Analysis of Quantum Information Test-Bed by Parametric Down-Converted Photons Interference Measurement

W. To

Published Aug 1, 2005• 0 citations
OpenAlex

Abstract

Quantum optical experiments require all the components involved to be extremely stable relative to each other. The stability can be measured by using an interferometric experiment. A pair of coherent photons produced by parametric down-conversion could be chosen to be orthogonally polarized initially. By rotating the polarization of one of the wave packets, they can be recombined at a beam splitter such that interference will occur. Theoretically, the interference will create four terms in the wave function. Two terms with both photons going to the same detector, and two terms will have the photons each going to different detectors. However, the latter will cancel each other out, thus no photons will arrive at the two detectors simultaneously under ideal conditions. The stability Of the test-bed can then be inferred by the dependence of coincidence count on the rotation angle.

Related papers

Two-Photon Interference Experiment in a Mach-Zehnder Interferometer

Taesoo Kim, Heonoh Kim, Jeong-Hoon Ko +1 more

A two-photon interference experiment is presented in which an entangled pair of photons generated from a parametric down-conversion was incident on two input ports of a Mach-Zehnder interferometer. The experiment was carried out using two photon coincidence detection with two detectors at the two output ports of the interferometer. The measured coincidence counts exhibit an interference effect with visibility of 0.75 at simultaneous inputs and 0.38 at inputs with different arrival times according to the degree of photon number entanglement.

Journal of the Optical Society of Korea•Jun 1, 2003•11 citations

Optical Bell-state analysis in the coincidence basis

Stephen Patrick Walborn, W. A. T. Nogueira, Sebastião Pádua +1 more

Many quantum information protocols require a Bell-state measurement of entangled systems. Most optical Bell-state measurements utilize two-photon interference at a beam splitter. By creating polarization-entangled photons with spontaneous parametric down-conversion using a first-order Hermite-Gaussian pump beam, we invert the usual interference behavior and perform an incomplete Bell-state measurement in the coincidence basis. We discuss the possibility of a complete Bell-state measurement in the coincidence basis using hyperentangled states ( Phys. Rev. A, 58 (1998) R2623).

arXiv:quant-ph/0212058•Europhysics Letters (EPL)•Apr 1, 2003•35 citations

Optical Absorption Measurements with Parametric Down-Converted Photons

Zhi Gao Zhao, Kent A. Meyer, William Barclay Whitten +1 more

It has been known for some time that correlated detection of pairs of photons generated by parametric down-conversion can eliminate several sources of error that occur in single-beam measurements. In the correlated photon measurements, the down-converted photons are separated into two beams with one photon of a pair in each beam. The absolute detection efficiency of a detector in one beam can be determined from the count rate of a detector in the other beam and the coincidence rate for the two detectors. These ideas can be used to measure the optical absorbance of a sample placed in front of one of the detectors. Errors due to stray light and dark counts are substantially reduced and fluctuations in pump intensity largely eliminated.

Analytical Chemistry•Aug 26, 2008•3 citations

Photon localization In parametric downconversion

John G. Rarity, P. R. Tapster

Quantum mechanical models of beam splitters1 predict interesting fourth-order interference effects when nonclassical light is used. If indistinguishable one-photon states are simultaneously input into each port of a 50/50 beam splitter, the theory predicts that each output will contain either two photons or none. A naive (particle) theory would predict a mixture of two’s and one’s. The required |1,1〉 photon state can be selected in nondegenerate parametric downconversion experiments by photon-counting coincidence detection. The disappearance of this coincidence after a beam splitter has recently been studied,1-2 and the range of path length differences over which the effect can be seen is related by Fourier transform to the photon bandwidth. In our work the bandwidth is not limited by external filters, and we have developed a theory which relates the measured photon length to the geometry of the apparatus and the detailed phase matching conditions at the parametric crystal. This theory of phase matching viewed through a beam splitter produces some unexpected results when the beam splitter is tilted and when large aperture detectors are considered.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Experiment on nonclassical fourth-order interference

Z. Y. Ou, X. Y. Zou, L. J. Wang +1 more

A new fourth-order interference experiment has been carried out and analyzed theoretically in classical and in quantum terms. Two photons produced in the process of parametric down-conversion provide the two inputs to a Mach-Zehnder type of interferometer, while two photodetectors coupled to a coincidence counter measure the output. The coincidence rate, after subtraction of accidentals, exhibits a cosine variation with the optical path difference, in agreement with quantum mechanics, but in disagreement with a classical analysis. By contrast, when two coherent light beams from a He:Ne laser are used as inputs to the interferometer, no fourth-order interference is observed.

