Noise temperature and IF bandwidth of a 530-GHz heterodyne receiver employing a diffusion-cooled superconducting hot-electron mixer

Anders J. Skalare, William R. McGrath, B. Bumble, Henry George LeDuc, Peter John Burke, A. A. Verheijen, D. E. Prober

Published Oct 13, 1995• 0 citations
Publisher

Abstract

We report on the first heterodyne measurements with a diffusion-cooled hot-electron bolometer mixer in the submillimeter wave band, using a waveguide mixer cooled to 2.2 K. The best receiver noise temperature at a local oscillator frequency of 533 GHz and an intermediate frequency of 1.4 GHz was 650 K (double sideband). The 3 dB IF roll-off frequency was around 1.7 to 1.9 GHz, with a weak dependence on the device bias conditions.

DOI
10.1117/12.224230

Related papers

Large bandwidth and low noise in a diffusion-cooled hot-electron bolometer mixer

Anders J. Skalare, William R. McGrath, B. Bumble +5 more

Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 μm long niobium microbridge with a superconducting transition temperature of 5 K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection with intermediate frequencies (if) of several GHz. A Y-factor response of 1.15 dB has been obtained at an if of 1.4 GHz with 77 and 295 K loads, indicating a receiver noise temperature of 650 K DSB. The −3 dB rolloff in the if response occurs at 1.7 GHz.

Applied Physics Letters•Mar 11, 1996•73 citations

Receiver measurements at 1267 GHz using a diffusion-cooled superconducting transition-edge bolometer

Anders J. Skalare, William R. McGrath, B. Bumble +1 more

We report receiver noise temperature measurements using a quasioptically coupled diffusion-cooled hot-electron bolometer mixer at a local oscillator frequency of 1267 GHz, and an intermediate frequency of 1.4 GHz. A best double-sideband (DSB) receiver noise temperature of 1880 K was measured, with an estimated mixer noise of 945 K (DSB), and a conversion efficiency including coupling losses of -19 dB (DSB). The coupled local oscillator power requirement for this device is estimated at roughly 6 nW. The mixer noise temperature is less than twice that measured earlier in a waveguide receiver at 530 GHz, which shows that the sensitivity of this type of mixer does not degrade sharply with increasing frequency in this regime.

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•25 citations

Noise and Bandwidth Measurements of Diffusion-Cooled Nb Hot-Electron Bolometer Mixers at Frequencies Above the Superconductive Energy Gap

Rolf A. Wyss, Boris S. Karasik, William R. McGrath +2 more

Diffusion-cooled Nb hot-electron bolometer (HEB) mixers have the potential to simultaneously achieve high intermediate frequency (IF) bandwidths and low mixer noise temperatures for operation at THz frequencies (above the superconductive gap energy). We have measured the IF signal bandwidth at 630 GHz of Nb devices with lengths L = 0.3, 0.2, and 0.1 micrometer in a quasioptical mixer configuration employing twin-slot antennas. The 3-dB EF bandwidth increased from 1.2 GHz for the 0.3 gm long device to 9.2 GHz for the 0.1 gm long device. These results demonstrate the expected 1/L squared dependence of the IF bandwidth at submillimeter wave frequencies for the first time, as well as the largest EF bandwidth obtained to date. For the 0.1 gm device, which had the largest bandwidth, the double sideband (DSB) noise temperature of the receiver was 320-470 K at 630 GHz with an absorbed LO power of 35 nW, estimated using the isothermal method. A version of this mixer with the antenna length scaled for operation at 2.5 THz has also been tested. A DSB receiver noise temperature of 1800 plus or minus 100 K was achieved, which is about 1,000 K lower than our previously reported results. These results demonstrate that large EF bandwidth and low-noise operation of a diffusion-cooled HEB mixer is possible at THz frequencies with the same device geometry.

