare

Published Apr 1, 1995• 0 citations
OpenAlex

Related papers

Diffusion-Cooled Superconducting Hot-Electron Bolometer Heterodyne Mixer at 660 and 800 GHz

Klaus Fiegle, D. Diehl, Karl Jacobs

ESASP•Dec 1, 1996•0 citations

Submillimeter Wave Superconducting Hot-Electron Direct Detectors

Boris S. Karasik, Bertrand Delaet, William R. McGrath +3 more

•Jan 1, 2002•0 citations

Superconducting Hot Electron Bolometer Mixers for Submillimeter Receivers

Anders J. Skalare, William R. McGrath, Bruce Bumble +4 more

•May 10, 1994•0 citations

Noise temperature and IF bandwidth of a 530-GHz heterodyne receiver employing a diffusion-cooled superconducting hot-electron mixer

Anders J. Skalare, William R. McGrath, B. Bumble +4 more

We report on the first heterodyne measurements with a diffusion-cooled hot-electron bolometer mixer in the submillimeter wave band, using a waveguide mixer cooled to 2.2 K. The best receiver noise temperature at a local oscillator frequency of 533 GHz and an intermediate frequency of 1.4 GHz was 650 K (double sideband). The 3 dB IF roll-off frequency was around 1.7 to 1.9 GHz, with a weak dependence on the device bias conditions.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 13, 1995•0 citations

Superconducting hot electron bolometers for terahertz sensing

Matthew O. Reese

Superconducting Hot Electron Bolometers (HEBs) are good candidates for detecting weak signals in the submillimeter or terahertz range. In this thesis work, a novel fabrication method was developed to make two types of niobium HEBs for different applications. HEBs were designed, fabricated, and then characterized at dc, microwave, and THz frequencies. The first type is a diffusion-cooled HEB, made with a short bridge that determines its cooling time. In this thesis, bridges were typically 400 nm long with bandwidths of about 1 GHz. These diffusion-cooled HEBs were developed as part of a collaboration with the University of Arizona (UA), to develop a proof-of-concept heterodyne array submillimeter camera. Devices were fabricated on thin fused quartz and silica substrates for waveguide coupling in the UA system for the astrophysically interesting 345 and 810 GHz atmospheric windows. The goal of this collaboration is to provide a basis of comparison between Nb diffusion-cooled HEB mixers and superconductorinsulator-superconductor mixers at these frequencies. The second type is a phonon-cooled HEB, made with a ∼3 µm long bridge. Its thermal response is dictated by the electron-phonon relaxation time. These devices were developed in collaboration with Prof. C. Schmuttenmaer’s lab in the Yale Chemistry department, Prof. G. Blake at Caltech,

•Jan 1, 2006•7 citations

Superconducting Sensors for Submillimeter Heterodyne Receiver Systems

Henry George LeDuc, B. Bumble, Koko G. Megerian +1 more

•Jan 1, 1996•0 citations
Superconducting Hot Electron Bolometers (HEBs) are good candidates for detecting weak signals in the submillimeter or terahertz range. In this thesis work, a novel fabrication method was developed to make two types of niobium HEBs for different applications. HEBs were designed, fabricated, and then characterized at dc, microwave, and THz frequencies. The first type is a diffusion-cooled HEB, made with a short bridge that determines its cooling time. In this thesis, bridges were typically 400 nm long with bandwidths of about 1 GHz. These diffusion-cooled HEBs were developed as part of a collaboration with the University of Arizona (UA), to develop a proof-of-concept heterodyne array submillimeter camera. Devices were fabricated on thin fused quartz and silica substrates for waveguide coupling in the UA system for the astrophysically interesting 345 and 810 GHz atmospheric windows. The goal of this collaboration is to provide a basis of comparison between Nb diffusion-cooled HEB mixers and superconductorinsulator-superconductor mixers at these frequencies. The second type is a phonon-cooled HEB, made with a ∼3 µm long bridge. Its thermal response is dictated by the electron-phonon relaxation time. These devices were developed in collaboration with Prof. C. Schmuttenmaer’s lab in the Yale Chemistry department, Prof. G. Blake at Caltech,