Physical Review A•Sep 1, 1990•117 citations

Fourth-order interference in parametric downconversion

John G. Rarity, P. R. Tapster

A two-photon state can be selected by coincidence detection of photon pairs created in parametric downconversion. We demonstrate a reduction in the coincidence-count rate when pairs of photons are combined in a beam splitter. This reduction occurs only when photon wave functions overlap and can permit accurate (subpicosecond) relative timing measurements. We relate the width of the coincidence reduction to the bandwidth of the downconverted light and thence to the detailed phase-matching conditions in the parametric downconversion crystal. We also demonstrate that the loss of coincidences is associated with an increased probability of detection of photon pairs in each output of the beam splitter.

Journal of the Optical Society of America B•Jun 1, 1989•91 citations
Quantum optical experiments require all the components involved to be extremely stable relative to each other. The stability can be measured by using an interferometric experiment. A pair of coherent photons produced by parametric down-conversion could be chosen to be orthogonally polarized initially. By rotating the polarization of one of the wave packets, they can be recombined at a beam splitter such that interference will occur. Theoretically, the interference will create four terms in the wave function. Two terms with both photons going to the same detector, and two terms will have the photons each going to different detectors. However, the latter will cancel each other out, thus no photons will arrive at the two detectors simultaneously under ideal conditions. The stability Of the test-bed can then be inferred by the dependence of coincidence count on the rotation angle.
A two-photon interference experiment is presented in which an entangled pair of photons generated from a parametric down-conversion was incident on two input ports of a Mach-Zehnder interferometer. The experiment was carried out using two photon coincidence detection with two detectors at the two output ports of the interferometer. The measured coincidence counts exhibit an interference effect with visibility of 0.75 at simultaneous inputs and 0.38 at inputs with different arrival times according to the degree of photon number entanglement.
Many quantum information protocols require a Bell-state measurement of entangled systems. Most optical Bell-state measurements utilize two-photon interference at a beam splitter. By creating polarization-entangled photons with spontaneous parametric down-conversion using a first-order Hermite-Gaussian pump beam, we invert the usual interference behavior and perform an incomplete Bell-state measurement in the coincidence basis. We discuss the possibility of a complete Bell-state measurement in the coincidence basis using hyperentangled states ( Phys. Rev. A, 58 (1998) R2623).
It has been known for some time that correlated detection of pairs of photons generated by parametric down-conversion can eliminate several sources of error that occur in single-beam measurements. In the correlated photon measurements, the down-converted photons are separated into two beams with one photon of a pair in each beam. The absolute detection efficiency of a detector in one beam can be determined from the count rate of a detector in the other beam and the coincidence rate for the two detectors. These ideas can be used to measure the optical absorbance of a sample placed in front of one of the detectors. Errors due to stray light and dark counts are substantially reduced and fluctuations in pump intensity largely eliminated.
Quantum mechanical models of beam splitters1 predict interesting fourth-order interference effects when nonclassical light is used. If indistinguishable one-photon states are simultaneously input into each port of a 50/50 beam splitter, the theory predicts that each output will contain either two photons or none. A naive (particle) theory would predict a mixture of two’s and one’s. The required |1,1〉 photon state can be selected in nondegenerate parametric downconversion experiments by photon-counting coincidence detection. The disappearance of this coincidence after a beam splitter has recently been studied,1-2 and the range of path length differences over which the effect can be seen is related by Fourier transform to the photon bandwidth. In our work the bandwidth is not limited by external filters, and we have developed a theory which relates the measured photon length to the geometry of the apparatus and the detailed phase matching conditions at the parametric crystal. This theory of phase matching viewed through a beam splitter produces some unexpected results when the beam splitter is tilted and when large aperture detectors are considered.
A new fourth-order interference experiment has been carried out and analyzed theoretically in classical and in quantum terms. Two photons produced in the process of parametric down-conversion provide the two inputs to a Mach-Zehnder type of interferometer, while two photodetectors coupled to a coincidence counter measure the output. The coincidence rate, after subtraction of accidentals, exhibits a cosine variation with the optical path difference, in agreement with quantum mechanics, but in disagreement with a classical analysis. By contrast, when two coherent light beams from a He:Ne laser are used as inputs to the interferometer, no fourth-order interference is observed.
A two-photon state can be selected by coincidence detection of photon pairs created in parametric downconversion. We demonstrate a reduction in the coincidence-count rate when pairs of photons are combined in a beam splitter. This reduction occurs only when photon wave functions overlap and can permit accurate (subpicosecond) relative timing measurements. We relate the width of the coincidence reduction to the bandwidth of the downconverted light and thence to the detailed phase-matching conditions in the parametric downconversion crystal. We also demonstrate that the loss of coincidences is associated with an increased probability of detection of photon pairs in each output of the beam splitter.