Softwaretechnik-Trends•Jan 1, 1999•20 citations

A heterodyne receiver at 533 GHz using a diffusion-cooled superconducting hot electron bolometer mixer

Anders J. Skalare, William R. McGrath, B. Bumble +4 more

This paper describes heterodyne measurements at 533 GHz using a novel superconducting hot electron bolometer in a waveguide mixer block. The bolometer is a thin (10 nm) and narrow (0.1 /spl mu/m) strip of niobium with a length of less than half a micron and a critical temperature of approximately 5.5 K. The short length ensures that diffusion dominates over electron-phonon interaction as a cooling mechanism for the hot electrons, thus allowing heterodyne detection with intermediate frequencies of several GHz. A Y-factor response of 1.15 dB has been obtained at an intermediate frequency of 1.4 GHz with hot/cold load temperatures of approximately 295/77 K, indicating a receiver noise temperature around 650 K DSB. The IF response extends up to at least 2 GHz and possibly higher.>

IEEE Transactions on Applied Superconductivity•Jun 1, 1995•32 citations

Diffusion-cooled superconducting hot electron bolometer heterodyne mixer between 630 and 820 GHz

Klaus Fiegle, D. Diehl, Karl Jacobs

We report on heterodyne mixing experiments between 630-820 GHz using a diffusion-cooled superconducting hot electron bolometer at intermediate frequencies from 1-2 GHz. The niobium bolometer which is cooled by diffusion of the hot electrons into a normal conductor has dimensions of 0.3 /spl mu/m/spl times/0.15 /spl mu/m and was fabricated at KOSMA with a two-step electron beam lithography process. The film thickness of the device is 30 nm with T/sub c/ of 6.1 K and /spl Delta/T/sub c/ of 0.7 K. The mixing experiments are performed with a tunerless waveguide mixer block previously used for very low-noise SIS receivers. At a physical temperature of 2.2 K, receiver noise temperatures at 666 GHz are 1500 K at 1.0 GHz intermediate frequency, increasing rapidly above 1.5 GHz. The dissipated local oscillator power is evaluated to be 65-90 nW.

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•13 citations

Low noise NbN lattice-cooled superconducting hot-electron bolometric mixers at submillimeter wavelengths

Jonathan H. Kawamura, R. Blundell, Edward Tong +4 more

Lattice-cooled superconducting hot-electron bolometric mixers are used in a submillimeter-wave waveguide heterodyne receiver. The mixer elements are niobium nitride film with 3.5 nm thickness and ∼10 μm2 area. The local oscillator power for optimal performance is estimated to be 0.5 μW, and the instantaneous bandwidth is 2.2 GHz. At an intermediate frequency centered at 1.4 GHz with 200 MHz bandwidth, the double sideband receiver noise temperature is 410 K at 430 GHz. The receiver has been used to detect molecular line emission in a laboratory gas cell.

Applied Physics Letters•Mar 24, 1997•40 citations
We report on the first heterodyne measurements with a diffusion-cooled hot-electron bolometer mixer in the submillimeter wave band, using a waveguide mixer cooled to 2.2 K. The best receiver noise temperature at a local oscillator frequency of 533 GHz and an intermediate frequency of 1.4 GHz was 650 K (double sideband). The 3 dB IF roll-off frequency was around 1.7 to 1.9 GHz, with a weak dependence on the device bias conditions.
Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 μm long niobium microbridge with a superconducting transition temperature of 5 K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection with intermediate frequencies (if) of several GHz. A Y-factor response of 1.15 dB has been obtained at an if of 1.4 GHz with 77 and 295 K loads, indicating a receiver noise temperature of 650 K DSB. The −3 dB rolloff in the if response occurs at 1.7 GHz.
We report receiver noise temperature measurements using a quasioptically coupled diffusion-cooled hot-electron bolometer mixer at a local oscillator frequency of 1267 GHz, and an intermediate frequency of 1.4 GHz. A best double-sideband (DSB) receiver noise temperature of 1880 K was measured, with an estimated mixer noise of 945 K (DSB), and a conversion efficiency including coupling losses of -19 dB (DSB). The coupled local oscillator power requirement for this device is estimated at roughly 6 nW. The mixer noise temperature is less than twice that measured earlier in a waveguide receiver at 530 GHz, which shows that the sensitivity of this type of mixer does not degrade sharply with increasing frequency in this regime.
Diffusion-cooled Nb hot-electron bolometer (HEB) mixers have the potential to simultaneously achieve high intermediate frequency (IF) bandwidths and low mixer noise temperatures for operation at THz frequencies (above the superconductive gap energy). We have measured the IF signal bandwidth at 630 GHz of Nb devices with lengths L = 0.3, 0.2, and 0.1 micrometer in a quasioptical mixer configuration employing twin-slot antennas. The 3-dB EF bandwidth increased from 1.2 GHz for the 0.3 gm long device to 9.2 GHz for the 0.1 gm long device. These results demonstrate the expected 1/L squared dependence of the IF bandwidth at submillimeter wave frequencies for the first time, as well as the largest EF bandwidth obtained to date. For the 0.1 gm device, which had the largest bandwidth, the double sideband (DSB) noise temperature of the receiver was 320-470 K at 630 GHz with an absorbed LO power of 35 nW, estimated using the isothermal method. A version of this mixer with the antenna length scaled for operation at 2.5 THz has also been tested. A DSB receiver noise temperature of 1800 plus or minus 100 K was achieved, which is about 1,000 K lower than our previously reported results. These results demonstrate that large EF bandwidth and low-noise operation of a diffusion-cooled HEB mixer is possible at THz frequencies with the same device geometry.
This paper describes heterodyne measurements at 533 GHz using a novel superconducting hot electron bolometer in a waveguide mixer block. The bolometer is a thin (10 nm) and narrow (0.1 /spl mu/m) strip of niobium with a length of less than half a micron and a critical temperature of approximately 5.5 K. The short length ensures that diffusion dominates over electron-phonon interaction as a cooling mechanism for the hot electrons, thus allowing heterodyne detection with intermediate frequencies of several GHz. A Y-factor response of 1.15 dB has been obtained at an intermediate frequency of 1.4 GHz with hot/cold load temperatures of approximately 295/77 K, indicating a receiver noise temperature around 650 K DSB. The IF response extends up to at least 2 GHz and possibly higher.>
We report on heterodyne mixing experiments between 630-820 GHz using a diffusion-cooled superconducting hot electron bolometer at intermediate frequencies from 1-2 GHz. The niobium bolometer which is cooled by diffusion of the hot electrons into a normal conductor has dimensions of 0.3 /spl mu/m/spl times/0.15 /spl mu/m and was fabricated at KOSMA with a two-step electron beam lithography process. The film thickness of the device is 30 nm with T/sub c/ of 6.1 K and /spl Delta/T/sub c/ of 0.7 K. The mixing experiments are performed with a tunerless waveguide mixer block previously used for very low-noise SIS receivers. At a physical temperature of 2.2 K, receiver noise temperatures at 666 GHz are 1500 K at 1.0 GHz intermediate frequency, increasing rapidly above 1.5 GHz. The dissipated local oscillator power is evaluated to be 65-90 nW.
Lattice-cooled superconducting hot-electron bolometric mixers are used in a submillimeter-wave waveguide heterodyne receiver. The mixer elements are niobium nitride film with 3.5 nm thickness and ∼10 μm2 area. The local oscillator power for optimal performance is estimated to be 0.5 μW, and the instantaneous bandwidth is 2.2 GHz. At an intermediate frequency centered at 1.4 GHz with 200 MHz bandwidth, the double sideband receiver noise temperature is 410 K at 430 GHz. The receiver has been used to detect molecular line emission in a laboratory gas cell.